VAQ*1.5*33 (3937)    BUILD (9.6)

Name Value
NAME VAQ*1.5*33
DATE DISTRIBUTED 2001-10-29 00:00:00
PACKAGE FILE LINK PATIENT DATA EXCHANGE
TYPE SINGLE PACKAGE
DESCRIPTION OF ENHANCEMENTS
Patch VAQ*1.5*33
group G.VAQ PDX ERRORS to inform them of this.

NOIS WBP-0596-21007
Test Site: Wilkes Barre, PA

This patch ensures that incoming PDX messages are deleted from the server
basket, whether they processed successfully or errored out.

NOTE: This patch should be installed during off hours, when user activity
is at a minimum.  It has no patch pre-requisites.
 
==========================================================================
 
ROUTINES:
The second line of the routine now looks like:
       ;;1.5;PATIENT DATA EXCHANGE;**[patch list]**;NOV 17, 1993
 
             Before        After
Name       Checksum     Checksum     Patch List
-----------------------------------------------------------------
VAQADM2     2534049      3075526     33
NOIS SBY-0801-31431, FAV-1001-70165, COS-1001-40729, MAR-1001-20783
* Checksums produced by CHECK^XTSUMBLD
 
This patch introduces no new routines.
==========================================================================
 
INSTALLATION:
NOTE: This patch should be installed during off hours, when user activity
is at a minimum.  It has no patch pre-requisites.
1.  Users may be on the system during installation of this patch.
2.  DSM Sites: If any of these routines is mapped, disable mapping for the
Test Site: Salisbury, NC; Fayetteville, AR; Columbus, OH
    affected routine(s).  
3.  On the PackMan menu, use the 'INSTALL/CHECK MESSAGE' option.
    This loads the patch into a Transport Global on your system.  
4.  You do not need to stop TaskMan or the background filer.
    Users may be on the system.
5.  On the KIDS:Installation menu, use the following options to install
    the Transport Global.
       Verify Checksums in Transport Global
       Print Transport Global
       Compare Transport Global to Current System

       Backup a Transport Global
       Install Package(s)
 Select INSTALL NAME:   VAQ*1.5*33   Loaded from Distribution <date/time>
                        ==========
 Install Questions:
 Want KIDS to INHIBIT LOGONs during the install? YES// NO
                                                       ==
 Want to DISABLE Scheduled Options, Menu Options, and Protocols? YES// NO
                                                                       ==
 Enter the Device you want to print the Install messages.
This patch checks PDX requests from remote sites to ensure that the remote
 You can queue the install by enter a 'Q' at the device prompt.
 Enter a '^' to abort the install.
 
 DEVICE: HOME// <It's up to you.  You may queue it if you wish.>
                ------------------------------------------------
6.  DSM Sites: After patch has installed, rebuild your map set, if
    necessary.
==========================================================================
site is not flagged as Closed in the Domain file.  If the Domain file shows
that the site is closed, then the request is ignored, the message is
deleted from the server basket, and a message is sent to the members of the
TRACK PACKAGE NATIONALLY YES
BUILD COMPONENTS
  • ENTRIES:
    • VAQADM2
      ACTION:   SEND TO SITE
      CHECKSUM:   B8868084