VERSION |
-
- 2.0
- DATE DISTRIBUTED: 2002-11-12 00:00:00
- PATCH APPLICATION HISTORY:
-
-
- 3
- DATE APPLIED: 1997-04-17 00:00:00
- APPLIED BY: USER,ONE
- DESCRIPTION:
During the New Clinic Visits option, some QUASAR users may see an
others do not? Recent FileMan patches clean up the utilities
for creating and entering data in sub-files (FILE^DICN and DIE).
We believe the QUASAR problem shows up after the FM patches are
installed.
The legacy QUASAR code used old methodology for this call and
needed to be updated. Patch ACKQ*2*3 corrects this problem.
What is the impact of this bug on QUASAR data? Depending on how
the Select DIAGNOSTIC CONDITION prompt is answered, the patient
additional prompt while entering the DIAGNOSTIC CODE(s). This
diagnostic history in the A&SP PATIENT file (#509850.2) may not
be complete. It is advisable to use the Inquire - A&SP Patient
option to update the diagnostic history.
additional prompt is Select DIAGNOSTIC CONDITION. The prompt
occurs after the diagnostic code has been entered into the A&SP
CLINIC VISIT file (#509850.6) and while the A&SP PATIENT file's
(#509850.2) diagnostic condition multiple (patient diagnostic
history) is being updated.
Why do some QUASAR users see this additional prompt, while
-
- 4
- DATE APPLIED: 1997-07-17 00:00:00
- APPLIED BY: USER,ONE
- DESCRIPTION:
The AMIE C&P AUDIO worksheet (#1305) format has been
reconfigured. The worksheet headings and organization have
changed. Patch ACKQ*2*4 corrects this for QUASAR.
Additionally, this patch replaces all "W *7" code with "W $C(7)"
in nine (9) QUASAR routines and in the ACKQAS VISIT ENTRY input
template on the A&SP CLINIC VISIT file (#509850.6).
-
- 5
- DATE APPLIED: 1997-08-08 00:00:00
- APPLIED BY: USER,ONE
- DESCRIPTION:
When a C&P exam is adequated in QUASAR, the results are
transmitted to the AMIE C&P software. If the transmission
attempt to AMIE fails and the data is not successfully sent,
QUASAR currently does not leave the visit in a "signed off on,
but not adequated" state. This patch corrects this problem by
leaving the visit in a "signed off on, but not adequated" state
so that re-transmission can take place.
-
- 6
- DATE APPLIED: 1997-09-22 00:00:00
- APPLIED BY: USER,ONE
- DESCRIPTION:
This patch corrects a problem reported in NOIS CTX-0997-70706.
After installing ACKQ*2*5, sites reported that the adequator
signature block does not print on the AMIE report. Patch
ACKQ*2*6 corrects this problem.
-
- 7
- DATE APPLIED: 1998-04-03 00:00:00
- APPLIED BY: USER,ONE
- DESCRIPTION:
Y2K COMPLIANCE PATCH
-
- 8
- DATE APPLIED: 1998-12-29 00:00:00
- APPLIED BY: USER,ONE
- DESCRIPTION:
See description of patch on FORUM.
-
- 9 SEQ #9
- DATE APPLIED: 1999-07-19 00:00:00
- APPLIED BY: USER,ONE
- DATE INSTALLED AT THIS SITE: 1996-09-26 00:00:00
- INSTALLED BY: USER,ONE
- DESCRIPTION OF ENHANCEMENTS:
Quality: Audiology and Speech Pathology Audit and Review (QUASAR) is
designed to capture patient treatment and workload information for
Audiology and Speech Pathology clinic visits.
-
- 3.0
- DATE DISTRIBUTED: 2005-11-19 00:00:00
- PATCH APPLICATION HISTORY:
-
-
- 1 SEQ #1
- DATE APPLIED: 2001-01-22 00:00:00
- APPLIED BY: USER,ONE
-
- 10 SEQ #10
- DATE APPLIED: 2006-02-13 00:00:00
- APPLIED BY: USER,ONE
- DESCRIPTION:
This patch will correct to problem with in QUASAR
that allows the user to create a new visit for
deceased patients.
