VERSION |
-
- 1.0
- DATE DISTRIBUTED: 2009-04-23 00:00:00
- PATCH APPLICATION HISTORY:
-
-
- 1
- DATE APPLIED: 2009-06-09 15:35:33
- APPLIED BY: USER,SEVENTEEN
- DESCRIPTION:
This patch is being released in support of the VBECS (VistA Blood
Installation and User Guide.doc
Blood Bank Pre-Implementation Data Validation, Mapping, and Conversion
Installation and User Guide.pdf
Blood Bank Pre-Implementation Data Validation, Mapping, and Conversion
Technical Manual.doc
Blood Bank Pre-Implementation Data Validation, Mapping, and Conversion
Technical Manual.pdf
VBECS Data Conversion Recommended Validation Method.xls
VBECS Application Interfacing Support Software Installation and User
Configuration Guide.doc
Options: VBECS VISTALINK CONTEXT
VBECS Application Interfacing Support Software Installation and User
Configuration Guide.pdf
VBECS Implementation Process.xls
VistA Blood Establishment Computer Software (VBECS) 1.4.0.0 Installation
Guide.doc
VistA Blood Establishment Computer Software (VBECS) 1.4.0.0 Installation
Guide.pdf
VistA Blood Establishment Computer Software (VBECS) 1.4.0.0 Technical
Manual-Security Guide.doc
VistA Blood Establishment Computer Software (VBECS) 1.4.0.0 Technical
========
Manual-Security Guide.pdf
VistA Blood Establishment Computer Software (VBECS) 1.4.0.0 User Guide.doc
VistA Blood Establishment Computer Software (VBECS) 1.4.0.0 User Guide.pdf
Known Defects and Anomalies.doc
Known Defects and Anomalies.pdf
Installation Instructions:
==========================
This patch may be loaded with users on the system.
Installation will take less than 5 minutes.
1) Use the 'LOAD A DISTRIBUTION' option on the KIDS Installation
menu. The Host File name is VBEC_1_1.KID . Answer YES to the
question: "Want to Continue with Load? YES//"
2) From the Kernel Installation and Distribution System Menu,
select the Installation menu.
3) From this menu, you may elect to use the following options
(when prompted for the INSTALL NAME, enter VBEC*1.0*1).
a) Backup a Transport Global - this option will create a backup
message of any routines exported with the patch. It will NOT
backup any other changes such as DDs or templates.
b) Compare Transport Global to Current System - this option will
allow you to view all changes that will be made when the patch
is installed. It compares all components of the patch
(routines, DDs, templates, etc.).
c) Verify Checksums in Transport Global - this option will allow
you to ensure the integrity of the routines that are in the
transport global.
d) Print Transport Global - this option will allow you to view the
Protocols: VBEC OMG CLIENT
components of the KIDS build.
4) Use the Install Package(s) option and select the package
VBEC*1.0*1.
5) When prompted 'Want KIDS to Rebuild Menu Trees Upon Completion of
Install? NO//' respond YES
6) When prompted 'Want KIDS to INHIBIT LOGONs during the install?
NO//', respond NO.
7) When prompted 'Want to DISABLE Scheduled Options, Menu Options, and
Protocols? NO//', respond NO.
==========
Remote Procedures: VBEC DSS EXTRACT
==================
Establishment Computer System) Blood Bank Package. The routines,
Files: VBECS DSS EXTRACT (# 6002.03)
======
Associated ICRs: None
===============
Associated Remedy Tickets: None
protocols, remote procedures, and options in this patch are used by the
==========================
Associated NSR/E3R: None
==============
Test Site(s):
==============
HEARTLAND-EAST HCS
DSS (Decision Support System) and CPRS (Computerized Patient Record
PHILADELPHIA, PA
SAN DIEGO, CA
Installation Information:
==========================
VBEC*1*1 is being exported as part of the VBECS package release. The
installation of VBEC*1*1 will be controlled by phase a phased release.
An Implementation Manager will be assigned to your site and will contact
your POC for VBECS and will provide your site with the location of the
System). There is no direct user interaction with the contents of this
KIDS Host Files prior to your scheduled installation date.
Installation Sequence
=====================
The patches listed below represent those that will be part of the
controlled phased release. Follow the sequence listed below when your
phased installation occurs.
1. LR*5.2*335
patch.
2. LR*5.2*367
3. VBECS Bundle (consisting of VBEC*1*0 and LR*5.2*325)
4. VBEC*1.0*1
5. OR*3.0*212
Installation File:
VBEC_1_1.KID
The VBEC_1_1.KID file will be made available by the Implementation
Manager prior to your site's implementation schedule along with
instruction to retrieve.
Documentation Retrieval:
Documentation is available for the entire VBECS package on the
ANONYMOUS.SOFTWRE directory at one of the following Office of Information
(OI) Field Offices. Sites may retrieve documentation in either ".PDF" or
"DOC" format in one of the following ways:
Routines: VBECDSS
1. The preferred method is to FTP the files from :
Download.vista.domain.ext
2. Sites may also elect to retrieve documentation directly from a
specific server as follows:
Albany ftp.fo-albany.domain.ext
Hines ftp.fo-hines.domain.ext
Salt Lake City ftp.fo-slc.domain.ext
NOTE: The documentation files listed below will be listed in each of the
======== VBECHLOR
VBECS and LR patches that are part of the VBECS package and associate
patches, they only need to be downloaded once.
File Name Retrieval format: Binary
=========== ==========================
Blood Bank Pre-Implementation Data Validation, Mapping, and Conversion
ADPAC Guide.doc
Blood Bank Pre-Implementation Data Validation, Mapping, and Conversion
ADPAC Guide.pdf
Blood Bank Pre-Implementation Data Validation, Mapping, and Conversion
-
- 0
- DATE APPLIED: 2009-01-30 00:00:00
- DESCRIPTION:
This patch is part of the VBECS BUNDLE 1.0 controlled release. See the
description for the VBECS BUNDLE 1.0 for patch details.
