AUTOMATED SUPPLY STATION PROCESSING QUEUE FILE ACCESS
GENERAL DESCRIPTION
ABOVE PAR requests permission to check the AUTOMATED
SUPPLY STATION PROCESSING QUEUE (#447.1) file's STATION NUMBER (#1) and
SECONDARY INVENTORY POINT (#2) fields.
GLOBAL REFERENCE
GLOBAL REFERENCE
FIELD NUMBER
GLOBAL DESCRIPTION
PRCP(447.1,D0,0)
FIELD NUMBER
ACCESS
FIELD NAME
LOCATION
1
Read w/Fileman
STATION NUMBER
0;2
2
Read w/Fileman
SECONDARY INVENTORY POINT
0;3
PRCP(447.1,'C'
"C" cross reference - used to check OUTSTANDING
TRANSACTIONS BY AFFECTED INVENTORY POINT to determine if an Alert record has
been produced