GENERAL DESCRIPTION
This RPC is used to validate the data scanned in at the
scan patient wristband prompt of the mnOpenPatient component.  The value
passed in is either the full SSN scanned in from the patient wristband -or-
the 1U4N syntax of the patient lookup.  In either case the call must return
only one patient from the lookup.  If the 1U4N syntax is used and multiple
patients are found the call returns an error.  If only one patient is found
the RESULTS array is loaded with the patient data and passed back to the
client for verification.