-
- 3
- DATE APPLIED: 2010-09-02 10:30:52
- APPLIED BY: USER,SEVENTEEN
- DESCRIPTION:
This patch contains changes to the VBECS Blood Bank package. Refer to the
patch listed in the Forum patch module for more details.
-
- 10
- DATE APPLIED: 2011-03-09 15:12:50
- APPLIED BY: USER,SEVENTEEN
- DESCRIPTION:
This patch contains changes to the VBECS Blood Bank package. Refer to the
patch listed in the Forum patch module for more details.
-
- 27
- DATE APPLIED: 2012-09-24 15:25:57
- APPLIED BY: USER,SEVENTEEN
-
- 56 SEQ #57
- DATE APPLIED: 2013-06-19 12:39:14
- APPLIED BY: USER,SEVENTEEN
-
- 54 SEQ #82
- DATE APPLIED: 2015-06-08 11:44:47
- APPLIED BY: USER,SEVENTEEN
- DESCRIPTION:
VBEC*1*54 is exported as part of the VistA Blood Establishment Computer
Therefore, to allow adequate time for impact analysis and testing the
VBECRPCC
DATA DICTIONARY:
================
N/A
REMEDY TICKETS:
===============
INC000000923654
INC000000925197
changes prior to installation in Production, it is imperative that Office
INC000000948143
TEST SITES:
===========
Durham, NC
Heartland-East HCS
>Marion, IL
>Poplar Bluff, MO
>St. Louis, MO
Milwaukee, WI
of Information Technology (OIT) Field Operations coordinate the
San Diego, CA
San Francisco, CA
Documentation:
==============
Documentation is available for the VBECS package on the
ANONYMOUS.SOFTWARE directory at one of the following Office of
Information (OI) Field Offices. Sites will be able to utilize
Documentation in either the ".PDF" or "DOCX" format after they extract
the ZIP file.
installation of Blood Bank software patches with Pathology & Laboratory
The preferred method is to FTP the files from:
Download.vista.domain.ext
This transmits files from the first available FTP server. Sites may also
elect to retrieve documentation directly from a specific server as
follows:
Albany ftp.fo-albany.domain.ext
Hines ftp.fo-hines.domain.ext
Salt Lake City ftp.fo-slc.domain.ext
Medicine Service staff.
NOTE: The ZIP file listed below will be listed in each of the
VBECS and LR patches that are part of the VBECS package and associated
patches. It only needs to be downloaded once.
File Name Retrieval format:
=========== =================
VBECS_2_0_0_DOCS_BUNDLE.ZIP BINARY
The following files are contained in the VBECS_2_0_0_DOCS_BUNDLE.ZIP file
and will not be individually located on the OI Field Office Anonymous
Directories.
The VBECS_2_0_0_DOCS_BUNDLE.ZIP file needs to be extracted on your
system for use.
=======================================================================
Veterans Health Administration (VHA) Customer Documents:
VistA Blood Establishment Computer Software (VBECS) 2.0.0 Release
The VBEC*1*54 patch addresses several issues. Refer to the sample
Notes.docx
VistA Blood Establishment Computer Software (VBECS) 2.0.0 Release
Notes.pdf
VistA Blood Establishment Computer Software (VBECS) 2.0.0 Technical
Manual-Security Guide.docx
VistA Blood Establishment Computer Software (VBECS) 2.0.0 Technical
Manual-Security Guide.pdf
VistA Blood Establishment Computer Software (VBECS) 2.0.0 User Guide.docx
VistA Blood Establishment Computer Software (VBECS) 2.0.0 User Guide.pdf
VBECS Known Defects and Anomalies.docx
validation scenarios listed with the correction to verify changes:
VBECS Known Defects and Anomalies.pdf
Installation Instructions:
==========================
This patch may be loaded with users on the system.
Installation will take less than 5 minutes.
1) Use the INSTALL/CHECK MESSAGE option on the PackMan menu to unload
the KIDS distribution included with this message.
2) From the Kernel Installation and Distribution System Menu,
select the Installation menu.
3) From this menu, you may elect to use the following options
(when prompted for the INSTALL NAME, enter VBEC*1.0*54).
a) Backup a Transport Global - this option will create a backup
message of any routines exported with the patch. It will NOT
backup any other changes such as DDs or templates.
b) Compare Transport Global to Current System - this option will
allow you to view all changes that will be made when the patch
is installed. It compares all components of the patch
(routines, DDs, templates, etc.).
1. 109 VistA MR 103013 - The CPRS Blood Bank Report, Diagnostic Tests
c) Verify Checksums in Transport Global - this option will allow
you to ensure the integrity of the routines that are in the
transport global.
d) Print Transport Global - this option will allow you to view
the components of the KIDS build.
4) Use the Install Package(s) option and select the package
VBEC*1.0*54.
5) When prompted 'Want KIDS to INHIBIT LOGONs during the install?
NO//' respond NO
6) When prompted 'Want to DISABLE Scheduled Options, Menu Options,
System (VBECS) Version 2.0.0 release.
Section has displayed Transfusion Reaction Workup test results
and Protocols? NO//' respond NO.
with patient Type and Screen test results. This was not done by
the legacy blood bank system. The change made to the VBECA1B1
routine will eliminate Transfusion Reaction Workup test results
from the Blood Bank Report, Diagnostic Tests Section. Note - the
Transfusion Reactions Section of the CPRS Blood Bank Report does
not change and will still display Transfusion Reaction
Interpretations.
Associated Remedy Tickets: INC000000923654 and INC000000925197.
Verification: Locate a patient with a Transfusion Reaction in VBECS.
Using this patient run the CPRS Blood Bank Report and note that
transfusion reaction testing is visible in the Diagnostic Tests
Section and the Transfusion Reactions Section has an interpretation.
Install VBEC*1*54. Repeat the lookup of the CPRS Blood Bank Report
and verify that the transfusion reaction testing is absent in the
CPRS Blood Bank Report, Diagnostic Tests Section. Verify that the
Transfusion Reactions Section of the CPRS Blood Bank Report does
not change and still displays the Transfusion Reaction
Interpretations after VBEC*1*54 is installed.
