LA*5.2*47 (2343)    BUILD (9.6)

Name Value
NAME LA*5.2*47
DATE DISTRIBUTED 1999-06-22 00:00:00
PACKAGE FILE LINK AUTOMATED LAB INSTRUMENTS
REQUIRED BUILD
  • LA*5.2*27
    ACTION:   Don't install, leave global
TYPE SINGLE PACKAGE
ALPHA/BETA TESTING NO
DESCRIPTION OF ENHANCEMENTS
Patch LA*5.2*47 VISTA BLOOD BANK SOFTWARE V5.2 
All changes have been reviewed by the VISTA Blood Bank Developer and found
 
This patch is compatible with OERR 2.5 and both versions of CPRS ,GUI and
List Manager.
 
         1. Use the 'INSTALL/CHECK MESSAGE' option on the PackMan 
         menu. This option will load the KIDS package onto your system.
         2. Review your mapped set.  If the routines are mapped,
         they should be removed from the mapped set at this time.
         3. The patch has now been loaded into a Transport global 
         on your system. You now need to use KIDS to install the 
to have no impact on the VISTA BLOOD BANK SOFTWARE version 5.2 control
         Transport global.
         
         On the KIDS menu, under the 'Installation' menu, use the
         following options:
                Print Transport Global
                Compare Transport Global to Current System
                Verify Checksums in Transport Global
                Backup a Transport Global
         4. Users may remain on the system, but installation 
            should be done during off peak hours and when the Laboratory 
functions.
            computer users are idle.
         5. No options need to be placed out of service.
         6. Installation time is less than 2 minutes during off 
            peak hours, and less than 5 minutes during peak hours
            which is NOT RECOMMENDED.
         7. Installation of this patch does not require any additional 
            memory space.
         8. From the 'Installation Menu' of the KIDS menu, run the 
            option 'Install Package(s)'. Select the package 
            'LA*5.2*47' and proceed with the install.
 
         9. If any routines were unmapped as part of step 2, they 
            should be returned to the mapped set once the 
            installation has run to completion.
 
======================
Test Sites:
 
Long Beach, CA
Milwaukee, WI
Loma Linda, CA
RISK ANALYSIS: Changes made by patch LA*5.2*47 have no effect on Blood
North Chicago, IL
West Palm Beach, FL
=====================
 
DD Changes:
None
=====================
 
Routine Listing:
The second line of the routine now looks like:
Bank software functionality, therefore RISK is none.
<TAB>  ;;5.2;AUTOMATED LAB INSTRUMENTS;**[Patch List]**;Sep 27, 1994
 
Routines:        Before       After           Patch
                 Check        Check           List
LA47             N/A          2222265         47
LAGEN           8395369       9445120      1,17,22,27,47
 
===================
 
EFFECT ON BLOOD BANK FUNCTIONAL REQUIREMENTS: Patch LA*5.2*47 does not
alter or modify any software design safeguards or safety critical element
functions.
DEVICE PRODUCT LABELING STATEMENT
 
POTENTIAL IMPACT ON SITES: This patch contains no changes to files and
routines identified in Veterans Health Administration (VHA) Directive
97-033. The changes that are made have no effect to Blood Bank
functionality or medical device control functions. There is no adverse
potential to sites.
 
VALIDATION REQUIREMENTS BY OPTION: There are no required validation
scenarios to be completed by sites after installing this patch.
 
 
========================================
 
Patch Description: 
This is the companion patch for LR*5.2*221. Full description of ALL
enhancements are given in LR*5.2*221.  
  
This patch support the ability to purge Automated Instrument data based on
 
date range or inactivity range. This enhancement is to support Laboratory 
Electronic Data Interchange (LEDI) sites ability to purge automated
May 10, 1999
instrument data based on user's supplied parameters.  
 
The functionality of this patch is coupled with the features and function
of patch LR*5.2*221. LA*5.2*47 is required for LR*5.2*221 installation.
The functionality of the patch is expressed after patch LR*5.2*221 has
been installed.
 
ONLY THE ROUTINE 'LAGEN' IS CONTAINED IN THIS PATCH. All other LR*
associated name spaced routines and options are contained in LR*5.2*221.
The following options are transported and installed by LR*5.2*221.
 
 
The 'Clear instrument/worklist data' [LRINSTCLR] option has been enhanced.
The changes to this option implements selective clearing of instrument
data from the ^LAH global. When entries are made in the ^LAH global to
store instrument data pending verification, the date/time stamp of
creation and result updating is now recorded. This date will be used to
selectively remove data from the ^LAH global based on the date original
result was received or last updated.
    If during the clearing process an entry in ^LAH global is found with
no date/time in the creation/update field, the current date/time is
VISTA Laboratory Package patch LA*5.2*47 contains no changes to software
entered into the entry. This entry is then eligible for clearing the next
time the option is ran.
 
 
 The 'Clear instrument/worklist data' option will allow clearing by either
of the following ways. Data received before the selected date (optional
time) is purged. If you enter a date only then data received before that
date is cleared. If you enter a date/time then data received before that
date/time is cleared.
 
controlled by VHA DIRECTIVE 97-033, titled VISTA BLOOD BANK SOFTWARE
 Example:
If you enter Sept 4, 1998 then data received through Sept 3, 1998 is
cleared. If you enter Sept 4, 1998 @1200 then data through Sept 4, 1998 is
cleared.
 
 The following routines support purge enhancement:
   LAGEN [LA*5.2*47]- Changes were made to set date/time of entry creation
and last update. Last update can be different than creation date if data
is retransmitted (overlay data = yes) or additional results received.
 
VERSION 5.2.
   LRLLS [LR*5.2*221]- Clear instrument data option that does actual
clearing based on user's parameters. User can purge by date/time or
blanket purge when using Clear instrument/worklist data [LRINSTCLR]
option.
 
   LRVR1 [LR*5.2*221]-  Verifying routine with changes to setup date/time
information when manual data entry is used during Enter/Verify Automated
Instrument [LRVR] option.
 
   LRVRW [LR*5.2*221]-  Verifying routine with changes to setup date/time
 
information when load/work list data entry is used during the Enter/verify
data (Work list) [LRVRW] option.
 
 
 
Installation Instructions:
==========================
 
Required Patch Installation List:
LA*5.2*27
TRACK PACKAGE NATIONALLY YES
BUILD COMPONENTS
  • ENTRIES:
    • LAGEN
      ACTION:   SEND TO SITE
      CHECKSUM:   B21626847
ENVIRONMENT CHECK ROUTINE LA47