OR*3.0*268 (8081)    BUILD (9.6)

Name Value
NAME OR*3.0*268
DATE DISTRIBUTED 2008-07-08 00:00:00
PACKAGE FILE LINK ORDER ENTRY/RESULTS REPORTING
REQUIRED BUILD
  • RA*5.0*93
    ACTION:   Don't install, leave global
TYPE SINGLE PACKAGE
ALPHA/BETA TESTING NO
DESCRIPTION OF ENHANCEMENTS
A site reported a patient safety issue with the alert information 
 
In the interim, the alert text is being modified to alleviate some of the 
confusion. In addition, some documentation updates are being made to 
remind sites to enable both of the alerts to ensure the provider gets all 
the appropriate information.
 
The NAME field (.01) and the MESSAGE TEXT field (.03) of the OE/RR 
NOTIFICATIONS file (#100.9) are being modified for alerts 22 and 25 
(internal entry numbers for the two alerts). Alert 22 is being changed 
from IMAGING RESULTS to IMAGING RESULTS, NON CRITICAL. Alert 25 is being 
displayed when imaging results, either abnormal or not, are completed. 
changed from ABNORMAL IMAGING RESULTS to ABNL IMAGING RESLT, NEED ATTN.
 
The change is being made using a post-installation routine. The person 
installing the patch will receive a MailMan message with a subject of 
'OE/RR NOTIFICATIONS ALERT NAME UPDATES' when the update is complete.
 
This patch requires a change in the Radiology/Nuclear Medicine V. 5.0 
package. The documentation changes to update the notification name will 
be included in a separate documentation release.
 
The problem stems from the fact that the alerts can be disabled and, if 
Please note: the post-install routine, ORY268, will be removed in a 
future patch.
 
Associated Remedy:
==================
1. HD0000000132027 Imaging Results versus Abnormal imaging results
 
Associated NSR(s):
==================
N/A
so, due to the text of the alert, the provider may miss some critical 
 
Test Sites:
===========
TBA
 
Overview:
=========
 
1. HD0000000132027 Imaging Results versus Abnormal imaging results
 
information.
   Problem:
   =========
   The Radiology Package currently always sends the following alert 
   notifications to OERR/CPRS, conditioned on the type of result (normal, 
   abnormal, amended - normal or abnormal)
      22 - IMAGING RESULTS (contains normal results)
      25 - ABNORMAL IMAGING RESULTS (contains abnormal results)
      53 - IMAGING RESULTS AMENDED (contains both normal and abnormal)
   Based on the parameter settings, some of these alerts may not display. 
   Due to the text of the alert subject, this may be misleading for the 
 
   provider.
 
   Solution:
   =========
   The 'imaging results' notification may refer to both normal and 
   abnormal results. The abnormal results are non-critical. The agreement 
   between the Computerized Patient Record System (CPRS) Clinical
   Workgroup and the Radiology subject matter expert is to modify the
   text of alerts 22 and 25 to reduce the confusion. Alert 22 will    
   become 'IMAGING RESULTS NON CRITICAL'. Alert 25 will become 'ABNL
The final solution is considered an enhancement and the Radiology subject 
   IMAGING RESLT, NEED ATTN'.
matter expert will be working with the patient safety office to formulate 
a new service request to outline the desired behavior.
TRACK PACKAGE NATIONALLY YES
SEQ# 275
BUILD COMPONENTS
POST-INSTALL ROUTINE ORY268
DELETE POST-INIT ROUTINE No