MPIFA31B ;BP/CMC-BUILD A31 MSGS ;7/15/21 15:04
;;1.0;MASTER PATIENT INDEX VISTA;**22,24,27,28,31,25,44,46,54,59,60,64,68,75,78**;30 Apr 99;Build 1
;
; Integration Agreements Utilized:
; START, EXC, STOP^RGHLLOG - #2796
; BLDEVN, BLDPD1, BLDPID^VAFCQRY - #3630
; $$PV1^VAFCSB, $$RADE^VAFCSB, $$LABE^VAFCSB, $$PHARA^VAFCSB, $$PV2^VAFCSB - #4921
;
TA31 ; Tasked entry point
N TMP
S TMP=$$A31(DFN)
Q
;
A31(DFN) ;BUILD AND SEND A31
I $P($$SITE^VASITE,"^",3)=200 Q 1
; ^ PATCH 25 IF this is the FHIE Host system, don't build A31 messages
N RESLT,CNT,MPI,EVN,TCNT,ERR,PD1,PID,EN,LAB,PV1,PV2,RAD,PRE,OLD,ZPD
N ZEL,ZSP,SIDG,NAMECOMP,DODF,DODD,DODNP,DODOPT,DODDISDT,SECLVL,SEXOR,SEXORD,PRON,PROND
K HLA("HLA"),HLA("HLS")
Q:$E($$GETICN^MPIF001(DFN),1,3)=$P($$SITE^VASITE(),"^",3) 0
; ^ LOCAL ICN DON'T SEND
Q:+$$GETICN^MPIF001(DFN)=-1 0
; ^ NO ICN DON'T SEND
S CNT=1
D INIT^HLFNC2("MPIF ADT-A31 SERVER",.HL)
I $O(HL(""))="" Q "-1^"_$P(HL,"^",2)
S HLECH=HL("ECH"),HLFS=HL("FS"),COMP=$E(HL("ECH"),1),REP=$E(HL("ECH"),2),SUBCOMP=$E(HL("ECH"),4)
S ERR="",TCNT=0
D BLDEVN^VAFCQRY(DFN,"1,2",.EVN,.HL,"A31",.ERR)
Q:ERR'="" ERR
D BLDPID^VAFCQRY(DFN,1,"ALL",.PID,.HL,.ERR) ;**25
Q:ERR'="" ERR
D BLDPD1^VAFCQRY(DFN,"3",.PD1,.HL,.ERR) ;**44 NEW PD1 SEGMENT VALUES -- SENDING CMOR AGAIN AS WITHOUT 40 ON THE MPI SIDE THIS IS A PROBLEM.
;S PD1=$$PD1^VAFCSB ;**44 NEW PD1 SEGMENT VALUES -- IMDQ DECIDED NOT TO SEND PREFERRED FACILITY 9/7/06
N X S X="VAFCSB" X ^%ZOSF("TEST") I $T D
.;**44 VAFCSB coming in with DG*5.3*707
.S PV1=$$PV1^VAFCSB ;**44 PV1 segment
.S RAD=$$RADE^VAFCSB ;**44 OBX FOR LAST RADIOLOGY EXAM
.S LAB=$$LABE^VAFCSB ;**44 OBX FOR LAST LAB EXAM
.S PRE=$$PHARA^VAFCSB ;**44 OBX FOR ACTIVE PRESCRIPTIONS
.S SIDG=$$SIG^VAFCSB(DFN) ;**59 OBX FOR SELF ID GENDER
.S NAMECOMP=$$NAMEOBX^VAFCSB(DFN) ;**59,MVI_3975 (mko): OBX for Patient .01 and Name Components
.S SECLVL=$$SECLOG^VAFCSB(DFN) ;**68 Story 783361 (ckn) - OBX for Security Level
.D SEXOR^VAFCSB(DFN,.SEXOR) ;**78, VAMPI-11114 (dri)
.D SEXORD^VAFCSB(DFN,.SEXORD) ;**78, VAMPI-11114 (dri)
.D PRON^VAFCSB(DFN,.PRON) ;**78, VAMPI-11118 (dri)
.D PROND^VAFCSB(DFN,.PROND) ;**78, VAMPI-11118 (dri)
.S PV2=$$PV2^VAFCSB ;**44 PV2 segment
S DODF=$$DODF^VAFCSB(DFN) ;**60 OBX for DOD fields
;**64 Story 323009 (ckn) : OBX for Additional DOD fields
S DODD=$$DODD^VAFCSB(DFN) ;Date Of Death Documents
S DODOPT=$$DODOPT^VAFCSB(DFN) ; Date Of Death Option used
S DODNP=$$DODNTPRV^VAFCSB(DFN) ; Date Of Death Notification provider