-
- 15 SEQ #11
- DATE APPLIED: 2007-09-04 22:38:13
- APPLIED BY: USER,ONE
- DESCRIPTION:
INCORRECT DIAGNOSTIC CODE DISPLAY
-
- 13 SEQ #12
- DATE APPLIED: 2007-09-05 00:58:38
- APPLIED BY: USER,ONE
- DESCRIPTION:
Interface of Medical Devices with QUASAR and the DALC.
-
- 14 SEQ #13
- DATE APPLIED: 2007-12-12 20:43:46
- APPLIED BY: USER,ONE
-
- 17
- DATE APPLIED: 2010-10-27 11:29:05
- APPLIED BY: USER,SEVENTEEN
- DESCRIPTION:
This patch will correct a problem with broken pointers.
Associated Remedy
HD147036 - Quasar Patch ACKQ*3*9 - Amendments for Scheduling
-
- 16 SEQ #15
- DATE APPLIED: 2010-11-10 12:24:51
- APPLIED BY: USER,SEVENTEEN
- DESCRIPTION:
This patch addresses the following issues:
needs to have the default changed from "NULL" to "YES".
1. From the New Clinic Visits [NEW CLINIC VISITS ACKQAS VISIT ENTRY]
menu option, when checking out a patient that has the Combat
Classification, the prompt does not display allowing the user to
answer the Combat questions for the visit.
2. At each episode of care, the prompt to determine if the care
provided is related to the combat experience of the OEF/OIF veteran
-
- 18 SEQ #16
- DATE APPLIED: 2011-04-04 14:23:39
- APPLIED BY: USER,SEVENTEEN
- DESCRIPTION:
As a follow up to patch LEX*2.0*64 modifications are necessary to
all references of the newly deleted fields and use of the
corresponding API's is required to acquire the necessary
information.
-
- 22 SEQ #17
- DATE APPLIED: 2013-12-12 14:13:10
- APPLIED BY: USER,SEVENTEEN
- DESCRIPTION:
This patch addresses one issue:
This patch will update all direct file reads to the ICD DIAGNOSIS (#80)
file,CPT MODIFIER (#81.3) file, and the CPT FILE (#81) file in the Quasar
application to the new associated API's.
-
- 21 SEQ #18
- DATE APPLIED: 2014-09-02 12:54:12
- APPLIED BY: USER,SEVENTEEN
- DESCRIPTION:
ICD-10 Remediation patch for QUASAR
-
- 2 SEQ #2
- DATE APPLIED: 2001-04-12 00:00:00
- APPLIED BY: USER,ONE
-
- 4 SEQ #3
- DATE APPLIED: 2002-11-08 00:00:00
- APPLIED BY: USER,ONE
- DESCRIPTION:
Fix event capture error's.
-
- 5 SEQ #4
- DATE APPLIED: 2003-03-29 00:00:00
- APPLIED BY: USER,ONE
- DESCRIPTION:
This patch fixes the problem with updating diagnosis histories in the
A&SP Patient file (#509850.2).
-
- 7 SEQ #5
- DATE APPLIED: 2003-07-15 00:00:00
- APPLIED BY: USER,ONE
- DESCRIPTION:
This patch fixes problems with the updating of the Problem List via the
PCE interface.
-
- 6 SEQ #6
- DATE APPLIED: 2003-09-24 00:00:00
- APPLIED BY: USER,ONE
- DESCRIPTION:
Please see the National Patch Module for details of the enhancements
included in this patch.
-
- 3 SEQ #7
- DATE APPLIED: 2003-11-07 00:00:00
- APPLIED BY: USER,ONE
- DESCRIPTION:
The Audiometric module was developed in conjunction
509850.9<tab>AUDIOMETRIC EXAM<tab>^ACK(509850.9
2. New options introduced with this patch:
ACKQROES3<tab>Audiogram Display
Uses new remote procedure call: ACKQAUD1. See Option file
entries to see other existing XWB, XUS, and DDR RPCs
accessed.
(1) [ACKQROES3E] Enter or edit the data into file 509850.9. When
ACKQROES3E<tab>Audiogram Data Edit
Uses new remote procedure calls: ACKQROES and ACKQAUD2.
See Option file entries to see other existing XWB, XUS,
and DDR RPCs accessed.
