LR7OU64 ;SLC/DCM/FHS/DALISC - RESULT CODE NLT LINKING UTILITY AUTO ; 6/12/12 2:00
;;5.2;LAB SERVICE;**153,201,350**;Sep 27, 1994;Build 230
EN ;
;Find matches between file 64 and 60
D MSG
LIST ;
K DIR S DIR("A")="Would you like a list of RESULT NLT CODES from LABORATORY TEST file",DIR(0)="Y",DIR("B")="No"
D ^DIR G:$D(DIRUT)!($D(DTOUT))!($D(DUOUT)) END I Y=1 D G:$D(DIRUT)!($D(DTOUT))!($D(DUOUT))!(Y=0) END G LK
. D LST K DIR S DIR("A")="Ready to start linkage procedure ",DIR(0)="Y"
. D ^DIR
W ! K DIR S DIR("A")="Ready to proceed",DIR(0)="Y"
D ^DIR G:$D(DTOUT)!($D(DUOUT))!($D(DIROUT))!(Y'=1) END
LK W !!,$$CJ^XLFSTR("Do you want to automatically link entries when there is an exact match",80)
W !,$$CJ^XLFSTR("on the NAME in both files",80) S %=2 D YN^DICN G:%=-1 END
I %=0 W !!,$$CJ^XLFSTR("Answer YES to automatically link the entries, or NO to be prompted for each",80) G LK
S AUTO=$S(%=1:1,1:0)
LAB ;
W:$G(AUTO) !?5,"Press Return to Stop Auto Update",!
S (END,LRN)="" F S LRN=$O(^LAB(60,"B",LRN)) Q:LRN=""!($G(END)) D
. S LRIEN="" F S LRIEN=+$O(^LAB(60,"B",LRN,LRIEN)) Q:LRIEN<1!($G(END)) I '$G(^(LRIEN)) D CHECK
W:'$G(END) !!,$$CJ^XLFSTR("End of loop",80),!
G END
Q
CHECK ;
S LRMIEN=0
Q:'$D(^LAB(60,LRIEN,0))#2!('$P(^(0),";",2))!($P($G(^LAB(60,LRIEN,64)),U,2))!($G(END))
S LRDATA=$P(^LAB(60,LRIEN,0),U),LRTY=$P(^(0),U,3) Q:LRTY=""!(LRTY="N")
S LRNU=$$UP^XLFSTR(LRN),X=+$O(^LAM("D",LRNU,0)) I $D(^LAM(X,0)),^(0)'["~" S LRMIEN=X
D:'LRMIEN 64 Q:'LRMIEN!($G(END))
Q:'$D(^LAM(LRMIEN,0))#2 S LRCODE=$P(^(0),U,2) Q:'LRCODE!($D(^LAB(60,"AE",LRCODE)))
Q:'$D(^LAM(LRMIEN,0)) S LRMNAME=$P(^(0),U)
W !!,"60 = ",LRDATA,!,"64 = ",LRMNAME_" "_LRCODE
D LINK(LRIEN,LRMIEN,AUTO)
Q
64 ;Look for NATIONAL VA LAB CODE
S LRMIEN=0,I=+$P($G(^LAB(60,LRIEN,64)),U,2) I $D(^LAM(I,0)),^(0)'["~" S LRMIEN=I
Q:'LRMIEN
W !,$C(7),?5,"Did not find a exact name match for Lab Test "_LRDATA,!
K DIR
W !," Want to use the ["_$P(^LAM(LRMIEN,0),U)_"] NATIONAL VA LAB CODE instead?"
K DIR S DIR(0)="Y" D ^DIR S:Y'=1 LRMIEN=0 Q
Q
LINK(X60,X641,DOIT) ;Link the 2 files
S LRDATA="`"_X60 I DOIT S %=1 G L2
L1 W !?5,"Link the two entries" S %=2 D YN^DICN Q:%=2 I %=-1 S END=1 Q
I $G(DTOUT) S END=1 Q
I %=0 W !,"Enter Yes to link the entries, No to leave it alone." G L1
L2 K DIE,DA,DR,DIC S DIE="^LAB(60,",DA=X60,DR="64.1///`"_X641,DLAYGO=60 D ^DIE K DLAYGO
I $P($G(^LAB(60,X60,64)),U,2) W !?32,"o----LINKED----o",! D Q
. R X:1 I $T W !?20,"User terminated update",!,$C(7) S END=1
W !!?15,"***************** NOT LINKED ***************",!