S OLD=$$OLD ;**54,MVI_913: OBX to mark an older record
S ZPD=$$EN1^VAFHLZPD(DFN,"1,17,21,34") ;25 ;**44 ADDED PSEUDO SSN REASON (34), 1 and 21 TO ZPD SEGMENT
S ZSP=$$EN^VAFHLZSP(DFN) ;**59
S ZEL=$$EN^VAFHLZEL(DFN,"1,8,9",1) ;**59
S EN=1
S HLA("HLS",EN)=EVN(1),EN=EN+1
S CNT=0 F S CNT=$O(PID(CNT)) Q:CNT="" D
.I CNT=1 S HLA("HLS",EN)=PID(CNT)
.I CNT>1 S HLA("HLS",EN,CNT-1)=PID(CNT)
S EN=EN+1
I $G(PD1(1))'="" S HLA("HLS",EN)=PD1(1),EN=EN+1 ;**44 only pass PD1 segment if has values -- SENDING CMOR AGAIN AS WITHOUT 40 ON MPI SIDE THIS IS A PROBLEM.
I $G(PV1)'="" S HLA("HLS",EN)=PV1,EN=EN+1 ;**44 only pass PV1 segment if has values
I $G(PV2)'="" S HLA("HLS",EN)=PV2,EN=EN+1 ;**44 only pass PV2 segment if has values
I $G(RAD)'="" S HLA("HLS",EN)=RAD,EN=EN+1 ;**44 only pass RADIOLOGY IN OBX segment if has values
I $G(LAB)'="" S HLA("HLS",EN)=LAB,EN=EN+1 ;**44 only pass LAB IN OBX segment if has values
I $G(PRE)'="" S HLA("HLS",EN)=PRE,EN=EN+1 ;**44 only pass PRESCRIPTION IN OBX segment if has values
I $G(OLD)'="" S HLA("HLS",EN)=OLD,EN=EN+1 ;**54,MVI_913: pass OLDER RECORD in OBX if flagged as such
I $G(SIDG)'="" S HLA("HLS",EN)=SIDG,EN=EN+1 ;**59
I $G(DODF)'="" S HLA("HLS",EN)=DODF,EN=EN+1 ;**60 MVI_4733 (ckn) Pass DOD fields in OBX
;**64 Story 323009 (ckn) : Pass additional DOD fields in OBX
I $G(DODD)'="" S HLA("HLS",EN)=DODD,EN=EN+1
I $G(DODOPT)'="" S HLA("HLS",EN)=DODOPT,EN=EN+1
I $G(DODNP)'="" S HLA("HLS",EN)=DODNP,EN=EN+1
I $G(NAMECOMP)'="" S HLA("HLS",EN)=NAMECOMP,EN=EN+1 ;**59,MVI_3975 (mko): pass NAME COMPONENTS in OBX
I $G(SECLVL)'="" S HLA("HLS",EN)=SECLVL,EN=EN+1 ;**68,Story 783361 (ckn)- Security
I $O(SEXOR(0)) N CNT S CNT=0 F S CNT=$O(SEXOR(CNT)) Q:'CNT S HLA("HLS",EN)=SEXOR(CNT),EN=EN+1 ;**78, VAMPI-11114 (dri)
I $O(SEXORD(0)) D S EN=EN+1 ;**78, VAMPI-11114 (dri)
.N CNT,LVL
.S LVL=1,CNT=0 F S CNT=$O(SEXORD(CNT)) Q:'CNT D
..I CNT=1 S HLA("HLS",EN)=SEXORD(CNT)
..I CNT>1 S HLA("HLS",EN,LVL)=SEXORD(CNT),LVL=LVL+1
I $O(PRON(0)) N CNT S CNT=0 F S CNT=$O(PRON(CNT)) Q:'CNT S HLA("HLS",EN)=PRON(CNT),EN=EN+1 ;**78, VAMPI-11118 (dri)
I $O(PROND(0)) D S EN=EN+1 ;**78, VAMPI-11118 (dri)
.N CNT,LVL
.S LVL=1,CNT=0 F S CNT=$O(PROND(CNT)) Q:'CNT D
..I CNT=1 S HLA("HLS",EN)=PROND(CNT)
..I CNT>1 S HLA("HLS",EN,LVL)=PROND(CNT),LVL=LVL+1
S HLA("HLS",EN)=ZPD,EN=EN+1 ;**44 ZPD SEGMENT
I $G(ZSP)'="" S HLA("HLS",EN)=ZSP,EN=EN+1 ;**59 ZSP segment
I $G(ZEL)'="" S HLA("HLS",EN)=ZEL,EN=EN+1 ;**59 ZEL segment
S MPI=$$MPILINK^MPIFAPI()
Q:$P($G(MPI),"^")=-1 "-1^No logical link defined for the MPI"