3. New remote procedure introduced with this patch:
ACKQAUD1: returns array of data for last 2 exams
Uses routines: ACKQAG01 and ACKQAG06
signed, this transmits the data to the DDC for use with ROES 3
ACKQAUD2: returns array of data for a specific exam
Uses routine: ACKQAG02
ACKQROES: transmits data to DDC & returns msg#, DDC msg#,
error# and error msg.
Uses routines: ACKQAG03, ACKQAG04 and ACKQAG05
Installation Instructions:
=========================
Custom Hearing Aid orders.
This patch was created with Kernel V8 KIDS.
1. This is a completely new installation, so it will not affect
any current ROES 3 users or others on the system. You do not
need to restrict users from signing on or lock any options.
2. Use the 'INSTALL/CHECK MESSAGE' option on the PackMan menu.
This option will load the KIDS package onto your system.
3. You DO NOT need to stop Taskman or the background filers. None
of the routines require mapping, so mapping does not need to be
disabled.
4. Using the Kernel Installation and Distribution System menu
(KIDS), you may choose the following options prior to
installing this patch:
a) All routines are new, so there should be no need to Backup
the Transport Global.
(2) [ACKQROES3] View the audiogram generated from that data and
b) Again, this is an all new module, so there should be no
need to Compare Transport Global to the Current System.
c) Verify Checksums in the Transport Global. This option will
allow you to ensure the integrity of the routines that are
in the transport global.
5. Use the 'Install Package(s)' option under the 'Installation'
menu. Installation should only take a few minutes.
print VA form 10-2364.
a) Select INSTALL NAME: ACKQ*3.0*3
b) When prompted 'Want KIDS to Rebuild Menu Trees Upon
Completion of Install?' YES// respond "NO"
c) When prompted 'Want KIDS to INHIBIT LOGONs during the
install?' YES// respond "NO".
d) When prompted 'Want to DISABLE Scheduled Options, Menu
Option and Protocols?' NO// respond "NO".
e) When prompted 'Want to MOVE routines to other CPUs?' YES//
respond "NO".
6. Unzip the Audiogram.zip file containing the executables
ACKQROES3.EXE and ACKQROES3E.EXE onto the network. They must
reside in the same directory in order for the practitioner to
view the audiogram display(ACKQROES3) from the audiogram edit
program (ACKQROES3E). [An alternative is to place the
executables on each client computer, referencing it in the
NOIS references addressed in this patch
application path of the CPRS Tools menu.]
7. Assign Broker options ACKQROES3 and ACKQROES3E to selected ASPS
staff members. This will provide access to the options and
allow them to startup successfully when the user logs in.
8. Add the ACKQROES3 and ACKQROES3E applications to the CPRS Tools
menu. [See the separate installation guide for further
instructions.]
=======================================
with the Remote Order Entry System (ROES 3.0) at the VA Denver
There are no NOIS or E3R references.
Test Sites
==========
Denver
New York
Columbia
Mountain Home
Atlanta
Nashville
Distribution Center. [Prior ROES 2 VistA applications may be run
FTP Software and Documentation
==============================
This patch will be distributed in a PackMan message through the
National Patch Module and should be obtained from there.
The KIDS build for this patch is ACKQ*3.0*3.
KIDS File (ACKQ*3.0*3): ACKQ_3_P3.KID
ZIP file of executables: AUDIOGRAM.ZIP
Documentation:
concurrently with the new system during the switchover]
ACKQ_3_P3_IG.PDF Installation guide
ACKQ_3_P3_SG.PDF Security guide
ACKQ_3_P3_TM.PDF Technical manual
ACKQ_3_P3_UM.PDF User manual
Note: The .PDF and .ZIP files are binary files and must be
transferred in binary, not ASCII mode. These files can be read
using the Adobe Acrobat Reader program.
This patch contains the following enhancements:
This patch includes two new options. These two options are only
==============================================
The Audiometric Exam Module (ACKQ*3.0*3) provides new
functionality for ASPS, to simplify and enhance the entry, display
and use of information obtained during the Audiometric exam of
a patient. This module is comprised of two distinct application
functions: Audiogram Edit function and the Audiogram Display
function.
