LA7SM2A ;DALOI/JMC - Shipping Manifest Options ;Oct 4, 2006
;;5.2;AUTOMATED LAB INSTRUMENTS;**74**;Sep 27, 1994;Build 229
;
; Continuation of LA7SM2
;
INFOEE ; Required Info Enter/Edit
;
; Called by LA7SM2
;
N DIR,DIROUT,DIRUT,DTOUT,DUOUT,LA7CDT,LA7I,LA7INFO,LA7J,LA7RINFO,LA7TCNT,LA7X,LA7Y,X,Y
;
D SEL^LA7SM
I LA7QUIT Q
;
S (LA7I,LA7TCNT)=0
F S LA7I=$O(^LAHM(62.8,+LA7SM,10,"UID",LA7UID,LA7I)) Q:'LA7I D
. F LA7J=0,1,2 S LA7I(LA7J)=$G(^LAHM(62.8,+LA7SM,10,LA7I,LA7J))
. I $P(LA7I(0),"^",8)=0 Q ; Previously "removed".
. I $P(LA7I(0),"^",8),$P(LA7I(0),"^",8)'=1 S LA7QUIT="1^Accession not pending shipment" Q ; Not pending shipment
. S LA7TCNT=LA7TCNT+1
. F LA7J=1,4 I $P(LA7I(1),"^",LA7J) D
. . I '$P(LA7I(1),"^",LA7J+2) Q ; No units specified
. . S LA7X=$S(LA7J=1:1.11,LA7J=4:1.21,1:0)
. . S LA7RINFO(LA7X)=$P(LA7I(1),"^",LA7J+1) ; Value
. . S $P(LA7RINFO(LA7X),"^",2)=$P(LA7I(1),"^",LA7J+2) ; Units
. . S LA7RINFO(LA7X,LA7I)=LA7RINFO(LA7X)_"^"_$P(LA7I(0),"^",2)
. F LA7J=1,4,8 I $P(LA7I(2),"^",LA7J) D
. . I '($S(LA7J=4:$P(LA7I(2),"^",7),1:$P(LA7I(2),"^",LA7J+2))) Q ; No units specified.
. . S LA7X=$S(LA7J=1:2.11,LA7J=4:2.21,LA7J=8:2.31,1:0)
. . S LA7RINFO(LA7X)=$P(LA7I(2),"^",LA7J+1) ; Value
. . S $P(LA7RINFO(LA7X),"^",2)=$S(LA7J=4:$P(LA7I(2),"^",7),1:$P(LA7I(2),"^",LA7J+2)) ; Units
. . S LA7RINFO(LA7X,LA7I)=LA7RINFO(LA7X)_"^"_$P(LA7I(0),"^",2)
;
I 'LA7TCNT,'LA7QUIT S LA7QUIT="1^Accession is not on this shipping manifest"
I '$O(LA7RINFO(0)),'LA7QUIT S LA7QUIT="1^No test needs required information for shipping"
I LA7QUIT Q
;
S LA7CDT=+$P($G(^LRO(68,LA7AA,1,LA7AD,1,LA7AN,3)),"^")
S LA7Y=0
F S LA7Y=$O(LA7RINFO(LA7Y)) Q:'LA7Y D Q:LA7QUIT
. N DA,DIR,DIRUT
. S DIR(0)="62.801,"_LA7Y
. S DIR("A")=$$GET1^DID(62.801,LA7Y,"","LABEL")
. I LA7Y=2.21 D
. . S DIR("A",1)=" "
. . S DIR("A",2)="Specimen Collection Date/time: "_$$FMTE^XLFDT(LA7CDT,"M")
. . S $P(DIR(0),"^",3)="I Y<LA7CDT!(Y>$$NOW^XLFDT) K X" ; d/t after specimen collect d/t
. I LA7Y'=2.21 D
. . N LA7X
. . S LA7X=$$GET1^DIQ(64.061,$P(LA7RINFO(LA7Y),"^",2)_",",.01) ; Units
. . S DIR("A")=DIR("A")_" (in "_LA7X_")"
. I $P(LA7RINFO(LA7Y),"^")'="" D ; Default value
. . I LA7Y=2.21 S DIR("B")=$$FMTE^XLFDT($P(LA7RINFO(LA7Y),"^"))
. . E S DIR("B")=$P(LA7RINFO(LA7Y),"^")
. D ^DIR
. I $D(DTOUT)!$D(DUOUT) S LA7QUIT=1 Q
. S $P(LA7INFO(LA7Y),"^")=$P(Y,"^") ; New value
I LA7QUIT Q
;
S LA7Y=0
F S LA7Y=$O(LA7RINFO(LA7Y)) Q:'LA7Y D
. S LA7I=0
. F S LA7I=$O(LA7RINFO(LA7Y,LA7I)) Q:'LA7I D
. . I $P(LA7INFO(LA7Y),"^")=$P(LA7RINFO(LA7Y,LA7I),"^") Q ; Value unchanged
. . N FDA,LA7628,LA768,LA7DATA
. . S LA762801=LA7I_","_+LA7SM_","
. . I LA7Y=2.21 D
. . . N LA7DURT,LA7UID,LA7UNITS,LA7X
. . . S LA7UNITS=$$GET1^DIQ(64.061,+$P(LA7RINFO(LA7Y,LA7I),"^",2)_",",.01,"E")
. . . S LA7DURT=$$FMDIFF^XLFDT(LA7INFO(LA7Y),LA7CDT,2) ; Collection duration (in seconds)
. . . I LA7UNITS="min" S LA7DURT=$FN(LA7DURT/60,"",0) ; Convert to minutes, rounded to nearest minute.