;**75 - Story - 1260465 (ckn) - Include 200M in HLL links for HAC
S HLL("LINKS",1)="MPIF ADT-A31 CLIENT^"_MPI_$S($P($$SITE^VASITE(),"^",3)=741:"^200M",1:"")
D GENERATE^HLMA("MPIF ADT-A31 SERVER","LM",1,.MPIFRSLT,"","")
S RESLT=$S(+MPIFRSLT:MPIFRSLT,1:"-1^"_$P(MPIFRSLT,"^",3)) ;**68 Story 827754 (jfw) - Make Error Data Consistent (-1^msg)
S ^XTMP("MPIFA31%"_DFN,0)=$$FMADD^XLFDT(DT,5)_"^"_DT_"^"_"MPIA31 msg to MPI for DFN "_DFN
I +RESLT<0 S ^XTMP("MPIFA31%"_DFN,"MPI",0)="A" ;**68 Story 827754 (jfw) - Check for value < 0 instead of '+RESLT
K HLA,HLL("LINKS"),COMP,REP,SUBCOMP,HLA("HLA"),HLA("HLS"),MPIFRSLT
;**44 REMOVED HLEID, HLECH AND HLFS from Kill line above
Q RESLT
;
RES ;
N NXT,DFN,ERROR,CODE S CODE=""
F NXT=1:1 X HLNEXT Q:HLQUIT'>0 D
.I $E(HLNODE,1,3)="MSA" S DFN=$P($P(HLNODE,HL("FS"),7),"=",2),ERROR=$P(HLNODE,HL("FS"),4),CODE=$P(HLNODE,HL("FS"),2)
.I $E(HLNODE,1,3)="MSA"&(CODE="AR") D
..; ERROR RETURNED IN MSA - LOG EXCEPTION
..D START^RGHLLOG(HLMTIEN,"","")
..;**44 check which type of exception to be logged
..D EXC^RGHLLOG(234,ERROR,DFN) ;**46
..D STOP^RGHLLOG(0)
K:$G(DFN)>0 ^XTMP("MPIF OLD RECORDS",DFN) ;**54,MVI_913: Delete the old record designation
K ^XTMP("MPIFA31%"_DFN)
Q
;
OLD() ; Return OBX segment to flag a record as "old"
;**54,MVI_913: New subroutine
Q $S($D(^XTMP("MPIF OLD RECORDS",DFN))#2:"OBX"_HL("FS")_HL("FS")_"CE"_HL("FS")_"OLDER RECORD"_HL("FS")_HL("FS")_"Y",1:"")
;
--- Routine Detail --- with STRUCTURED ROUTINE LISTING ---[H[J[2J[HMPIFA31B 6661 printed Dec 13, 2024@02:10:48 Page 2
MPIFA31B ;BP/CMC-BUILD A31 MSGS ;7/15/21 15:04
+1 ;;1.0;MASTER PATIENT INDEX VISTA;**22,24,27,28,31,25,44,46,54,59,60,64,68,75,78**;30 Apr 99;Build 1
+2 ;
+3 ; Integration Agreements Utilized:
+4 ; START, EXC, STOP^RGHLLOG - #2796
+5 ; BLDEVN, BLDPD1, BLDPID^VAFCQRY - #3630
+6 ; $$PV1^VAFCSB, $$RADE^VAFCSB, $$LABE^VAFCSB, $$PHARA^VAFCSB, $$PV2^VAFCSB - #4921
+7 ;
TA31 ; Tasked entry point
+1 NEW TMP
+2 SET TMP=$$A31(DFN)
+3 QUIT
+4 ;
A31(DFN) ;BUILD AND SEND A31
+1 IF $PIECE($$SITE^VASITE,"^",3)=200
QUIT 1
+2 ; ^ PATCH 25 IF this is the FHIE Host system, don't build A31 messages
+3 NEW RESLT,CNT,MPI,EVN,TCNT,ERR,PD1,PID,EN,LAB,PV1,PV2,RAD,PRE,OLD,ZPD
+4 NEW ZEL,ZSP,SIDG,NAMECOMP,DODF,DODD,DODNP,DODOPT,DODDISDT,SECLVL,SEXOR,SEXORD,PRON,PROND
+5 KILL HLA("HLA"),HLA("HLS")
+6 if $EXTRACT($$GETICN^MPIF001(DFN),1,3)=$PIECE($$SITE^VASITE(),"^",3)
QUIT 0
+7 ; ^ LOCAL ICN DON'T SEND
+8 if +$$GETICN^MPIF001(DFN)=-1
QUIT 0
