Print Page as PDF
CP DICOM INTEROPERABILITY BUILD HL7 MESSAGE ICR (6932)

CP DICOM INTEROPERABILITY BUILD HL7 MESSAGE    ICR (6932)

Name Value
NUMBER 6932
IA # 6932
DATE CREATED 2018/06/15
CUSTODIAL PACKAGE IMAGING
USAGE Private
TYPE Routine
DBIC APPROVAL STATUS APPROVED
ROUTINE MAGDHOWP
NAME CP DICOM INTEROPERABILITY BUILD HL7 MESSAGE
GENERAL DESCRIPTION
This API builds the VistA Imaging procedure HL7 ORM
(order) message using the VistA Imaging formatted accession number.  The API
may conditionally return the HL7 ORM message body for Clinical Procedures'
use.
STATUS Active
KEYWORDS
  • MAG*3.0*208
  • MD*1.0*60
  • IMAGING
DURATION Till Otherwise Agreed
ID MAGDHOWP
COMPONENT/ENTRY POINT
COMPONENT/ENTRY POINT VARIABLES
CLINPROC
VARIABLES TYPE VARIABLES DESCRIPTION
FILE702P Input
This is the pointer to the clinical procedure record
in the CP TRANSACTION (#702) file.
ORDERFLAG Input
This variable indicates if the enhanced HL7 order
message is new or canceled.
SUBSCRIBING PACKAGE CLINICAL PROCEDURES