W !!?5,"Press Return to continue" R X:DTIME S:$G(DTOUT)!($E(X)=U) END=1
Q
END ;
Q:$G(LRDBUG)
K %,AUTO,DA,DIC,DIE,DIR,DOIT,DR,END,LRDATA,LRIEN,LRMIEN,LRN,LRNU
K LRSUF,LRTY,X,X60,X64,Y,LRMNAME,D1,D0,DLAYGO,I,LRCODE,END
K FLG,XXX,ZZ,ZZ1,X,Y,Y64,DLAYGO,DX,S
Q
LST ;
K ^TMP("LR",$J),DIC I $O(^LAB(60,"AE",0))="" W !,"Nothing in X-Ref to Print.",!! Q
W !!,$$CJ^XLFSTR("I will produce a list of ",80)
W !,$$CJ^XLFSTR("NATIONAL VA Code / Result NLT codes from LABORATORY TEST file",80),!
K %ZIS S %ZIS="QN",%ZIS("A")="Printer Name " D ^%ZIS G:POP CLEAN
I IO'=IO(0)!($D(IO("Q"))) S ZTRTN="DQ^LR7OU64",ZTIO=ION,ZTDESC="PRINT NLT CODES FROM ^LAB(60 " W !!?10,"Report Queued to "_ION,! D ^%ZTLOAD,^%ZISC G CLEAN
DQ K ^TMP("LR",$J),DX S:$D(ZTQUEUED) ZTREQ="@"
W !!,$$CJ^XLFSTR("List of NATIONAL VA Code / Result NLT codes from LABORATORY TEST file",80),!!
W ?6,$$NOW^XLFDT,!
S LRNLT="" F S LRNLT=$O(^LAB(60,"AE",LRNLT)) Q:LRNLT="" D
. S LRLAB=0 F S LRLAB=$O(^LAB(60,"AE",LRNLT,LRLAB)) Q:LRLAB<1 D
. . S ^TMP("LR",$J,$P(^LAB(60,LRLAB,0),U),LRNLT)=LRLAB
S DIC="^LAB(60,"
S NODE="^TMP(""LR"","_$J_")" F S NODE=$Q(@NODE) Q:$QS(NODE,2)'=$J D
. S DA=@NODE,DR=64 W !,"Test Name: ",$P(^LAB(60,DA,0),U)
. D EN^LRDIQ S:$E(IOST,1,2)="P-" S=0
CLEAN K DIC,DA,NODE,LRNLT,LRLAB,DR,DX,S,^TMP("LR",$J)
Q
MSG W !,$$CJ^XLFSTR("This option will Auto Link NLT RESULT CODE to Laboratory test file (#60).",80)
W !,$$CJ^XLFSTR("NLT RESULT CODE is used by the LEDI software to identify",80)
W !,$$CJ^XLFSTR("test results returned by Host Laboratories.",80)
W !,$$CJ^XLFSTR("ONLY GENERIC NLT CODES CAN BE LINKED TO LAB TEST ",80),!!
W !,$$CJ^XLFSTR("Only ATOMIC lab tests can have an NLT RESULT CODE.",80),! ;[ccr-8218]
Q
--- Routine Detail --- with STRUCTURED ROUTINE LISTING ---[H[J[2J[HLR7OU64 4356 printed Oct 16, 2024@18:06:38 Page 2
LR7OU64 ;SLC/DCM/FHS/DALISC - RESULT CODE NLT LINKING UTILITY AUTO ; 6/12/12 2:00
+1 ;;5.2;LAB SERVICE;**153,201,350**;Sep 27, 1994;Build 230
EN ;
+1 ;Find matches between file 64 and 60
+2 DO MSG
LIST ;
+1 KILL DIR
SET DIR("A")="Would you like a list of RESULT NLT CODES from LABORATORY TEST file"
SET DIR(0)="Y"
SET DIR("B")="No"
+2 DO ^DIR
if $DATA(DIRUT)!($DATA(DTOUT))!($DATA(DUOUT))
GOTO END
IF Y=1
Begin DoDot:1
+3 DO LST
KILL DIR
SET DIR("A")="Ready to start linkage procedure "
SET DIR(0)="Y"
+4 DO ^DIR
End DoDot:1
if $DATA(DIRUT)!($DATA(DTOUT))!($DATA(DUOUT))!(Y=0)
GOTO END
GOTO LK
+5 WRITE !