To meet Food & Drug Administration (FDA) requirements, VBECS related
2. 110 VistA MR 121713 - VBECS was able to accept a specimen when the
CPRS order was assigned a Lab accession number as the order was
added to a collection list and the specimen was not collected (no
collection date/time). This change requires that the specimen
accession number must also have a collection date and time in VistA
before it can be used in VBECS for processing.
Remedy Ticket: INC000000948143
VistA (Veterans Health Information Systems Technology Architecture)
Verification: Attempt to accept a VBECS order with a blood bank
specimen that does not have a collection date and time assigned in
VistA but has been assigned an accession number per a Lab collection
list. VBECS will allow processing of the specimen UID for an order
only when the specimen has a date and time collected assigned after
VBEC*1*54 is installed.
3. 111 VistA MR 061214 - The release of ICD*18.0*57 started a
retirement countdown for ICR 3990 used to lookup ICD codes. This
lookup is used by the LRBLPCH (Patient transfusions & hematology
patches require customer validation in local Test accounts prior to
results) option in VistA Blood Bank. No new transfusion
data has been entered since LR*5.2*408 (compliance date August 18,
2011) was installed to turn off VistA Blood Bank. The end
result is that the LRBLPCH option is obsolete and the change to
ICD codes is not relevant. The LRBLPCH option will be placed out
of order with the installation of this patch.
Verification: Any attempt to execute the option will return a
message that it is out of order.
installation in Production. The user validates the Blood Bank software
4. 112 VistA MR 111914 - Workload configuration and details are not
maintained in the development accounts which results in errors when
the workload process is triggered. Minor changes to the VistA
workload code prevents the workload process from proceeding when
there is no workload to process. Changes to the VBECRPCC routine
will prevent the error caused when there is no workload to process.
Verification: None
for its intended use prior to its acceptance and use for patient care.
There is also a VistA Blood Establishment Computer Software (VBECS)
2.0.0 server update that is also being released. Please refer
to the VistA Blood Establishment Computer Software (VBECS) 2.0.0
Release Notes for detailed information about corrections in that release.
BLOOD BANK CLEARANCE:
=====================
EFFECT ON BLOOD BANK FUNCTIONAL REQUIREMENTS: Patch VBEC*1*54 contains
changes to a package referenced in BBM TEAM REVIEW OF VISTA PATCHES.
This patch does not alter or modify any VistA Blood Bank software design
safeguards or safety critical elements functions.
RISK ANALYSIS: Changes made by patch VBEC*1*54 have no affect on Blood
Bank software functionality, therefore RISK is none.
ROUTINE:
========
VBECA1B1
VBECRPCB
- DATE INSTALLED AT THIS SITE: 2009-06-09 00:00:00
- INSTALLED BY: USER,SEVENTEEN
- DESCRIPTION OF ENHANCEMENTS:
VBEC*1*0 is being exported as part of the VBECS_BUNDLE_1.KID package
assigned as a Secondary Menu Option.
PROTOCOL:
=========
VBECS ADT-AO8 CLIENT - This protocol is used to deliver HL7 messages
from VistA to VBECS via the VBECSPTU logical link.
VBECS ADT-A08 ROUTER - This protocol is used to receive an HL7 message
from the VAFC ADT-A08 SERVER protocol and executes routing logic to
I. OVERVIEW
determine whether the message is to be forwarded to VBECS. VBECS
receives only messages that contain changes to various patient
demographic data.
VBECS ADT-AO8 SERVER - This event driver protocol is triggered by the
VBECS ADT-A40 CLIENT - This protocol is used to deliver the HL7
message from VistA to VBECS via the VBECSPTM logical link.
VBECS ADT-A40 SERVER - This event driver protocol is triggered by the
The VistA Blood Establishment Computer Software (VBECS) shall facilitate
VBECS OMG CLIENT - This is the subscriber protocol to the VBECS OMG
SERVER protocol that receives the HL7 message from VBECS providing
order updates to the original order message.
VBECS OMG SERVER - This protocol is triggered when an HL7 message from
VBECS is received by the HL7 package.
HL7 APPLICATION PARAMETER:
ongoing compliance with Food and Drug Administration (FDA) standards for
==========================
VBECS - This HL7 Application represents the VBECS side of the VBECS/CPRS
interface.
VBECS ADT - This HL7 Application represents the receiving application
of the Patient Update and Patient Merge router protocols.
VBECS TRIGGER - This HL7 Application represents the VBECS side of the
Patient Update and Patient Merge interfaces.
medical devices and enhance the Department of Veterans Affairs (VA)
HL LOGICAL LINK:
================
VBECS-OERR - Used to transmit HL7 messages from VBECS to CPRS.
VBECSPTM - Used to transmit HL7 messages from VistA to VBECS when a
patient merge event occurs.
VBECSPTU - Used to transmit HL7 messages from VistA to VBECS when a
patient update event occurs.
Veterans Health Administration's (VHA) ability to deliver quality
PARAMETER DEFINITION:
=====================
VBECS VISTALINK - Parameter definition used to identify all VBECS
Parameters.
PARAMETERS:
===========
LISTENER IP ADDRESS - Stores the value of the Blood Bank medical
device server where the VistALink listener is installed.
services to meet the needs of the user community. VBECS is considered an
LISTENER PORT NUMBER - Stores the value of the port number where Blood
Bank medical device VistALink listener is listening.
These Parameters are used by M APIs to build the XML messages used by
VistALink.
VBECS Blood Products
VBECS DSS Extract
VBECS Order Entry
VBECS Patient ABID
VBECS Patient ABO_RH
encapsulated medical device and therefore does not communicate directly
VBECS Patient Available Units
VBECS Patient Report
VBECS Patient TRRX
VBECS Patient Transfusion History
VBECS Update Workload Event
VBECS Workload
REMOTE PROCEDURE:
=================
VBECS ACCESSION AREA LOOKUP
with other VistA applications.
