Print Page as PDF
DBIA5994 ICR (5994)

DBIA5994    ICR (5994)

Name Value
NUMBER 5994
IA # 5994
DATE CREATED 2013/07/29
CUSTODIAL PACKAGE IMAGING
USAGE Private
TYPE Routine
DBIC APPROVAL STATUS APPROVED
ROUTINE MAGT7MA
NAME DBIA5994
GENERAL DESCRIPTION
VistA Imaging gives permission to Laboratory Package to
call CANCEL^MAGT7MA, EDIT^MAGT7MA, NEW^MAGT7MA, REPORT^MAGT7MA .  These calls
create VistA Imaging HL7 DICOM PACS messages pertain to Anatomic Pathology
order updates. The messages are stored in PACS MESSAGE file (#2006.5) and are
processed by VistA Imaging DICOM Text gateway.
STATUS Active
KEYWORDS MAGT7MA
DURATION Till Otherwise Agreed
ID MAGT7MA
COMPONENT/ENTRY POINT
COMPONENT/ENTRY POINT COMPONENT DESCRIPTION VARIABLES
CANCEL
Creates HL7 order message for a cancelled order.
VARIABLES TYPE VARIABLES DESCRIPTION
LRDFN Input
This is the LRDFN field (#.01) from the patient's
record in the LAB DATA file (#63).
LRSS Input
The accession area for the record in the LAB DATA
file (#63): "CY", "EM", or "SP".
LRI Input
The inverse DATE/TIME SPECIMEN TAKEN (sub-field #.01)
of SURGICAL PATHOLOGY field (#8), CYTOPATHOLOGY field (#9) or EM field (#2) of
the LAB DATA file (#63).
EDIT
Creates HL7 order message for accession modification.

VARIABLES TYPE VARIABLES DESCRIPTION
LRDFN Input
This is the LRDFN field (#.01) from the patient's
record in the LAB DATA file (#63).
LRI Input
The inverse DATE/TIME SPECIMEN TAKEN (sub-field #.01)
of SURGICAL PATHOLOGY field (#8), CYTOPATHOLOGY field (#9) or EM field (#2) of
the LAB DATA file (#63).
LRSS Input
The accession area for the record in the LAB DATA
file (#63): "CY", "EM", or "SP".
MAGNEWCASE Input
This variable must be newed and set to 1 during
creation of a new accession.
NEW
Creates HL7 order message for a new accession.
VARIABLES TYPE VARIABLES DESCRIPTION
LRDFN Input
This is the LRDFN field (#.01) from the patient's
record in the LAB DATA file (#63).
LRSS Input
The accession area for the record in the LAB DATA
file (#63): "CY", "EM", or "SP".
LRI Input
The inverse DATE/TIME SPECIMEN TAKEN (sub-field #.01)
of SURGICAL PATHOLOGY field (#8), CYTOPATHOLOGY field (#9) or EM field (#2) of
the LAB DATA file (#63).
REPORT
Creates HL7 order message for an electronically
signed report.
VARIABLES TYPE VARIABLES DESCRIPTION
LRDATA(1) Input
The inverse DATE/TIME SPECIMEN TAKEN (sub-field #.01)
of SURGICAL PATHOLOGY field (#8), CYTOPATHOLOGY field (#9) or EM field (#2) of
the LAB DATA file (#63).
LRSS Input
The accession area for the record in the LAB DATA
file (#63): "CY", "EM", or "SP".
LRDFN Input
This is the LRDFN field (#.01) from the patient's
record in the LAB DATA file (#63).
LRSF Input
Sub-file number for the accession area: 63.09, 63.02,
or 63.08
SUBSCRIBING PACKAGE
SUBSCRIBING PACKAGE SUBSCRIBING DETAILS
LAB SERVICE
Laboratory package will call VistA Imaging routine to
generate HL7 DICOM PACS messages.
If event driver protocols, related to laboratory order updates, are available
in the future this ICR can be retired after VistA Imaging subscribes to the
protocols.
DATE ACTIVATED 2013/09/27