. . . I LA7UNITS="hr" S LA7DURT=$FN(LA7DURT/3600,"",0) ; Convert to hours, rounded to nearest hour.
. . . S FDA(62.8,62.801,LA762801,2.22)=LA7DURT
. . S FDA(62.8,62.801,LA762801,LA7Y)=$P(LA7INFO(LA7Y),"^") ; New value
. . D FILE^DIE("","FDA(62.8)","LA7DIE(2)") ; Update required info
. . ; Update event file
. . S LA7DATA="SM40^"_$$NOW^XLFDT_"^"_$P(LA7RINFO(LA7Y,LA7I),"^",3)_"^"_$P(LA7SM,"^",2)
. . D SEUP^LA7SMU(LA7UID,2,LA7DATA)
Q
--- Routine Detail --- with STRUCTURED ROUTINE LISTING ---[H[J[2J[HLA7SM2A 3525 printed Dec 13, 2024@01:39:27 Page 2
LA7SM2A ;DALOI/JMC - Shipping Manifest Options ;Oct 4, 2006
+1 ;;5.2;AUTOMATED LAB INSTRUMENTS;**74**;Sep 27, 1994;Build 229
+2 ;
+3 ; Continuation of LA7SM2
+4 ;
INFOEE ; Required Info Enter/Edit
+1 ;
+2 ; Called by LA7SM2
+3 ;
+4 NEW DIR,DIROUT,DIRUT,DTOUT,DUOUT,LA7CDT,LA7I,LA7INFO,LA7J,LA7RINFO,LA7TCNT,LA7X,LA7Y,X,Y
+5 ;
+6 DO SEL^LA7SM
+7 IF LA7QUIT
QUIT
+8 ;
+9 SET (LA7I,LA7TCNT)=0
+10 FOR
SET LA7I=$ORDER(^LAHM(62.8,+LA7SM,10,"UID",LA7UID,LA7I))
if 'LA7I
QUIT
Begin DoDot:1
+11 FOR LA7J=0,1,2
SET LA7I(LA7J)=$GET(^LAHM(62.8,+LA7SM,10,LA7I,LA7J))
+12 ; Previously "removed".
IF $PIECE(LA7I(0),"^",8)=0
QUIT
+13 ; Not pending shipment
IF $PIECE(LA7I(0),"^",8)
IF $PIECE(LA7I(0),"^",8)'=1
SET LA7QUIT="1^Accession not pending shipment"
QUIT
+14 SET LA7TCNT=LA7TCNT+1
+15 FOR LA7J=1,4
IF $PIECE(LA7I(1),"^",LA7J)
Begin DoDot:2
+16 ; No units specified
IF '$PIECE(LA7I(1),"^",LA7J+2)
QUIT
+17 SET LA7X=$SELECT(LA7J=1:1.11,LA7J=4:1.21,1:0)
+18 ; Value
SET LA7RINFO(LA7X)=$PIECE(LA7I(1),"^",LA7J+1)
+19 ; Units
SET $PIECE(LA7RINFO(LA7X),"^",2)=$PIECE(LA7I(1),"^",LA7J+2)
+20 SET LA7RINFO(LA7X,LA7I)=LA7RINFO(LA7X)_"^"_$PIECE(LA7I(0),"^",2)
End DoDot:2
+21 FOR LA7J=1,4,8
IF $PIECE(LA7I(2),"^",LA7J)
Begin DoDot:2
+22 ; No units specified.