+9 ; ^ NO ICN DON'T SEND
+10 SET CNT=1
+11 DO INIT^HLFNC2("MPIF ADT-A31 SERVER",.HL)
+12 IF $ORDER(HL(""))=""
QUIT "-1^"_$PIECE(HL,"^",2)
+13 SET HLECH=HL("ECH")
SET HLFS=HL("FS")
SET COMP=$EXTRACT(HL("ECH"),1)
SET REP=$EXTRACT(HL("ECH"),2)
SET SUBCOMP=$EXTRACT(HL("ECH"),4)
+14 SET ERR=""
SET TCNT=0
+15 DO BLDEVN^VAFCQRY(DFN,"1,2",.EVN,.HL,"A31",.ERR)
+16 if ERR'=""
QUIT ERR
+17 ;**25
DO BLDPID^VAFCQRY(DFN,1,"ALL",.PID,.HL,.ERR)
+18 if ERR'=""
QUIT ERR
+19 ;**44 NEW PD1 SEGMENT VALUES -- SENDING CMOR AGAIN AS WITHOUT 40 ON THE MPI SIDE THIS IS A PROBLEM.
DO BLDPD1^VAFCQRY(DFN,"3",.PD1,.HL,.ERR)
+20 ;S PD1=$$PD1^VAFCSB ;**44 NEW PD1 SEGMENT VALUES -- IMDQ DECIDED NOT TO SEND PREFERRED FACILITY 9/7/06
+21 NEW X
SET X="VAFCSB"
XECUTE ^%ZOSF("TEST")
IF $TEST
Begin DoDot:1
+22 ;**44 VAFCSB coming in with DG*5.3*707
+23 ;**44 PV1 segment
SET PV1=$$PV1^VAFCSB
+24 ;**44 OBX FOR LAST RADIOLOGY EXAM
SET RAD=$$RADE^VAFCSB
+25 ;**44 OBX FOR LAST LAB EXAM
SET LAB=$$LABE^VAFCSB
+26 ;**44 OBX FOR ACTIVE PRESCRIPTIONS
SET PRE=$$PHARA^VAFCSB
+27 ;**59 OBX FOR SELF ID GENDER
SET SIDG=$$SIG^VAFCSB(DFN)
+28 ;**59,MVI_3975 (mko): OBX for Patient .01 and Name Components
SET NAMECOMP=$$NAMEOBX^VAFCSB(DFN)
+29 ;**68 Story 783361 (ckn) - OBX for Security Level
SET SECLVL=$$SECLOG^VAFCSB(DFN)
+30 ;**78, VAMPI-11114 (dri)
DO SEXOR^VAFCSB(DFN,.SEXOR)
+31 ;**78, VAMPI-11114 (dri)
DO SEXORD^VAFCSB(DFN,.SEXORD)
+32 ;**78, VAMPI-11118 (dri)
DO PRON^VAFCSB(DFN,.PRON)
+33 ;**78, VAMPI-11118 (dri)
DO PROND^VAFCSB(DFN,.PROND)
+34 ;**44 PV2 segment
SET PV2=$$PV2^VAFCSB
End DoDot:1
+35 ;**60 OBX for DOD fields
SET DODF=$$DODF^VAFCSB(DFN)
+36 ;**64 Story 323009 (ckn) : OBX for Additional DOD fields
+37 ;Date Of Death Documents
SET DODD=$$DODD^VAFCSB(DFN)
+38 ; Date Of Death Option used
SET DODOPT=$$DODOPT^VAFCSB(DFN)
+39 ; Date Of Death Notification provider
SET DODNP=$$DODNTPRV^VAFCSB(DFN)
+40 ;**54,MVI_913: OBX to mark an older record
SET OLD=$$OLD
+41 ;25 ;**44 ADDED PSEUDO SSN REASON (34), 1 and 21 TO ZPD SEGMENT
SET ZPD=$$EN1^VAFHLZPD(DFN,"1,17,21,34")
+42 ;**59
SET ZSP=$$EN^VAFHLZSP(DFN)
+43 ;**59
SET ZEL=$$EN^VAFHLZEL(DFN,"1,8,9",1)
+44 SET EN=1
+45 SET HLA("HLS",EN)=EVN(1)
SET EN=EN+1
+46 SET CNT=0
FOR
SET CNT=$ORDER(PID(CNT))
if CNT=""
QUIT
Begin DoDot:1
+47 IF CNT=1
SET HLA("HLS",EN)=PID(CNT)
+48 IF CNT>1
SET HLA("HLS",EN,CNT-1)=PID(CNT)
End DoDot:1
+49 SET EN=EN+1
+50 ;**44 only pass PD1 segment if has values -- SENDING CMOR AGAIN AS WITHOUT 40 ON MPI SIDE THIS IS A PROBLEM.