VBECS BLOOD BANK USER LOOKUP
VBECS DIVISION LOOKUP
VBECS DSS EXTRACT
VBECS HCPCS CODES LOOKUP
VBECS HOSPITAL LOCATION LOOKUP
VBECS LAB ACCESSION UID LOOKUP
VBECS LAB ORDER LOOKUP BY UID
VBECS LAB TEST RESULTS LOOKUP
VBECS LABORATORY TEST LOOKUP
VBECS MED PROFILE LOOKUP
VBECS PATIENT LOOKUP
VBECS PROVIDER LOOKUP
VBECS WORKLOAD CODES LOOKUP
GLOBALS - FILES:
===============
^VBEC(6002.01, - VBECS WORKLOAD CAPTURE File (#6002.01)
ICRs:
=====
release. The installation of this bundle will be controlled by phase
Two new namespaces are being introduced into the VistA enterprise with
The following ICRs were created to allow data transfer between the Blood
Bank medical device and the VBECS Application Interfacing Support
software.
4607, 4608, 4609, 4610, 4611, 4612, 4613, 4614, 4615, 4616, 4617,
4618, 4619, 4620, 4621, 4622, 4623, 4624, 4625, 4626, 4627, 4628, 4633
The following ICRs were created, or modified, to allow data transfer
between the VBECS Application Interfacing Support software and other
VistA applications.
1587, 1963, 2400, 2503, 2817, 3176, 3177, 3181, 3631, 3879, 4629,
the release of VBECS. The first, gov.va.med.vbecs, represents the Blood
4636, 4766, 4767, 4773, 4774, 4776, 4779,
ASSOCIATED REMEDY TICKETS
=========================
N/A
TEST SITES:
===========
HEARTLAND-EAST HCS
PHILADELPHIA, PA
Bank medical device software. The second, VBEC, represents the VBECS
SAN DIEGO, CA
SACC Exemptions:
================
XINDEX displays the following warning. The Standards And Conventions
Committee granted an exemption to allow the use of a star read on May 4th
2006.
VBECRL * * 114 Lines, 4099 Bytes, Checksum: B10917646
FOR READ VBECX#VBECREAD:VBECTO SET TOFLAG=$T DO:VBECFRST CHK
Application Interfacing Support software. The VBEC namespace, created in
DO:'VBECS
TOP QUIT:DONE
READ+6 I - Star or pound READ used.
Installation Sequence
======================
The files listed below represent the patches that will be part of the
controlled phased release. Follow the sequence listed below when your
phased installation occurs.
the VBEC 1.0 KIDS build, will be added to the Package file in VistA and
1. LR*5.2*335
2. LR*5.2*367
3. VBECS Bundle (consisting of VBEC*1*0 and LR*5.2*325)
4. VBEC*1.0*1
5. OR*3.0*212
Documentation Retrieval:
Documentation is available for the entire VBECS package on the
ANONYMOUS.SOFTWRE directory at one of the following Office of Information
is used to identify the M software and files that support interfacing
(OI) Field Offices. Sites may retrieve documentation in either ".PDF" or
"DOC" format in one of the following ways:
1. The preferred method is to FTP the files from :
Download.vista.domain.ext
2. Sites may also elect to retrieve documentation directly from a
specific server as follows:
Albany ftp.fo-albany.domain.ext
Hines ftp.fo-hines.domain.ext
other VistA applications with the Blood Bank medical device. This
Salt Lake City ftp.fo-slc.domain.ext
NOTE: The documentation files listed below will be listed in each of the
VBECS and LR patches that are part of the VBECS package and associate
patches, they only need to be downloaded once.
File Name Retrieval format: Binary
=========== ==========================
Blood Bank Pre-Implementation Data Validation, Mapping, and Conversion
ADPAC Guide.doc
software is not released as part of the Blood Bank medical device.
Blood Bank Pre-Implementation Data Validation, Mapping, and Conversion
ADPAC Guide.pdf
Blood Bank Pre-Implementation Data Validation, Mapping, and Conversion
Installation and User Guide.doc
Blood Bank Pre-Implementation Data Validation, Mapping, and Conversion
Installation and User Guide.pdf
Blood Bank Pre-Implementation Data Validation, Mapping, and Conversion
Technical Manual.doc
Blood Bank Pre-Implementation Data Validation, Mapping, and Conversion
Technical Manual.pdf
VBECS Data Conversion Recommended Validation Method.xls
VBECS Application Interfacing Support Software Installation and User
Configuration Guide.doc
VBECS Application Interfacing Support Software Installation and User
Configuration Guide.pdf
VBECS Implementation Process.xls
VistA Blood Establishment Computer Software (VBECS) 1.4.0.0 Installation
Guide.doc
VistA Blood Establishment Computer Software (VBECS) 1.4.0.0 Installation
Guide.pdf
II. FUNCTIONAL OVERVIEW
VistA Blood Establishment Computer Software (VBECS) 1.4.0.0 Technical
Manual-Security Guide.doc
VistA Blood Establishment Computer Software (VBECS) 1.4.0.0 Technical
Manual-Security Guide.pdf
VistA Blood Establishment Computer Software (VBECS) 1.4.0.0 User Guide.doc
VistA Blood Establishment Computer Software (VBECS) 1.4.0.0 User Guide.pdf
Known Defects and Anomalies.doc
Known Defects and Anomalies.pdf
INSTALLATION INSTRUCTIONS:
release. An Implementation Manager will be assigned to your site and
The reengineered Blood Bank system uses VistALink and Health Level Seven
==========================
Pre-Installation Items:
=======================
Environment Check:
------------------
Programmer access is required to install this patch. Prior to
installation, the installer must ensure the DUZ(0) node of the DUZ array
is set to the "@" symbol.
(HL7) messaging for data exchange with a client-server mode application
Users on the System:
--------------------
This patch may be installed with users on the system.
Software Installation Time:
---------------------------
The estimated installation time for this patch is less than
5 minutes during non-peak hours.
interfacing architecture through M Application Programmer Interfaces
Queuing:
---------
Note: Patch installation requires responses from the installer and
must not be queued.
