Print Page as PDF
MAG VISTARAD SITE PARAMETERS (#2006.69) ICR (7410)

MAG VISTARAD SITE PARAMETERS (#2006.69)    ICR (7410)

Name Value
NUMBER 7410
IA # 7410
FILE NUMBER 2006.69
GLOBAL ROOT MAG(2006.69
DATE CREATED 2023/01/05
CUSTODIAL PACKAGE IMAGING
USAGE Private
TYPE File
DBIC APPROVAL STATUS APPROVED
NAME MAG VISTARAD SITE PARAMETERS (#2006.69)
GENERAL DESCRIPTION
The ISI Rad CLIENT application is a plug-in replacement
for VistA Imaging's VistARad client. ISI Rad uses all of the existing VistA
Imaging SERVER software (RPC calls, routines, files, etc.) in the same way as
VistARad. In some cases, to support new features that VistARad does not have,
new ISI SERVER software uses many of the same subroutines and files in the
same manner as VistARad: session initialization; fetching Exam info and Image
info; Exam Locking; Exam List data management; etc.


VistA Imaging gives permission to ISI Imaging to read and update file MAG
VISTARAD SITE PARAMETERS (#2006.69), which contains control data for managing
various logic switches in VistARad (e.g., enable/disable a feature).
GLOBAL REFERENCE
GLOBAL REFERENCE FIELD NUMBER
MAG(2006.69,D0,1)
FIELD NUMBER ACCESS FIELD DESCRIPTION FIELD NAME LOCATION
20 Read w/Fileman
The Unread lists show a column, PRIORITY, that is
typically used as a sort item for the list. Four values are possible (from the
Radiology Exam order, file 75.1).  This field allows the site to define the
preferred sort ordering for these 4 values.  The default order is: Stat,
Urgent, Pre-op, Routine To achieve this ordering, the value for this field
would be specified: S,U,P,R Any sequence of these 4 letters may be defined,
and then will be used by the list program.
UNREAD LIST PRIORITY SEQ 1;E1,245
MAG(2006.69,D0,ISI)
FIELD NUMBER ACCESS FIELD DESCRIPTION FIELD NAME LOCATION
101 Read w/Fileman
This feature allows an exam to be assigned to a specific
Radiologist, or Radiology Tech, for interpretation or follow-up.  This feature
works only if ISI's "Rad Tech Tool" has been installed and configured at the
site.
ENABLE ASSIGN EXAMS FEATURE? ISI;1
102 Read w/Fileman
The Dynamic Query feature, and all supporting program
logic and functionality, shall be enabled only if this field has a value =
"Y".
ENABLE DYNAMIC QUERY FEATURE? ISI;2
103 Read w/Fileman
To prevent dynamic query compiles processing very large
result sets, this value may be defined to abort a query that exceeds the
number specified here.
DYNAMIC QUERY RECORD LIMIT ISI;3
104 Read w/Fileman
If enabled, this feature counts the frequency of use of
each of the exam lists.  The data is aggregated weekly by site.  These
statistics may be viewed by using the PRINT EXAM LIST STATISTICS menu option.
ENABLE EXAM LIST STATISTICS? ISI;4
105 Direct Global R/W & w/Fileman
The Revision-2 modifications remove two obsolete exam
lists from the Manager's top tab row; in their place the Assigned-UNREAD and
Assigned-WAITING tab entries are inserted ("Level-1").  "Level-2" also removes
the Background compile of RECENT exams from server-side processing, so the
option "MAGJ SCHED RECENT LIST COMPILE" no longer needs to be defined in
Taskman.  The obsolete exam lists are "Recent", and "All Active Exams"; these
are still accessible on the Custom tab, if desired.
ENABLE MANAGER REV-2 ISI;5
106 Read w/Fileman
Enter a value to limit how many days back the dynamic
query compile may go.  This will prevent the user from entering a Study From
Date value earlier than "Today" minus the value you enter here.
DYNAMIC QUERY DAYS LIMIT ISI;106
107 Read w/Fileman
In the typical Radiology workflow, dictation/report entry
occurs for exams after images have been acquired. In some circumstances it is
desirable to initiate a report entry session PRIOR to image acquisition.
Ultrasound workflow is the notable example for this.  To support this, a
reserved EXAMINATION STATUS value must be defined, having a specific VISTARAD
CATEGORY value, "Ready for Interpretation",  that is defined to enable this
alternate workflow. This Examination Status value must have an ORDER that
sequences it between the WAITING FOR EXAM status and the EXAMINED status.
Enter the IMAGING TYPE value for which you want to enable this feature. This
must align with the IMAGING TYPE for which the Examination Status value is
being defined.
READY FOR INTERP IMAGING TYPE ISI;7
108 Read w/Fileman
A reserved value defined in the CAMERA/EQUIP/RM file
should be defined for triggering the Exam Status to advance from the WAITING
FOR EXAM status to the status defined having the VISTARAD CATEGORY value,
"Ready for Interpretation".  Enter the reserved CAMERA/EQUIP/RM value here.
READY FOR INTERP TRIGGER VALUE ISI;8
109 Read w/Fileman
This feature allows any ISI Rad user to enter and/or view
notes related to the exam.  These notes are displayed within the ISI Rad
application only, appended to either the exam Report or Requisition.
ENABLE NOTES FEATURE? ISI;9
110 Read w/Fileman
This option allows the user to select the "ISI Rad"
Dictation setting, which provides the user a way to manually enter Radiology
reports in a ISI Rad data entry form. The reports are stored using the
Radiology HL7 interface. This option works only if the requisite Radiology
package programs and HL7 configurations have been installed and configured at
the site.
ENABLE ISIRad DICTATION OPTION ISI;10
STATUS Active
KEYWORDS
  • ISI Rad
  • VistARad
  • VistARad COTS
  • ISI*1.1*110
DURATION Till Otherwise Agreed
ID MAG(2006.69
SUBSCRIBING PACKAGE
SUBSCRIBING PACKAGE SUBSCRIBING DETAILS
ISI IMAGING
VistA Imaging gives permission to ISI Rad to read and
update file MAG VISTARAD SITE PARAMETERS (#2006.69), which contains control
data for managing various logic switches in VistARad (e.g., enable/disable a
feature).

ISI Rad ISI*1.1*110 provides some new features, some of which are optional.
The application needs to make use of pre-existing mechanisms used by VistARad
for managing various logic switches in ISI Rad (e.g., enable/disable
features).
DATE ACTIVATED 2023/03/07