- MPIFA24B ;BP/CMC-BUILD A24 ADD ME MSGS ; 5/4/20 10:59am
- ;;1.0;MASTER PATIENT INDEX VISTA;**22,28,31,25,43,44,51,61,68,75**;30 Apr 99;Build 1
- ;
- ; Integration Agreements Utilized:
- ; START, EXC, STOP^RGHLLOG - #2796
- ; BLDEVN, BLDPD1, BLDPID^VAFCQRY - #3630
- ;
- A24(DFN,PID2,NOA31) ;BUILD AND SEND A24 **43 added PID2 as a parameter - not required.
- ; if PID2 is defined it will contain the previous ICN data, passed by reference
- ; **51 ADDED NOA31 as a parameter to stop the sending of an A31 if set to 1
- N RESLT,CNT,MPI,EVN,TCNT,ERR,PD1,PID
- K HLA("HLA"),HLA("HLS")
- S CNT=1
- D INIT^HLFNC2("MPIF ADT-A24 SERVER",.HL)
- I $O(HL(""))="" Q "-1^"_$P(HL,"^",2)
- S HLECH=HL("ECH"),HLFS=HL("FS"),COMP=$E(HL("ECH"),1),REP=$E(HL("ECH"),2),SUBCOMP=$E(HL("ECH"),4)
- S ERR="",TCNT=0
- D BLDEVN^VAFCQRY(DFN,"1,2",.EVN,.HL,"A24",.ERR)
- Q:ERR'="" ERR
- D BLDPID^VAFCQRY(DFN,1,"ALL",.PID,.HL,.ERR)
- Q:ERR'="" ERR
- D BLDPD1^VAFCQRY(DFN,"3",.PD1,.HL,.ERR)
- Q:ERR'="" ERR
- I '$D(PID2) D BLDPID^VAFCQRY(DFN,2,"ALL",.PID2,.HL,.ERR) ;**43 TO ONLY BUILD 2ND PID SEGMENT IF NOT PASSED
- Q:ERR'="" ERR
- S HLA("HLS",1)=EVN(1)
- S HLA("HLS",3)=PD1(1)
- S CNT=0 F S CNT=$O(PID(CNT)) Q:CNT="" D
- .I CNT=1 S HLA("HLS",2)=PID(CNT)
- .I CNT>1 S HLA("HLS",2,CNT-1)=PID(CNT)
- S CNT=0 F S CNT=$O(PID2(CNT)) Q:CNT="" D
- .I CNT=1 S HLA("HLS",4)=PID2(CNT)
- .I CNT>1 S HLA("HLS",4,CNT-1)=PID2(CNT)
- S HLA("HLS",5)=$$EN1^VAFHLZPD(DFN,"1,17,21,34") ;25 ;**44 Adding Pseudo SSN Reason, 1 and 21 to ZPD segment
- K HLL("LINKS")
- D GENERATE^HLMA("MPIF ADT-A24 SERVER","LM",1,.MPIFRSLT,"","")
- S RESLT=$S(+MPIFRSLT:MPIFRSLT,1:"-1^"_$P(MPIFRSLT,"^",3)) ;**68 Story 827754 (jfw) - Make Error Data Consistent (-1^msg)
- ;**68 Story 827754 (jfw) - Check for value < 0 instead of '+RESLT
- I +RESLT<0 S ^XTMP("MPIFA24%"_DFN,0)=$$FMADD^XLFDT(DT,5)_"^"_DT_"^"_"A24 message to MPI for DFN "_DFN,^XTMP("MPIFA24%"_DFN,"MPI",0)="A"
- K HLA,HLEID,HLL("LINKS"),COMP,REP,SUBCOMP,HLECH,HLFS,HLA("HLA"),HLA("HLS"),MPIFRSLT
- ;**44 TRIGGER A31 TO UPDATE ANY DEMOGRAPHIC CHANGES
- ;**51 IF NOT SENDING A31 STOP PROCESSING
- I $G(NOA31)=1 Q RESLT
- N A31 S A31=$$A31^MPIFA31B(DFN)
- I +A31<0 D
- .;log exception about A31 not being sent
- .D START^RGHLLOG()
- .D EXC^RGHLLOG(208,$P(A31,"^",2)_" : Unable to generate A31 for DFN "_DFN,DFN) ;68, Story 827754 (jfw) - Combine error msgs as 1 param
- .D STOP^RGHLLOG(0)
- ;68, Story 827754 (jfw) - Remove redundancy as previously set in MPIFA31B.