Pre-requisites:
---------------
Patch installer must enter the collection sample types for new Lab
tests created during installation. Obtain sample types from the
Laboratory Information Manager
(APIs), VistA Remote Procedure Calls (RPCs), and HL7 interfaces released
Namespace:
----------
The namespace for the VBECS Application Interfacing Support package is:
Name: VBECS - Prefix: VBEC
Required Patches:
-----------------
Application Patch/Build
----------------------------- -----------
in the VBEC 1.0 KIDS build.
Laboratory Services LR*5.2*187
LR*5.2*288
LR*5.2*294
Toolkit XT*7.3*58
New File and Global Information:
--------------------------------
There is one new global, ^VBEC. The ^VBEC global contains the
following new file.
Journaling
File # File Name Global Root Recommended
------ ------------------------ ------------ -----------
6002.01 VBECS WORKLOAD CAPTURE ^VBEC(6002.01, YES
VBECS Configuration Checklists:
-------------------------------
a. Complete Appendix D: Configuration Checklist of the VistA Blood
Establishment Computer Software (VBECS) Installation Guide.
b. Complete Appendix B: Configuration Worksheet of the VBECS
Application Interfacing Support Software Installation and User
This software will provide a transparent database transition through the
Configuration Guide.
Installation Steps:
===================
The installation of VBECS and its related patches are being handled as a
controlled release. The implementation manager will contact you with the
location of the KIDS Host Files prior to your scheduled installation
date. The documentation files will be available for download in advance
of installation through the anonymous download site.
use of M APIs, RPCs, and HL7 interfaces. The APIs released in this build
1. Use the 'LOAD A DISTRIBUTION' option (#1) on the 'KIDS INSTALLATION'
menu, and enter: VBECS_BUNDLE_1.KID
2. From the 'Kernel Installation & Distribution System' menu, select
the Installation menu.
3. From this menu, you may now elect to use the following options (when
prompted for INSTALL NAME, enter VBECS BUNDLE 1.0)
will allow other VistA applications to continue the retrieval of Blood
a. Backup a Transport Global - This option will create a backup
message of any routines exported with the patch. It will NOT
backup any changes such as DDs or templates.
b. Compare Transport Global to Current System - This option will
allow you to view all changes that will be made when the patch
is installed. It compares all components of the patch
(routines, DDs, templates, etc.).
c. Verify Checksums in Transport Global - This option will allow you
Bank data stored in the Blood Bank system. The RPCs will allow the Blood
to ensure the integrity of the routines that are in the
transport global.
d. Print Transport Global - this option will allow you to view the
components of the KIDS build.
4. Use the Install Package(s) option and select package
VBECS_BUNDLE_1.KID. This will automatically install VBEC*1*0
and LR*5.2*325
will contact your POC for VBECS and will provide your site with the
Bank system to continue to retrieve data from other VistA applications.
5. When prompted "Enter the Coordinator for Mail Group 'VBECS INTERFACE
ADMIN':", please enter the name of the individual that will be
responsible for maintaining the new mail group. This mail group
receives notifications when an HL7 transmission, or a query through
the VBECS VistALink client, to the Blood Bank medical device has
failed. The users added to this group would be Lab/Blood Bank
supervisors and/or IRM staff responsible for managing the VBECS
package and interfaces.
6. When prompted 'Want KIDS to Rebuild Menu Trees Upon Completion of
The HL7 interfaces will allow the exchange of data between the Blood Bank
Install? NO//', respond Yes.
7. When prompted 'VBECS Server IP Address:', enter the Cluster
IP address from Appendix B: Configuration Worksheet, Hardware
Information, row 1.
8. When prompted 'VBECS VistALink Listener Service Port Number:',
enter the VistALink Listener Service port number from
Appendix B: Configuration Worksheet, Hardware Information, row 2
for installing in the TEST account, row 3 for installing in the
system and other VistA applications.
PRODUCTION account.
9. When prompted 'Want KIDS to INHIBIT LOGONs during the install?
No//', it is recommended you answer NO.
8. When prompted 'Want to DISABLE Scheduled Options, Menu Options,
and Protocols? No//', respond NO
11. When prompted by "Select COLLECTION SAMPLE for Lab Test
ABO/RH - LAB:," select the collection sample appropriate for the
ABO/Rh test.
12. When prompted by "Select COLLECTION SAMPLE for Lab Test ANTIBODY
SCREEN - LAB:," select the collection sample appropriate for the
Antibody Screen test.
13. When prompted by "Select COLLECTION SAMPLE for Lab Test DIRECT
ANTIGLOBULIN TEST - LAB:," select the collection sample appropriate
for the Direct Antiglobulin Test test.
III. TECHNICAL COMPONENTS
14. When prompted by "Select COLLECTION SAMPLE for Lab Test TRANSFUSION
REACTION WORKUP - LAB:," select the collection sample appropriate
for the Transfusion Reaction Workup test.
15. When prompted by "Select COLLECTION SAMPLE for Lab Test
TYPE & SCREEN - LAB:," select the collection sample appropriate for
the Type & Screen test.
16. The POST Installation routine VBECPOST will be deleted from
your system automatically after successful installation.
This section lists the components of the VBECS, and LAB SERVICES
installed in VistA by the VBEC BUNDLE 1.0 Multi Package KIDS build that
supports VBECS.
location of the KIDS Host Files prior to your scheduled installation date
MAIL GROUP:
===========
VBECS INTERFACE ADMIN - Receives alert mail messages when problems
arise with VBECS Application Interfacing. The users added to this group
would be Lab/Blood Bank supervisors and/or IRM responsible for managing
the VBECS package and interfaces.
