Print Page as PDF
CONNECT RADIOLOGY EXAM TO VISIT ICR (7186)

CONNECT RADIOLOGY EXAM TO VISIT    ICR (7186)

Name Value
NUMBER 7186
IA # 7186
FILE NUMBER 70
DATE CREATED 2020/07/20
CUSTODIAL PACKAGE RADIOLOGY/NUCLEAR MEDICINE
USAGE Private
TYPE File
DBIC APPROVAL STATUS APPROVED
NAME CONNECT RADIOLOGY EXAM TO VISIT
GLOBAL REFERENCE
GLOBAL REFERENCE FIELD NUMBER
RADPT(D0,'DT',D1,'P')
FIELD NUMBER ACCESS FIELD DESCRIPTION FIELD NAME LOCATION
27 Both R/W w/Fileman
Pointer to Visit file #9000010.
VISIT 70.03;27
STATUS Active
KEYWORDS
  • RADIOLOGY EXAM
  • PCE VISIT
DURATION Till Otherwise Agreed
SUBSCRIBING PACKAGE
SUBSCRIBING PACKAGE SUBSCRIBING DETAILS
PCE PATIENT CARE ENCOUNTER
The PCE utility PXQ PRIMARY PROVIDER REPAIR searches
for encounters that do not have a primary provider and when one is found tries
to set the primary provider. In some cases, an occasion of service created by
Radiology may not have been linked to the corresponding Radiology Exam, data
element: 70.03, 27. In this situation, the utility will work to establish the
link by matching the patient's Exam Date and Time to the Visit Date and Time,
the Radiology Imaging Location to the Visit's Hospital Location, and the
Radiology Procedure to one of the Procedures for the occasion of service. If
all of these conditions are met, it is considered a match and PCE sets data
element 70.03, 27 to the Visit pointer using FileMan.

This will be effective with patch PX*1*211.
DATE ACTIVATED 2020/07/21