Records are stored in a local QUASAR global (#509850.9).
available in the Windows environment. Please refer to the
When signed they are also transmitted from this application to the
Denver Distribution Center (DDC) through the VistA MailMan system
for inclusion with orders for hearing aids and repairs when
ordered through the VistA Remote Order Entry System (ROES)
package.
The 'Audiogram Edit' function is a Windows based software
application that allows clinicians to enter, edit or view the
audiometric exam information from the Computerized Patient
Record System (CPRS) Tools menu. Using this function, a new
Installation Guide for instructions on setting these options up.
audiogram record can be entered, or an existing one can be edited.
Once signed, the edited data can only be viewed.
The 'Audiogram Display' function is a Windows based software
application that allows clinicians to view a patient's audiogram
from the CPRS Tools menu. It can also be called from the
Audiogram Edit application, if they exist in the same directory
and folder. This function presents the clinical information in a
standard format recognized within the hearing industry. The user
has a choice of viewing just the last audiogram, or the last two
in the file.
ROUTINE SUMMARY
===============
The second line of all listed routines will look like:
<tab> ;;3.0;QUASAR AUDIOMETRIC MODULE;**3**;11/01/02
CHECK^XTSUMBLD results:
ACKQAG01<tab>N/A<tab>9433779<tab>3
The 2 new GUI options are:
ACKQAG02<tab>N/A<tab>14506291<tab>3
ACKQAG03<tab>N/A<tab>4940176<tab>3
ACKQAG04<tab>N/A<tab>133577359<tab>3
ACKQAG05<tab>N/A<tab>1171193<tab>3
ACKQAG06<tab>N/A<tab>12622668<tab>3
Technical Description
=====================
1. New file introduced with this patch:
-
- 8 SEQ #8
- DATE APPLIED: 2004-10-15 00:00:00
- APPLIED BY: USER,ONE
- DESCRIPTION:
Updates for Code Text Versioning.
-
- 12 SEQ #9
- DATE APPLIED: 2006-01-12 00:00:00
- APPLIED BY: USER,ONE
- DESCRIPTION:
The Audiometric Exam Module was developed in conjunction with the Remote
3. Comments
A comment box has been added to the Edit application where the clinician
can enter up to 300 characters of text. A checkbox has been inserted
directly above the comment area for use if the clinician would like to
automatically insert the words "NOT ADEQUATE FOR RATING PURPOSES". This
text will be saved to the file and will be imported into VA form 10-2364.
4. Update VA form 10-2364
VA form 10 2364 has been modified to reflect the changes made to the form
Order Entry System (ROES 3.0) at the VA Denver Distribution Center(DDC)
since the release of patch ACKQ*3.0*3. The comment section of the form is
no longer editable.
5. Color Changes
Color has been removed from the data entry boxes. This allows for a
cleaner presentation and makes more of the screen available for the edit
boxes.
6. Retransmit Audiogram
In the Edit application, a menu option has been added to allow
and is only available to run in the Windows environment. The application
retransmission of a signed audiogram. This is necessary to transfer the
speech, word and other readings that were not a part of the original
transmission.
7. Removing Audiogram
In the Edit application, a menu option has been added to allow deletion
of a signed audiogram. This became necessary because, in their haste to
enter audiograms under heavy workload pressures, users sometimes entered
audiograms under the wrong patient and the error was not discovered until
after transmission. This would then become a problem when data would be
can be installed completely from this patch, if ACKQ*3.0*3 was not
on duplicate systems for the wrong patient. After installing this patch,
when a local signed audiogram is deleted, a message with identifying
information is sent to the DDC to delete the record there also.
Clinicians should use utmost caution in both entering and removing
audiograms.
8. File Changes
Numerous fields were added to the AUDIOMETRIC EXAM file to provide the
additional data needed for diagnostic and reporting purposes. The data
type of many fields was changed at the request of the national program
installed. Users are encouraged to consult the full Installation Guide
office to more efficiently handle the text and tags required in the
fields. Many that were numeric are now free text. Refer to the
CHANGES/ADDITIONS TO FILE section for more detailed information.
9. New Fields on Edit Pages
The new editable fields (bullet 8) and data type screening were added to
the Edit program.