ROUTINES:
=========
VBECA1
Installation Sequence. The VBECS BUNDLE is a host file that consists of
VBECA1A
VBECA1B
VBECA1B1
VBECA3
VBECA3A
VBECA3B
VBECA3C
VBECA4
VBECA5A
VBECA5B
both VBEC*1*0 and LR*5.2*325. Installation of the VBECS BUNDLE will
VBECA6
VBECA7
VBECA7A
VBECA7A1
VBECA7B
VBECENV
VBECHLRT
VBECLU
VBECLU0
VBECLU3
automatically install both VBEC*1*0 and LR*5.2*325
VBECPOST
VBECRL
VBECRPC
VBECRPC1
VBECRPCA
VBECRPCB
VBECRPCC
VBECRPCD
VBECRPCE
VBECRPCH
=====================
VBECRPCM
VBECRPCP
VBECRPCW
VBECVLC
OPTION:
=======
VBECS VISTALINK CONTEXT - (B)roker type option used by VistALink to
authenticate users. All Blood Bank users must have this option
-
- 2.0
- PATCH APPLICATION HISTORY:
-
-
- 0
- DATE APPLIED: 2016-11-18 17:14:50
- APPLIED BY: USER,FIFTYFOUR
-
- 1 SEQ #2
- DATE APPLIED: 2018-12-06 15:58:54
- APPLIED BY: USER,FIFTYFOUR
- DESCRIPTION:
This patch (VBEC*2*1) is being released in conjunction with the Vista
The VistA patch is released with a seven (7) day compliance date.
=======================================================================
Veterans Health Administration (VHA) Customer Documents:
VistA Blood Establishment Computer Software (VBECS) 2.3.0 Release
Notes.docx
VistA Blood Establishment Computer Software (VBECS) 2.3.0 Release
Notes.pdf
VistA Blood Establishment Computer Software (VBECS) 2.3.0 Technical
Manual-Security Guide.docx
VistA Blood Establishment Computer Software (VBECS) 2.3.0 Technical
Manual-Security Guide.pdf
VistA Blood Establishment Computer Software (VBECS) 2.3.0 User Guide.docx
VistA Blood Establishment Computer Software (VBECS) 2.3.0 User Guide.pdf
VistA Blood Establishment Computer Software (VBECS) 2.3.0 Admin User
Guide.docx
VistA Blood Establishment Computer Software (VBECS) 2.3.0 Admin User
Guide.pdf
VBECS Known Defects and Anomalies.docx
VBECS Known Defects and Anomalies.pdf
BLOOD BANK CLEARANCE
PATCH INSTALLATION:
===================
Pre/Post installation Overview:
===============================
Refer to the VistA Blood Establishment Computer Software (VBECS) 2.3.0
Release Notes document for pre and post installation information and
instructions.
====================
Pre-Installation Instructions:
==============================
Create a test with the following information prior to patch installation.
NAME: VBEC PATIENT REFLEX TEST TYPE: NEITHER
SUBSCRIPT: WORKLOAD HIGHEST URGENCY ALLOWED: ROUTINE
PRINT NAME: VBEC PATIENT REFLEX CREATION DATE: <Use current date>
Installation Instructions:
==========================
EFFECT ON BLOOD BANK FUNCTIONAL REQUIREMENTS: Patch VBEC*2*1 contains
This patch may be loaded with users on the system.
Installation will take less than 5 minutes.
1) Use the INSTALL/CHECK MESSAGE option on the PackMan menu to unload
the KIDS distribution included with this message.
2) From the Kernel Installation and Distribution System Menu,
select the Installation menu.
3) From this menu, you may elect to use the following options
(when prompted for the INSTALL NAME, enter VBEC*2*1).
a) Backup a Transport Global - this option will create a backup
changes to a package referenced in VHA OI SEPG SOP 192-023 Review of
message of any routines exported with the patch. It will NOT
backup any other changes such as DDs or templates.
b) Compare Transport Global to Current System - this option will
allow you to view all changes that will be made when the patch
is installed. It compares all components of the patch
(routines, DDs, templates, etc.).
c) Verify Checksums in Transport Global - this option will allow
you to ensure the integrity of the routines that are in the
transport global.
d) Print Transport Global - this option will allow you to view
VISTA Patches for Effects on VISTA Blood Bank Software. This patch does
the components of the KIDS build.
4) Use the Install Package(s) option and select the package
VBEC*2*1.
5) If prompted 'This Patch is for Version 2, you are running
Version 1 Want to continue installing this build? No//' respond
YES.
6) When prompted 'Want KIDS to INHIBIT LOGONs during the install?
NO//' respond NO.
7) When prompted 'Want to DISABLE Scheduled Options, Menu Options,
and Protocols? NO//' respond NO.
not alter or modify any VistA Blood Bank software design safeguards or
safety critical elements functions.
Blood Establishment Computer Software (VBECS) VBECS 2.3.0 server patch.
RISK ANALYSIS: Changes made by patch VBEC*2*1 have no adverse effect on
VistA Blood Bank software functionality, therefore RISK is none.
VALIDATION REQUIREMENTS:
========================
The VBECS 2.3.0 update and VBEC*2*1 require customer validation in the
local Test account prior to installation in Production to meet Food &
Drug Administration (FDA) requirements. The user validates the Blood Bank
software for its intended use prior to its acceptance and use for patient
care. The VBECS 2.3.0 Release Notes contain descriptions of the changes
made in this patch and includes validation scenarios.
It is imperative that the installation of VBEC*2*1 occur prior to the
installation of the VBECS 2.3.0 server patch. Coordinate the installation
with Pathology & Laboratory Medicine Service staff to allow adequate time
for impact analysis and testing the changes prior to installation in
Production.
Files & Fields Associated:
==========================
Installation of this patch will have no effect on sites who have not
N/A
FORMS ASSOCIATED:
=================
N/A
MAIL GROUPS ASSOCIATED:
=======================
N/A
installed VBECS.
OPTIONS ASSOCIATED:
===================
N/A
PROTOCOLS ASSOCIATED:
=====================
N/A
SECURITY KEYS ASSOCIATED:
=========================
N/A
TEMPLATES ASSOCIATED:
=====================
N/A
ADDITIONAL INFORMATION:
=======================
N/A
A full description of the VistA patch changes and implementation process
NEW SERVICE REQUESTS (NSRS):
============================
N/A
PATIENT SAFETY ISSUES (PSIS):
=============================
N/A
DEFECT TRACKING SYSTEM TICKET(S) & OVERVIEW:
============================================
are included in the VBECS 2.3.0 Release Notes.
