+---------------------------------------------------------------+ | | | Property of the US Government. | | No permission to copy or redistribute this software is given. | | Use of unreleased versions of this software requires the user | | to execute a written test agreement with the VistA Imaging | | Development Office of the Department of Veterans Affairs, | | telephone (301) 734-0100. | | | | The Food and Drug Administration classifies this software as | | a medical device. As such, it may not be changed in any way. | | Modifications to this software may result in an adulterated | | medical device under 21CFR820, the use of which is considered | | to be a violation of US Federal Statutes. | +---------------------------------------------------------------+ This file contains MAG work item service type, mapped with Modality and Procedure.
INPUT TRANSFORM: K:$L(X)>128!($L(X)<1)!'(X'?1P.E) X
MAXIMUM LENGTH: 128
LAST EDITED: JUN 21, 2024
HELP-PROMPT: Enter the image modality and procedure with "|" in between, the answer must be more than 1 character in length. I.e.: "CR|MAGNETIC IMAGE,BRAIN"
DESCRIPTION:
This is the Modality and Procedure of Import image.
HELP-PROMPT: Enter the Service of import image, associated with Modality and Procedure. Answer must be 1-3 characters in length, For example: RAD for Radiology; CON for Consult; LAB for Laboratory.
DESCRIPTION:
This is the Service of import image, that is associated with Modality and Procedure.
CROSS-REFERENCE: 2006.9423^S
1)= S ^MAGV(2006.9423,"S",$E(X,1,30),DA)=""
2)= K ^MAGV(2006.9423,"S",$E(X,1,30),DA)
Service to associate with Modality | Procedure of Importer image|