10. Masking Change
Masking is no longer referenced in the fields with an '*', but will
referenced below if AKCQ*3.0*3 was not installed. If ACKQ*3.0*3 was
instead be indicated by a non-zero numeric value in the 'Masking Level'
field. Prior instances of the data without a masking level will continue
to display the '*' sign.
11. No Response Change
The symbol for 'No Response'(+) will now be stored in the text field with
the numeric value.
12. No Testing, No Masking
'CNM', 'CNT', 'DNT' and 'FLAT; are now accommodated in the appropriate
text fields in the file as well as in the Edit program.
13. Transducer Type
Users can now indicate if testing was done via inserts or headphones.
This is also displayed on the 10-2364.
14. Eliminate Duplicate Presentation and Material
One selection of the Presentation Method and Material are now applicable
to all of the Word Recognition tests, via a single drop down list.
installed, then installing the KIDS build and copying the new executables
15. Tympanogram Type and Other Test
Tympanogram Type and 'Other Test' types have been added to the Acoustic
Immittance page.
16. Claim Number
The Claim Number has been added to the Edit form so that it can be
included on VA form 10-2364.
17. Maximum Value Change
Maximum values allowed have been updated and associated 'Hints' have been
adjusted.
18. Hints
It is now possible for the user to inactivate or reactivate the hint
feature.
19. Clinician Title
The title of the clinician and location will now show on the display.
20. Presentation Method
over the original executables of the same name will complete
CD and Tape have been consolidated into a single Recorded type.
21. About Box
An 'About' box was added to the main forms to comply with VistA
convention.
Software and Documentation Retrieval
====================================
This patch addresses several issues that came up at the VAMC stations as
the install.
The software and documentation for this patch can be found in the
following [ANONYMOUS.SOFTWARE] directories:
Preferred Address
----------------------
First available FTP server download.vista.domain.ext
Specific Field Office FTP address
--------------------- -----------
Albany ftp.fo-albany.domain.ext
Hines ftp.fo-hines.domain.ext
Salt Lake City ftp.fo-slc.domain.ext
File Name Description Format FTP Protocol
----------------- ------------- ------ ------------
ACKQ_3_P12_RN.PDF Release notes PDF Binary
ACKQ_3_P12_IG.PDF Installation Guide PDF Binary
ACKQ_3_P12_UM.PDF User Manual PDF Binary
REMEDY ticket(s) addressed in this patch
ACKQ_3_P12_TM.PDF Technical manual PDF Binary
ACKQ_3_P3_SG.PDF Security guide PDF Binary
ACKQ_3_P12.KID KIDS build KIDS ASCII
AUDIOGRAM_P12.ZIP Executables ZIP Binary
Test Sites
==========
Columbia(SC)
========================================
Las Vegas
Miami
Tennessee Valley
New York
Salisbury
Fayetteville AR
ROUTINE SUMMARY:
================
HD000000063808
The following is a list of the routines included in this patch.
The second line of each of these routines now looks like:
<tab>;;v 3.0;QUASAR AUDIOMETRIC EXAM MODULE;**[patch list]**;11/01/02
CHECK1^XTSUMBLD results
Routine Name Before Patch After Patch Patch List
HD000000063675
============ ============ =========== ==========
ACKQAG01 49470887 69211169 ** 3,12 **
ACKQAG02 61779051 62617084 ** 3,12 **
ACKQAG03 11574717 11560534 ** 3,12 **
ACKQAG04 65019411 68097423 ** 3,12 **
ACKQAG05 1840641 19012760 ** 3,12 **
ACKQAG06 47277438 63053336 ** 3,12 **
ACKQAG08 n/a 38815781 ** 12 **
HD000000063875
INSTALLATION INSTRUCTIONS:
==========================
Installation of this patch will take about 5 minutes. Additional
time will be needed if the GUI applications have been installed on
individual client machines or the location of the applications on the
network has changed. Users need not be off the system when applying this
patch, but it should be installed during non-peak hours to minimize
disruption to users.