I5868220FY15
I7744342FY16
I6114955FY16
I7083226FY16
I17762673FY18
TEST SITES:
===========
MILWAUKEE, WI
PHILADELPHIA, PA
SAN FRANCISCO, CA
HINES, IL
IOWA CITY, IA
DOCUMENTATION RETRIEVAL INSTRUCTIONS:
=====================================
Documentation describing the new functionality introduced by this patch
is available. Documentation can be found on the VA Software Documentation
Library at: https://www.domain.ext/vdl/application.asp?appid=182
-
- 3 SEQ #3
- DATE APPLIED: 2019-07-08 16:36:29
- APPLIED BY: USER,SIXTYFIVE
- DESCRIPTION:
This patch (VBEC*2*3) serves to alert VA facilities using the Vista Blood
Installation Instructions:
==========================
This patch may be loaded with users on the system.
Installation will take less than 5 minutes.
1) Use the INSTALL/CHECK MESSAGE option on the PackMan menu to unload
the KIDS distribution included with this message.
2) From the Kernel Installation and Distribution System Menu,
select the Installation menu.
3) From this menu, you may elect to use the following options
A full description of patch changes and implementation process are
(when prompted for the INSTALL NAME, enter VBEC*2*3).
a) Backup a Transport Global - this option will create a backup
message of any routines exported with the patch. It will NOT
backup any other changes such as DDs or templates.
b) Compare Transport Global to Current System - this option will
allow you to view all changes that will be made when the patch
is installed. It compares all components of the patch
(routines, DDs, templates, etc.).
c) Verify Checksums in Transport Global - this option will allow
you to ensure the integrity of the routines that are in the
included in the VBECS 2.3.1 Release Notes.
transport global.
d) Print Transport Global - this option will allow you to view
the components of the KIDS build.
4) Use the Install Package(s) option and select the package
VBEC*2*3.
5) When prompted 'Want KIDS to INHIBIT LOGONs during the install?
NO//' respond NO
6) When prompted 'Want to DISABLE Scheduled Options, Menu Options,
and Protocols? NO//' respond NO.
Back-Out Plan
-------------
During installation, if the option to back up routines was run as
directed, "Backup a Transport Global", then routines will have the
ability to be restored from the "backup" MailMan message that was
generated. However, the KIDS installation process does not perform a
restore of other VistA components, such as data dictionary,
cross-reference, and template changes, etc.
Prior to attempting a back-out of the software, submit a YOUR IT
The patch is released with a sixty (60) day compliance date.
Services
ticket with the Enterprise Service Desk (ESD) for assistance with the
procedure.
For VistA patches, the general strategy for back-out is to repair the
code with another follow-on patch. Depending on each individual patch,
sites will be given a procedure detailing how to complete the back-out.
If any issue(s) with the software are discovered after it is nationally
released the development team will research the issue and provide
guidance for any immediate, possible work around.
Long-term solutions will be one of the following: installation of a
follow-up patch to correct the defect, a follow-up patch to remove the
defective updates, or a procedure detailing how the software can be
safely backed out of the production system.
BLOOD BANK CLEARANCE
====================
EFFECT ON BLOOD BANK FUNCTIONAL REQUIREMENTS: Patch VBEC*2*3 contains
changes to a package referenced in VHA OI SEPG SOP 192-023 Review of
Establishment Computer Software (VBECS) that VBECS 2.3.1 server patch has
VISTA Patches for Effects on VISTA Blood Bank Software. This patch does
not alter or modify any VistA Blood Bank software design safeguards or
safety critical elements functions.
RISK ANALYSIS: Changes made by patch VBEC*2*3 have no adverse effect on
VistA Blood Bank software functionality, therefore RISK is none.
VALIDATION REQUIREMENTS:
========================
The VBECS 2.3.1 server patch requires customer validation in the local
been released for installation.
Test account prior to installation in Production to meet Food & Drug
Administration (FDA) requirements. The user validates the Blood Bank
software for its intended use prior to its acceptance and use for patient
care. The VBECS 2.3.1 Release Notes contain descriptions of the changes
made in this patch and includes validation scenarios.
It is imperative that the AITC coordinate the installation of the VBECS
2.3.1 server patch with Pathology & Laboratory Medicine Service staff to
allow adequate time for impact analysis and testing the changes prior to
installation in Production.
PRIORITY:
=========
Mandatory
Category:
=========
Routine
Informational
Sites who have not installed VBECS have no action to take with this patch.
COMPONENTS:
===========
Routines:
VBEC2P3
VBECHLRT
DEFECT TRACKING SYSTEM TICKET(S) & OVERVIEW:
============================================
INC1232882 - update to the VBECS Blood Product Code file
TEST SITES:
===========
Iowa City
Milwaukee
San Diego
DOCUMENTATION RETRIEVAL INSTRUCTIONS:
=====================================
Documentation describing the new functionality introduced by this patch
is available. (.docx and .pdf files)
VBECS 2.3.1 will be installed by System Administrators at the Austin
Veterans Health Administration (VHA) Customer Documents:
VistA Blood Establishment Computer Software (VBECS) 2.3.1 Administrator
User Guide
VistA Blood Establishment Computer Software (VBECS) 2.3.1 Release
Notes.docx
VistA Blood Establishment Computer Software (VBECS) 2.3.1 Technical
Manual-Security Guide.docx
VistA Blood Establishment Computer Software (VBECS) 2.3.1 User Guide.docx
VBECS 2.3.1 Known Defects and Anomalies.docx
Information Technology Center (AITC). Please refer to VBECS 2.3.1 Release
Documentation can be found on the VA Software Documentation Library at:
http://www4.domain.ext/vdl/
PATCH INSTALLATION:
===================
Pre/Post installation Overview:
===============================
Notes for details.
Refer to the VistA Blood Establishment Computer Software (VBECS) 2.3.1
Release
Notes document for pre and post installation information and instructions.