IF $GET(PD1(1))'=""
SET HLA("HLS",EN)=PD1(1)
SET EN=EN+1
+51 ;**44 only pass PV1 segment if has values
IF $GET(PV1)'=""
SET HLA("HLS",EN)=PV1
SET EN=EN+1
+52 ;**44 only pass PV2 segment if has values
IF $GET(PV2)'=""
SET HLA("HLS",EN)=PV2
SET EN=EN+1
+53 ;**44 only pass RADIOLOGY IN OBX segment if has values
IF $GET(RAD)'=""
SET HLA("HLS",EN)=RAD
SET EN=EN+1
+54 ;**44 only pass LAB IN OBX segment if has values
IF $GET(LAB)'=""
SET HLA("HLS",EN)=LAB
SET EN=EN+1
+55 ;**44 only pass PRESCRIPTION IN OBX segment if has values
IF $GET(PRE)'=""
SET HLA("HLS",EN)=PRE
SET EN=EN+1
+56 ;**54,MVI_913: pass OLDER RECORD in OBX if flagged as such
IF $GET(OLD)'=""
SET HLA("HLS",EN)=OLD
SET EN=EN+1
+57 ;**59
IF $GET(SIDG)'=""
SET HLA("HLS",EN)=SIDG
SET EN=EN+1
+58 ;**60 MVI_4733 (ckn) Pass DOD fields in OBX
IF $GET(DODF)'=""
SET HLA("HLS",EN)=DODF
SET EN=EN+1
+59 ;**64 Story 323009 (ckn) : Pass additional DOD fields in OBX
+60 IF $GET(DODD)'=""
SET HLA("HLS",EN)=DODD
SET EN=EN+1
+61 IF $GET(DODOPT)'=""
SET HLA("HLS",EN)=DODOPT
SET EN=EN+1
+62 IF $GET(DODNP)'=""
SET HLA("HLS",EN)=DODNP
SET EN=EN+1
+63 ;**59,MVI_3975 (mko): pass NAME COMPONENTS in OBX
IF $GET(NAMECOMP)'=""
SET HLA("HLS",EN)=NAMECOMP
SET EN=EN+1
+64 ;**68,Story 783361 (ckn)- Security
IF $GET(SECLVL)'=""
SET HLA("HLS",EN)=SECLVL
SET EN=EN+1
+65 ;**78, VAMPI-11114 (dri)
IF $ORDER(SEXOR(0))
NEW CNT
SET CNT=0
FOR
SET CNT=$ORDER(SEXOR(CNT))
if 'CNT
QUIT
SET HLA("HLS",EN)=SEXOR(CNT)
SET EN=EN+1
+66 ;**78, VAMPI-11114 (dri)
IF $ORDER(SEXORD(0))
Begin DoDot:1
+67 NEW CNT,LVL
+68 SET LVL=1
SET CNT=0
FOR
SET CNT=$ORDER(SEXORD(CNT))
if 'CNT
QUIT
Begin DoDot:2
+69 IF CNT=1
SET HLA("HLS",EN)=SEXORD(CNT)
+70 IF CNT>1
SET HLA("HLS",EN,LVL)=SEXORD(CNT)
SET LVL=LVL+1
End DoDot:2
End DoDot:1
SET EN=EN+1
+71 ;**78, VAMPI-11118 (dri)
IF $ORDER(PRON(0))
NEW CNT
SET CNT=0
FOR
SET CNT=$ORDER(PRON(CNT))
if 'CNT
QUIT
SET HLA("HLS",EN)=PRON(CNT)
SET EN=EN+1
+72 ;**78, VAMPI-11118 (dri)
IF $ORDER(PROND(0))
Begin DoDot:1
+73 NEW CNT,LVL
+74 SET LVL=1
SET CNT=0
FOR
SET CNT=$ORDER(PROND(CNT))
if 'CNT
QUIT
Begin DoDot:2
+75 IF CNT=1
