Print Page as PDF
VS GUI access to DGSEC4 routine ICR (7036)

VS GUI access to DGSEC4 routine    ICR (7036)

Name Value
NUMBER 7036
IA # 7036
DATE CREATED 2019/03/12
CUSTODIAL PACKAGE REGISTRATION
USAGE Private
TYPE Routine
DBIC APPROVAL STATUS APPROVED
ROUTINE DGSEC4
NAME VS GUI access to DGSEC4 routine
GENERAL DESCRIPTION

************************************************************************
*                                                                      *
*  This is a temporary ICR for the production VistA Scheduling (VS)    * *
GUI software.                                                       * *  The
need for this ICR was identified from the VS Sustainment Team   * *  reviewing
the VistA Scheduling Enhancement (VSE) software that was  * *  released
nationally without approved ICRs.  This temporary ICR      * *  represents the
situation, where the Custodian package experts       * *  requested changes to
the production software to use approved        * *  APIs, which requires a
future VS patch. This temporary ICR will     * *  expire when the production
code is modified to the use approved     * *  APIs
*
*                                                                      *
************************************************************************
STATUS Active
DURATION Till Otherwise Agreed
ID DGSEC4
COMPONENT/ENTRY POINT
COMPONENT/ENTRY POINT COMPONENT DESCRIPTION VARIABLES
OWNREC
VARIABLES TYPE VARIABLES DESCRIPTION
DFN Input
Patient file pointer.
DUZ Input
Scheduler's DUZ
DGMSG Input
Flag that tells the code to return a message.
DGREC Output
Array with the results.
SENS
Subroutine that returns sensitive information flags
about a patient.
VARIABLES TYPE VARIABLES DESCRIPTION
DFN Input
Patient pointer
DUZ Input
Scheduler's DUZ
DGSENS Output
Array containing sensitive information flags about
the patient.
SUBSCRIBING PACKAGE
SUBSCRIBING PACKAGE SUBSCRIBING DETAILS
SCHEDULING
VS GUI uses DGSEC4 to determine if the scheduler is
attempting to access his/her own record or if the record is for a sensitive
patient.  The GUI prevents access to the scheduler's own record and displays
appropriate warnings for sensitive patients.
DATE ACTIVATED 2019/05/21