KILL DIR
SET DIR("A")="Ready to proceed"
SET DIR(0)="Y"
+6 DO ^DIR
if $DATA(DTOUT)!($DATA(DUOUT))!($DATA(DIROUT))!(Y'=1)
GOTO END
LK WRITE !!,$$CJ^XLFSTR("Do you want to automatically link entries when there is an exact match",80)
+1 WRITE !,$$CJ^XLFSTR("on the NAME in both files",80)
SET %=2
DO YN^DICN
if %=-1
GOTO END
+2 IF %=0
WRITE !!,$$CJ^XLFSTR("Answer YES to automatically link the entries, or NO to be prompted for each",80)
GOTO LK
+3 SET AUTO=$SELECT(%=1:1,1:0)
LAB ;
+1 if $GET(AUTO)
WRITE !?5,"Press Return to Stop Auto Update",!
+2 SET (END,LRN)=""
FOR
SET LRN=$ORDER(^LAB(60,"B",LRN))
if LRN=""!($GET(END))
QUIT
Begin DoDot:1
+3 SET LRIEN=""
FOR
SET LRIEN=+$ORDER(^LAB(60,"B",LRN,LRIEN))
if LRIEN<1!($GET(END))
QUIT
IF '$GET(^(LRIEN))
DO CHECK
End DoDot:1
+4 if '$GET(END)
WRITE !!,$$CJ^XLFSTR("End of loop",80),!
+5 GOTO END
+6 QUIT
CHECK ;
+1 SET LRMIEN=0
+2 if '$DATA(^LAB(60,LRIEN,0))#2!('$PIECE(^(0),";",2))!($PIECE($GET(^LAB(60,LRIEN,64)),U,2))!($GET(END))
QUIT
+3 SET LRDATA=$PIECE(^LAB(60,LRIEN,0),U)
SET LRTY=$PIECE(^(0),U,3)
if LRTY=""!(LRTY="N")
QUIT
+4 SET LRNU=$$UP^XLFSTR(LRN)
SET X=+$ORDER(^LAM("D",LRNU,0))
IF $DATA(^LAM(X,0))
IF ^(0)'["~"
SET LRMIEN=X
+5 if 'LRMIEN
DO 64
if 'LRMIEN!($GET(END))
QUIT
+6 if '$DATA(^LAM(LRMIEN,0))#2
QUIT
SET LRCODE=$PIECE(^(0),U,2)
if 'LRCODE!($DATA(^LAB(60,"AE",LRCODE)))
QUIT
+7 if '$DATA(^LAM(LRMIEN,0))
QUIT
SET LRMNAME=$PIECE(^(0),U)
+8 WRITE !!,"60 = ",LRDATA,!,"64 = ",LRMNAME_" "_LRCODE
+9 DO LINK(LRIEN,LRMIEN,AUTO)
+10 QUIT
64 ;Look for NATIONAL VA LAB CODE
+1 SET LRMIEN=0
SET I=+$PIECE($GET(^LAB(60,LRIEN,64)),U,2)
IF $DATA(^LAM(I,0))
IF ^(0)'["~"
SET LRMIEN=I
+2 if 'LRMIEN
QUIT
+3 WRITE !,$CHAR(7),?5,"Did not find a exact name match for Lab Test "_LRDATA,!
+4 KILL DIR
+5 WRITE !," Want to use the ["_$PIECE(^LAM(LRMIEN,0),U)_"] NATIONAL VA LAB CODE instead?"
+6 KILL DIR
SET DIR(0)="Y"
DO ^DIR
if Y'=1
SET LRMIEN=0
QUIT
+7 QUIT
LINK(X60,X641,DOIT) ;Link the 2 files
+1 SET LRDATA="`"_X60
IF DOIT
SET %=1
GOTO L2
L1 WRITE !?5,"Link the two entries"
SET %=2
DO YN^DICN
if %=2
QUIT
IF %=-1
SET END=1
QUIT
+1 IF $GET(DTOUT)
SET END=1
QUIT
+2 IF %=0
WRITE !,"Enter Yes to link the entries, No to leave it alone."
GOTO L1
L2 KILL DIE,DA,DR,DIC
SET DIE="^LAB(60,"
SET DA=X60
SET DR="64.1///`"_X641
SET DLAYGO=60
DO ^DIE
KILL DLAYGO
+1 IF $PIECE($GET(^LAB(60,X60,64)),U,2)
WRITE !?32,"o----LINKED----o",!