- ;I $P(A31,"^",2)="" S ^XTMP("MPIFA31%"_DFN,0)=$$FMADD^XLFDT(DT,5)_"^"_DT_"^"_"A31 message to MPI for DFN "_DFN,^XTMP("MPIFA31%"_DFN,"MPI",0)="A"
- Q RESLT
- ;
- RT ;
- S MPI=$$MPILINK^MPIFAPI()
- I $P($G(MPI),"^")=-1 D START^RGHLLOG(),EXC^RGHLLOG(224,"No logical link defined for the MPI",$G(DFN)),STOP^RGHLLOG() Q
- ;**75 - Story - 1260465 (ckn) - Include 200M in HLL links for HAC
- S HLL("LINKS",1)="MPIF ADT-A24 CLIENT^"_MPI_$S($P($$SITE^VASITE(),"^",3)=741:"^200M",1:"")
- Q
- RES ;
- N NXT,DFN
- F NXT=1:1 X HLNEXT Q:HLQUIT'>0 D
- .I $E(HLNODE,1,3)="MSA" S DFN=$P($P(HLNODE,HL("FS"),7),"=",2)
- .I $E(HLNODE,1,3)="MSA"&($P(HLNODE,HL("FS"),4)'="") D
- ..; ERROR RETURNED IN MSA - LOG EXCEPTION --**44 stopped logging exception as MPI has already logged it.
- ..;D START^RGHLLOG(HLMTIEN,"","")
- ..;D EXC^RGHLLOG(208,$P(HLNODE,HL("FS"),4)_" for HL msg# "_HLMTIEN,DFN)
- ..;D STOP^RGHLLOG(0)
- K ^XTMP("MPIFA24%"_DFN)
- ;**61 Story 181213 (elz) let DG know A24 done
- K ^XTMP("DPTLK7 A24 IN-PROCESS",DFN)
- Q
- --- Routine Detail --- with STRUCTURED ROUTINE LISTING ---[H[J[2J[HMPIFA24B 3483 printed Feb 18, 2025@23:37:02 Page 2
- MPIFA24B ;BP/CMC-BUILD A24 ADD ME MSGS ; 5/4/20 10:59am
- +1 ;;1.0;MASTER PATIENT INDEX VISTA;**22,28,31,25,43,44,51,61,68,75**;30 Apr 99;Build 1
- +2 ;
- +3 ; Integration Agreements Utilized:
- +4 ; START, EXC, STOP^RGHLLOG - #2796
- +5 ; BLDEVN, BLDPD1, BLDPID^VAFCQRY - #3630
- +6 ;
- A24(DFN,PID2,NOA31) ;BUILD AND SEND A24 **43 added PID2 as a parameter - not required.