IF '($SELECT(LA7J=4:$PIECE(LA7I(2),"^",7),1:$PIECE(LA7I(2),"^",LA7J+2)))
QUIT
+23 SET LA7X=$SELECT(LA7J=1:2.11,LA7J=4:2.21,LA7J=8:2.31,1:0)
+24 ; Value
SET LA7RINFO(LA7X)=$PIECE(LA7I(2),"^",LA7J+1)
+25 ; Units
SET $PIECE(LA7RINFO(LA7X),"^",2)=$SELECT(LA7J=4:$PIECE(LA7I(2),"^",7),1:$PIECE(LA7I(2),"^",LA7J+2))
+26 SET LA7RINFO(LA7X,LA7I)=LA7RINFO(LA7X)_"^"_$PIECE(LA7I(0),"^",2)
End DoDot:2
End DoDot:1
+27 ;
+28 IF 'LA7TCNT
IF 'LA7QUIT
SET LA7QUIT="1^Accession is not on this shipping manifest"
+29 IF '$ORDER(LA7RINFO(0))
IF 'LA7QUIT
SET LA7QUIT="1^No test needs required information for shipping"
+30 IF LA7QUIT
QUIT
+31 ;
+32 SET LA7CDT=+$PIECE($GET(^LRO(68,LA7AA,1,LA7AD,1,LA7AN,3)),"^")
+33 SET LA7Y=0
+34 FOR
SET LA7Y=$ORDER(LA7RINFO(LA7Y))
if 'LA7Y
QUIT
Begin DoDot:1
+35 NEW DA,DIR,DIRUT
+36 SET DIR(0)="62.801,"_LA7Y
+37 SET DIR("A")=$$GET1^DID(62.801,LA7Y,"","LABEL")
+38 IF LA7Y=2.21
Begin DoDot:2
+39 SET DIR("A",1)=" "
+40 SET DIR("A",2)="Specimen Collection Date/time: "_$$FMTE^XLFDT(LA7CDT,"M")
+41 ; d/t after specimen collect d/t
SET $PIECE(DIR(0),"^",3)="I Y<LA7CDT!(Y>$$NOW^XLFDT) K X"
End DoDot:2
+42 IF LA7Y'=2.21
Begin DoDot:2
+43 NEW LA7X
+44 ; Units
SET LA7X=$$GET1^DIQ(64.061,$PIECE(LA7RINFO(LA7Y),"^",2)_",",.01)
+45 SET DIR("A")=DIR("A")_" (in "_LA7X_")"
End DoDot:2
+46 ; Default value
IF $PIECE(LA7RINFO(LA7Y),"^")'=""
Begin DoDot:2
+47 IF LA7Y=2.21
SET DIR("B")=$$FMTE^XLFDT($PIECE(LA7RINFO(LA7Y),"^"))
+48 IF '$TEST
SET DIR("B")=$PIECE(LA7RINFO(LA7Y),"^")
End DoDot:2
+49 DO ^DIR
+50 IF $DATA(DTOUT)!$DATA(DUOUT)
SET LA7QUIT=1
QUIT
+51 ; New value
SET $PIECE(LA7INFO(LA7Y),"^")=$PIECE(Y,"^")
End DoDot:1
if LA7QUIT
QUIT
+52 IF LA7QUIT
QUIT
+53 ;
+54 SET LA7Y=0
+55 FOR
SET LA7Y=$ORDER(LA7RINFO(LA7Y))
if 'LA7Y
QUIT
Begin DoDot:1
+56 SET LA7I=0
+57 FOR
SET LA7I=$ORDER(LA7RINFO(LA7Y,LA7I))
if 'LA7I
QUIT
Begin DoDot:2
+58 ; Value unchanged
IF $PIECE(LA7INFO(LA7Y),"^")=$PIECE(LA7RINFO(LA7Y,LA7I),"^")
QUIT
+59 NEW FDA,LA7628,LA768,LA7DATA
+60 SET LA762801=LA7I_","_+LA7SM_","
+61 IF LA7Y=2.21
Begin DoDot:3
+62 NEW LA7DURT,LA7UID,LA7UNITS,LA7X
+63 SET LA7UNITS=$$GET1^DIQ(64.061,+$PIECE(LA7RINFO(LA7Y,LA7I),"^",2)_",",.01,"E")
+64 ; Collection duration (in seconds)
SET LA7DURT=$$FMDIFF^XLFDT(LA7INFO(LA7Y),LA7CDT,2)
+65 ; Convert to minutes, rounded to nearest minute.
IF LA7UNITS="min"
SET LA7DURT=$FNUMBER(LA7DURT/60,"",0)
+66 ; Convert to hours, rounded to nearest hour.
IF LA7UNITS="hr"
SET LA7DURT=$FNUMBER(LA7DURT/3600,"",0)
+67 SET FDA(62.8,62.801,LA762801,2.22)=LA7DURT
End DoDot:3
+68 ; New value
SET FDA(62.8,62.801,LA762801,LA7Y)=$PIECE(LA7INFO(LA7Y),"^")
+69 ; Update required info
DO FILE^DIE("","FDA(62.8)","LA7DIE(2)")
+70 ; Update event file
+71 SET LA7DATA="SM40^"_$$NOW^XLFDT_"^"_$P(LA7RINFO(LA7Y,LA7I),"^",3)_"^"_$PIECE(LA7SM,"^",2)
+72 DO SEUP^LA7SMU(LA7UID,2,LA7DATA)
End DoDot:2
End DoDot:1
+73 QUIT