Print Page as PDF
EXAM LOCK CHECK ICR (7402)

EXAM LOCK CHECK    ICR (7402)

Name Value
NUMBER 7402
IA # 7402
DATE CREATED 2023/01/05
CUSTODIAL PACKAGE ISI IMAGING
USAGE Private
TYPE Routine
DBIC APPROVAL STATUS APPROVED
ROUTINE MAGJLS2B
NAME EXAM LOCK CHECK
GENERAL DESCRIPTION
The ISI Rad Client application is a plug-in replacement
for VistA Imaging's VistARad client. ISI Rad uses all of the existing VistA
Imaging Server software (RPC calls, routines, files, etc.) in the same way as
VistARad. In some cases, to support new features that VistARad does not have,
new ISI Server software uses many of the same subroutines and files in the
same manner as VistARad; session initialization; fetching exam info and image
info; exam locking; exam list data management; etc.

ISI Rad ISI*1.1*110 provides a Report Entry Function within the ISI Rad
radiology workstation client application. When the case of interest is
selected, the program must determine the current lock status of the exam to
allow or deny access to report updating by the current user.

Revision: Added 11/16/23: This ICR was originally set-up for ISI IMAGING to be
a subscriber to an IMAGING Routine. MAGJ is now excluded from the IMAGING
package and has been added to the ISI IMAGING package as an additional prefix.
As a result ISI IMAGING is both the Custodian and Subscriber. Though this ICR
is no longer needed, the decision was made to leave the ICR in place for
historical purposes.
STATUS Active
KEYWORDS
  • ISI Rad
  • VistARad
  • VistARad COTS
  • ISI*1.1*110
DURATION Till Otherwise Agreed
ID MAGJLS2B
COMPONENT/ENTRY POINT
COMPONENT/ENTRY POINT COMPONENT DESCRIPTION VARIABLES
CHKLOCK
This function returns the initials of the locking
user, and a truth flag that indicates if the locking user is the same as the
logon user.
VARIABLES TYPE VARIABLES DESCRIPTION
RARPT Input
Radiology Report file pointer
DAYCASE Input
Radiology accession number
XX Output
User Initials ^ Truth flag
SUBSCRIBING PACKAGE ISI IMAGING
DATE ACTIVATED 2023/03/03