SET HLA("HLS",EN)=PROND(CNT)
+76 IF CNT>1
SET HLA("HLS",EN,LVL)=PROND(CNT)
SET LVL=LVL+1
End DoDot:2
End DoDot:1
SET EN=EN+1
+77 ;**44 ZPD SEGMENT
SET HLA("HLS",EN)=ZPD
SET EN=EN+1
+78 ;**59 ZSP segment
IF $GET(ZSP)'=""
SET HLA("HLS",EN)=ZSP
SET EN=EN+1
+79 ;**59 ZEL segment
IF $GET(ZEL)'=""
SET HLA("HLS",EN)=ZEL
SET EN=EN+1
+80 SET MPI=$$MPILINK^MPIFAPI()
+81 if $PIECE($GET(MPI),"^")=-1
QUIT "-1^No logical link defined for the MPI"
+82 ;**75 - Story - 1260465 (ckn) - Include 200M in HLL links for HAC
+83 SET HLL("LINKS",1)="MPIF ADT-A31 CLIENT^"_MPI_$SELECT($PIECE($$SITE^VASITE(),"^",3)=741:"^200M",1:"")
+84 DO GENERATE^HLMA("MPIF ADT-A31 SERVER","LM",1,.MPIFRSLT,"","")
+85 ;**68 Story 827754 (jfw) - Make Error Data Consistent (-1^msg)
SET RESLT=$SELECT(+MPIFRSLT:MPIFRSLT,1:"-1^"_$PIECE(MPIFRSLT,"^",3))
+86 SET ^XTMP("MPIFA31%"_DFN,0)=$$FMADD^XLFDT(DT,5)_"^"_DT_"^"_"MPIA31 msg to MPI for DFN "_DFN
+87 ;**68 Story 827754 (jfw) - Check for value < 0 instead of '+RESLT
IF +RESLT<0
SET ^XTMP("MPIFA31%"_DFN,"MPI",0)="A"
+88 KILL HLA,HLL("LINKS"),COMP,REP,SUBCOMP,HLA("HLA"),HLA("HLS"),MPIFRSLT
+89 ;**44 REMOVED HLEID, HLECH AND HLFS from Kill line above
+90 QUIT RESLT
+91 ;
RES ;
+1 NEW NXT,DFN,ERROR,CODE
SET CODE=""
+2 FOR NXT=1:1
XECUTE HLNEXT
if HLQUIT'>0
QUIT
Begin DoDot:1
+3 IF $EXTRACT(HLNODE,1,3)="MSA"
SET DFN=$PIECE($PIECE(HLNODE,HL("FS"),7),"=",2)
SET ERROR=$PIECE(HLNODE,HL("FS"),4)
SET CODE=$PIECE(HLNODE,HL("FS"),2)
+4 IF $EXTRACT(HLNODE,1,3)="MSA"&(CODE="AR")
Begin DoDot:2
+5 ; ERROR RETURNED IN MSA - LOG EXCEPTION
+6 DO START^RGHLLOG(HLMTIEN,"","")
+7 ;**44 check which type of exception to be logged
+8 ;**46
DO EXC^RGHLLOG(234,ERROR,DFN)
+9 DO STOP^RGHLLOG(0)
End DoDot:2
End DoDot:1
+10 ;**54,MVI_913: Delete the old record designation
if $GET(DFN)>0
KILL ^XTMP("MPIF OLD RECORDS",DFN)
+11 KILL ^XTMP("MPIFA31%"_DFN)
+12 QUIT
+13 ;
OLD() ; Return OBX segment to flag a record as "old"
+1 ;**54,MVI_913: New subroutine
+2 QUIT $SELECT($DATA(^XTMP("MPIF OLD RECORDS",DFN))#2:"OBX"_HL("FS")_HL("FS")_"CE"_HL("FS")_"OLDER RECORD"_HL("FS")_HL("FS")_"Y",1:"")
+3 ;