Pre-Installation Instructions:
==============================
Refer to the VistA Blood Establishment Computer Software (VBECS) 2.3.1
Release
Notes document for pre and post installation information and instructions.
-
- 8 SEQ #8
- DATE APPLIED: 2020-09-23 10:47:04
- APPLIED BY: USER,SIXTYFIVE
- DESCRIPTION:
This patch installs updates to the Computerized Patient Record System
New Service Requests (NSRs):
----------------------------
20170604: CPRS Blood Bank Report
Work Items:
-----------
214353 CPRS CQ# 19382: Need to update the VAIS and DBIA 4623
434646 VistA - Fixing canned comments on tests sent to VistA
822792 NSR 20170604: CPRS Blood Bank Report
906324 Transmit the ABO/Rh of Transfused Units to CPRS for Display in
A full description of patch changes, implementation process, and
the CPRS Blood Bank Report
939717 Update VBECS VistA MailMan server to report VBECS VistA version
2 patches
970431 Replace Expiration Date with Issued Date/Time on the CPRS Blood
Bank Report in the Available/Issued Units section
1093252 Remove reaction strengths for DAT tests from CPRS blood bank
report.
1186563 CPRS Blood Bank Report does not differentiate tests completed
on the same date/time
validation scenarios are included in the VBECS 2.3.2 Rev F Release Notes.
1230175 Add reference range for ABS and DAT to CPRS Blood Bank Report
1247284 Cancelled orders remain in Component Requests section CRPS
Blood Bank Report
Patient Safety Issues (PSIs):
-----------------------------
N/A
Defect Tracking System Ticket(s) & Overview:
--------------------------------------------
N/A
Test Sites:
-----------
TBD
Software and Documentation Retrieval Instructions:
The Test and Production accounts will be installed separately. There is
Documentation describing the new functionality introduced by this patch
is available on the VA Software Documentation Library at:
http://www.domain.ext/vdl/application.asp?appid=182
Refer to the VBECS 2.3.2 Rev F Release Notes for a list of the user
documentation associated with this revision letter patch.
Additional VBECS information can be accessed on the VBECS SharePoint site
at: https://dvagov.sharepoint.com/sites/oitepmovbecs
no downtime associated with this patch installation. Refer to the VBECS
Patch Installation:
-------------------
Pre-Installation Instructions:
This patch may be installed with users on the system although it is
recommended that it be installed during non-peak hours to minimize
potential disruption to users. This patch should take less than 5
2.3.2 Rev F Release Notes for further installation details.
minutes to install.
No options need to be disabled during installation.
Installation Instructions:
1. Choose the PackMan message containing this build. Then select the
INSTALL/CHECK MESSAGE PackMan option to load the build.
2. From the Kernel Installation and Distribution System Menu, select the
Installation Menu. From this menu,
A. Select the Verify Checksums in Transport Global option to confirm
the integrity of the routines that are in the transport global.
When prompted for the INSTALL NAME enter the patch name VBEC*2.0*8.
B. Select the Backup a Transport Global option to create a backup
message of any routines exported with this patch. It will not
backup any other changes such as DDs or templates.
C. You may also elect to use the following options:
i. Print Transport Global - This option will allow you to view
the components of the KIDS build.
ii. Compare Transport Global to Current System - This option
will allow you to view all changes that will be made when
this patch is installed. It compares all of the components
of this patch, such as routines, DDs, templates, etc.
D. Select the Install Package(s) option and choose the patch to
install.
i. If prompted 'Want KIDS to Rebuild Menu Trees Upon Completion
of Install? NO//', answer No
ii. When prompted 'Want KIDS to INHIBIT LOGONs during the install?
NO//', answer No
iii. When prompted 'Want to DISABLE Scheduled Options, Menu
Options, and Protocols? NO//', answer No
(CPRS) BLOOD BANK REPORT.
Patch Components:
Post-Installation Instructions:
N/A
Back-Out/Roll Back Plan:
------------------------
This patch consists of five routines. During the VistA Installation
Procedure the installer should back up the modified routines by the
use of the 'Backup a Transport Global' action (step 2B in
the Installations Instructions).
-----------------
If rollback/backout is required, the installer can restore the routines
using the MailMan message that were saved prior to installing the
patch.
If assistance is needed to rollback/backout the patch, please log a
Service Now ticket.
Files & Fields Associated:
File Name (Number) Field Name (Number) New/Modified/Deleted
------------------ ------------------- --------------------
N/A
Forms Associated:
Form Name File Number New/Modified/Deleted
--------- ----------- --------------------
N/A
Mail Groups Associated:
This patch also serves to alert VA facilities using the Vista Blood
Mail Group Name New/Modified/Deleted
--------------- --------------------
N/A
Options Associated:
Option Name Type New/Modified/Deleted
----------- ---- --------------------
N/A
Establishment Computer Software (VBECS) that VBECS 2.3.2 Rev F server
Protocols Associated:
Protocol Name New/Modified/Deleted
------------- --------------------
N/A
Security Keys Associated:
patch has been released for installation. VBECS 2.3.2 Rev F will be
Security Key Name
-----------------
N/A
Templates Associated:
Template Name Type File Name (Number) New/Modified/Deleted
------------- ---- ------------------ --------------------
N/A
installed by System Administrators at the Austin Information Technology
Remote Procedures Associated:
Remote Procedure Name New/Modified/Deleted
--------------------- --------------------
N/A
Parameter Definitions Associated:
Center (AITC).
Parameter Name New/Modified/Deleted
-------------- --------------------
N/A
Additional Information:
-----------------------
Blood Bank Team Coordination:
-----------------------------
EFFECT ON BLOOD BANK FUNCTIONAL REQUIREMENTS: Patch VBEC*2*8 contains
changes to a package referenced in VHA OI SEPG SOP 192-023 Review of
VISTA Patches for Effects on VISTA Blood Bank Software. This patch does
not alter or modify any VistA Blood Bank software design safeguards or
safety critical elements functions.
RISK ANALYSIS: Changes made by patch VBEC*2*8 have no effect on VistA
Blood Bank software functionality, therefore RISK is none.
|