HD000000063682
1. On the KIDS menu under the 'INSTALLATION' menu, use the following
options as desired:
Print Transport Global
Compare Transport Global to Current System
Verify Checksums in Transport Global
Backup a Transport Global
2. On the KIDS menu under the 'INSTALLATION' menu, use the following
option to install the patch:
Install Package(s) (ACKQ*3.0*12)
3. When prompted "Want KIDS to Rebuild Menu Trees Upon Completion of
Install? YES//", respond 'NO'.
4. When prompted "Want KIDS to INHIBIT LOGONs during the install? YES//"
respond 'NO'.
5. When prompted 'Want to DISABLE Scheduled Options, Menu Options, and
Protocols? YES//', respond 'YES'.
Overview of Remedy ticket(s):
Options to disable:
ACKQROES3
ACKQROES3E
6. When prompted 'Delay Install (Minutes): (0-60): 0//; respond '0'.
7. Following the installation of the KIDS build, the system will
immediately run routine ACKQAG08. This will move any existing
'No Response' or 'Masked' tags into the appropriate threshold fields.
a result of the initial release of the Audiometric Exam Module (patch
----------------------------
8. At this point the two revised executables (ACKQROES3.EXE and
ACKQROES3E.EXE) should be copied over all existing copies on the
network or client machine. Add the VistA menu options for any new
application users and setup on their CPRS Toolbar as necessary, as
detailed in the INSTALLATION GUIDE.
9. We do not anticipate any need to reinstall this patch. However, it
may be reinstalled if necessary.
Problem: When a user without context accessed the Edit Module, they were
allowed to enter the application and view the screens. They were not able
to actually edit the data.
Solution: The application [ACKQROES3E.EXE] was modified to exit and halt
the application if the user did not have the appropriate VistA
application assigned to create context.
Associated Remedy Ticket: HD000000063808
ACKQ*3.0*3). These changes have been made to the GUI(Windows based)
-----
Problem: Sites encountered a Null Subscript at EN2+4^ACKQAG02 when
entering a new record and cancels out of entering the date and time of
the exam.
Solution: A fix is applied in routine ACKQAG02 and in the record setup
to give the appropriate error message and exit the application if a valid
Enter/Edit(ACKQROES3E.EXE) and Display(ACKQROES3.EXE) applications in the
date and time are not entered.
Associated Remedy Tickets: HD000000063675 and HD000000063875
-----
Problem: Some error messages or message prompts were coming up behind
other screens. The only way for them to show up was to select the
application from the bottom task bar.
Solution: Most of the messages in the Audiogram Edit application are now
package for both the CPRS Toolbar and Desktop versions, as well as to the
enclosed in code to send them to topmost position and after the message
ends, to restore the previous topmost setup. This may not be a complete
solution, but available documentation indicates it should help, if not
eliminate the problem from this application.
Associated Remedy Ticket: HD000000063682
-----
VistA part of the application. The VistA part includes the file data
This patch contains the following enhancements:
===============================================
The Audiometric Exam Module provided new functionality for Audiology and
Speech Pathology Services(ASPS), to simplify and enhance the entry,
display and use of information obtained during the Audiometric exam of a
patient. This module is comprised of two distinct application functions:
Audiogram Edit function [ACKQROES3E.EXE]
Audiogram Display function [ACKQROES3.EXE]
dictionary, Remote Procedure Calls and routines.
Records are stored in the local AUDIOMETRIC EXAM file (^ACK(509850.9).
When signed, the records are also transmitted from this global to the DDC
through the VistA Mailman system. At the DDC, data from these records is
included with orders for hearing aids and repairs when the orders are
placed through the VistA Remote Order Entry System (ROES) package.
They may also be viewed remotely from the ROES Patient Information screen
of the ROES web application.
ACKQ*3.0*12 implements the following changes:
1. Removal of Buttons
In both audiogram GUI applications, the buttons previously on the screens
have been replaced by menu options at the top of the form.
2. Loop to Another Patient or Record
In both applications, a menu option (Get New Record) has been added to
allow the user to go to another record without exiting the application.
If accessing through CPRS, record selection is limited to the current
patient. From the Desktop application, users may select another patient
or go to another record for the same patient.
- DATE INSTALLED AT THIS SITE: 2000-06-26 00:00:00
- INSTALLED BY: USER,ONE
- DESCRIPTION OF ENHANCEMENTS:
TEST INSTALL VERSION 3
|