Begin DoDot:1
+2 READ X:1
IF $TEST
WRITE !?20,"User terminated update",!,$CHAR(7)
SET END=1
End DoDot:1
QUIT
+3 WRITE !!?15,"***************** NOT LINKED ***************",!
+4 WRITE !!?5,"Press Return to continue"
READ X:DTIME
if $GET(DTOUT)!($EXTRACT(X)=U)
SET END=1
+5 QUIT
END ;
+1 if $GET(LRDBUG)
QUIT
+2 KILL %,AUTO,DA,DIC,DIE,DIR,DOIT,DR,END,LRDATA,LRIEN,LRMIEN,LRN,LRNU
+3 KILL LRSUF,LRTY,X,X60,X64,Y,LRMNAME,D1,D0,DLAYGO,I,LRCODE,END
+4 KILL FLG,XXX,ZZ,ZZ1,X,Y,Y64,DLAYGO,DX,S
+5 QUIT
LST ;
+1 KILL ^TMP("LR",$JOB),DIC
IF $ORDER(^LAB(60,"AE",0))=""
WRITE !,"Nothing in X-Ref to Print.",!!
QUIT
+2 WRITE !!,$$CJ^XLFSTR("I will produce a list of ",80)
+3 WRITE !,$$CJ^XLFSTR("NATIONAL VA Code / Result NLT codes from LABORATORY TEST file",80),!
+4 KILL %ZIS
SET %ZIS="QN"
SET %ZIS("A")="Printer Name "
DO ^%ZIS
if POP
GOTO CLEAN
+5 IF IO'=IO(0)!($DATA(IO("Q")))
SET ZTRTN="DQ^LR7OU64"
SET ZTIO=ION
SET ZTDESC="PRINT NLT CODES FROM ^LAB(60 "
WRITE !!?10,"Report Queued to "_ION,!
DO ^%ZTLOAD
DO ^%ZISC
GOTO CLEAN
DQ KILL ^TMP("LR",$JOB),DX
if $DATA(ZTQUEUED)
SET ZTREQ="@"
+1 WRITE !!,$$CJ^XLFSTR("List of NATIONAL VA Code / Result NLT codes from LABORATORY TEST file",80),!!
+2 WRITE ?6,$$NOW^XLFDT,!
+3 SET LRNLT=""
FOR
SET LRNLT=$ORDER(^LAB(60,"AE",LRNLT))
if LRNLT=""
QUIT
Begin DoDot:1
+4 SET LRLAB=0
FOR
SET LRLAB=$ORDER(^LAB(60,"AE",LRNLT,LRLAB))
if LRLAB<1
QUIT
Begin DoDot:2
+5 SET ^TMP("LR",$JOB,$PIECE(^LAB(60,LRLAB,0),U),LRNLT)=LRLAB
End DoDot:2
End DoDot:1
+6 SET DIC="^LAB(60,"
+7 SET NODE="^TMP(""LR"","_$JOB_")"
FOR
SET NODE=$QUERY(@NODE)
if $QSUBSCRIPT(NODE,2)'=$JOB
QUIT
Begin DoDot:1
+8 SET DA=@NODE
SET DR=64
WRITE !,"Test Name: ",$PIECE(^LAB(60,DA,0),U)
+9 DO EN^LRDIQ
if $EXTRACT(IOST,1,2)="P-"
SET S=0
End DoDot:1
CLEAN KILL DIC,DA,NODE,LRNLT,LRLAB,DR,DX,S,^TMP("LR",$JOB)
+1 QUIT
MSG WRITE !,$$CJ^XLFSTR("This option will Auto Link NLT RESULT CODE to Laboratory test file (#60).",80)
+1 WRITE !,$$CJ^XLFSTR("NLT RESULT CODE is used by the LEDI software to identify",80)
+2 WRITE !,$$CJ^XLFSTR("test results returned by Host Laboratories.",80)
+3 WRITE !,$$CJ^XLFSTR("ONLY GENERIC NLT CODES CAN BE LINKED TO LAB TEST ",80),!!
+4 ;[ccr-8218]
WRITE !,$$CJ^XLFSTR("Only ATOMIC lab tests can have an NLT RESULT CODE.",80),!
+5 QUIT