Print Page as PDF
Invalid MPI/PD exception messages sent to FORUM ICR (3244)

Invalid MPI/PD exception messages sent to FORUM    ICR (3244)

Name Value
NUMBER 3244
IA # 3244
FILE NUMBER 773
GLOBAL ROOT HLMA(D0,
DATE CREATED 2000/11/06
CUSTODIAL PACKAGE HEALTH LEVEL SEVEN
CUSTODIAL ISC San Francisco
USAGE Controlled Subscription
TYPE File
DBIC APPROVAL STATUS APPROVED
NAME Invalid MPI/PD exception messages sent to FORUM
GENERAL DESCRIPTION
Exception messages are being sent to the MPI/PD team
under the wrong circumstances.  Non-MPI/PD applications trigger exception
messages under inappropriate conditions because of issues in the execution of
the VistA Health Level Seven (HL7) software.  This IA will eliminate the
possibility of non-MPI/PD applications generating exception messages.
GLOBAL REFERENCE
GLOBAL REFERENCE FIELD NUMBER GLOBAL DESCRIPTION
HLMA('C',
FIELD NUMBER ACCESS FIELD NAME
2 Direct Global Read & w/Fileman MESSAGE ID
MESSAGE ID x-ref
HLMA(D0,
FIELD NUMBER ACCESS FIELD DESCRIPTION FIELD NAME LOCATION
13 Read w/Fileman
Indicates the application sending the message.
SENDING APPLICATION 0;11
14 Read w/Fileman
Indicates the application receiving this message.
RECEIVING APPLICATION 0;12
HLMA(D0,'MSH',D1,
FIELD NUMBER ACCESS FIELD DESCRIPTION FIELD NAME LOCATION
200 Read w/Fileman
This field, a word processing data type, is used to store
the "MSH" segment when the TCP/IP Lower Layer Protocol is used.
MSH 0;1
The data for this field, MSH, is located on the "MSH"
data node.
STATUS Active
KEYWORDS
  • invalid exception
  • MPI/PD exception messages
DURATION Till Otherwise Agreed
ID HLMA(D0,
SUBSCRIBING PACKAGE
SUBSCRIBING PACKAGE ISC SUBSCRIBING DETAILS
CLINICAL INFO RESOURCE NETWORK Birmingham
MASTER PATIENT INDEX
E CLAIMS MGMT ENGINE
CLINICAL PROCEDURES
added 3/22/10
RADIOLOGY/NUCLEAR MEDICINE
Added 10/31/24 effective with RA*5*220, Radiology is
doing exception handling and needs to look up the radiology HL7 Message ID
using FM in order to do a status check.