GENERAL DESCRIPTION |
The Laboratory package requests agreement from the VA FileMan package to edit
the Package file (9.4) during the init process for Laboratory Version 5.2.
There are two sets of inits distributed with Lab V 5.2. The LR inits are the
primary inits for the release. The LA inits are for the Automated Instruments
part of the release. The LA inits are only run when the site is installing
this version in a virgin account. There are directions in the installation
guide telling the site NOT to run the inits if they overlaying version 5.2
over version 5.1. The Package file entry for Automated Instruments needs to
be updated to version 5.2, but because the inits are not run, the Package file
will not get updated.
We request permission to use ^DIE and ^DICN to update the following fields in
the AUTOMATED LAB INSTRUMENTS entry in the PACKAGE file.
VERSION (field #22, add a multiple entry)
VERSION (field #.01, sub field of #22)
DATE DISTRIBUTED (field #1, sub field of #22)
DATE INSTALLED AT THIS SITE (field #2, sub field of #22)
CURRENT VERSION (field #13)
This is a one-time request for this release of Laboratory Version 5.2.
|