- +1 ; if PID2 is defined it will contain the previous ICN data, passed by reference
- +2 ; **51 ADDED NOA31 as a parameter to stop the sending of an A31 if set to 1
- +3 NEW RESLT,CNT,MPI,EVN,TCNT,ERR,PD1,PID
- +4 KILL HLA("HLA"),HLA("HLS")
- +5 SET CNT=1
- +6 DO INIT^HLFNC2("MPIF ADT-A24 SERVER",.HL)
- +7 IF $ORDER(HL(""))=""
- QUIT "-1^"_$PIECE(HL,"^",2)
- +8 SET HLECH=HL("ECH")
- SET HLFS=HL("FS")
- SET COMP=$EXTRACT(HL("ECH"),1)
- SET REP=$EXTRACT(HL("ECH"),2)
- SET SUBCOMP=$EXTRACT(HL("ECH"),4)
- +9 SET ERR=""
- SET TCNT=0
- +10 DO BLDEVN^VAFCQRY(DFN,"1,2",.EVN,.HL,"A24",.ERR)
- +11 if ERR'=""
- QUIT ERR
- +12 DO BLDPID^VAFCQRY(DFN,1,"ALL",.PID,.HL,.ERR)
- +13 if ERR'=""
- QUIT ERR
- +14 DO BLDPD1^VAFCQRY(DFN,"3",.PD1,.HL,.ERR)
- +15 if ERR'=""
- QUIT ERR
- +16 ;**43 TO ONLY BUILD 2ND PID SEGMENT IF NOT PASSED
- IF '$DATA(PID2)
- DO BLDPID^VAFCQRY(DFN,2,"ALL",.PID2,.HL,.ERR)
- +17 if ERR'=""
- QUIT ERR
- +18 SET HLA("HLS",1)=EVN(1)
- +19 SET HLA("HLS",3)=PD1(1)
- +20 SET CNT=0
- FOR
- SET CNT=$ORDER(PID(CNT))
- if CNT=""
- QUIT
- Begin DoDot:1
- +21 IF CNT=1
- SET HLA("HLS",2)=PID(CNT)
- +22 IF CNT>1
- SET HLA("HLS",2,CNT-1)=PID(CNT)
- End DoDot:1
- +23 SET CNT=0
- FOR
- SET CNT=$ORDER(PID2(CNT))
- if CNT=""
- QUIT
- Begin DoDot:1
- +24 IF CNT=1
- SET HLA("HLS",4)=PID2(CNT)
- +25 IF CNT>1
- SET HLA("HLS",4,CNT-1)=PID2(CNT)
- End DoDot:1
- +26 ;25 ;**44 Adding Pseudo SSN Reason, 1 and 21 to ZPD segment
- SET HLA("HLS",5)=$$EN1^VAFHLZPD(DFN,"1,17,21,34")
- +27 KILL HLL("LINKS")
- +28 DO GENERATE^HLMA("MPIF ADT-A24 SERVER","LM",1,.MPIFRSLT,"","")
- +29 ;**68 Story 827754 (jfw) - Make Error Data Consistent (-1^msg)
- SET RESLT=$SELECT(+MPIFRSLT:MPIFRSLT,1:"-1^"_$PIECE(MPIFRSLT,"^",3))
- +30 ;**68 Story 827754 (jfw) - Check for value < 0 instead of '+RESLT
- +31 IF +RESLT<0
- SET ^XTMP("MPIFA24%"_DFN,0)=$$FMADD^XLFDT(DT,5)_"^"_DT_"^"_"A24 message to MPI for DFN "_DFN
- SET ^XTMP("MPIFA24%"_DFN,"MPI",0)="A"
- +32 KILL HLA,HLEID,HLL("LINKS"),COMP,REP,SUBCOMP,HLECH,HLFS,HLA("HLA"),HLA("HLS"),MPIFRSLT
- +33 ;**44 TRIGGER A31 TO UPDATE ANY DEMOGRAPHIC CHANGES
- +34 ;**51 IF NOT SENDING A31 STOP PROCESSING
- +35 IF $GET(NOA31)=1
- QUIT RESLT
- +36 NEW A31
- SET A31=$$A31^MPIFA31B(DFN)
- +37 IF +A31<0
- Begin DoDot:1
- +38 ;log exception about A31 not being sent
- +39 DO START^RGHLLOG()
- +40 ;68, Story 827754 (jfw) - Combine error msgs as 1 param
- DO EXC^RGHLLOG(208,$PIECE(A31,"^",2)_" : Unable to generate A31 for DFN "_DFN,DFN)
- +41 DO STOP^RGHLLOG(0)
- End DoDot:1
- +42 ;68, Story 827754 (jfw) - Remove redundancy as previously set in MPIFA31B.
- +43 ;I $P(A31,"^",2)="" S ^XTMP("MPIFA31%"_DFN,0)=$$FMADD^XLFDT(DT,5)_"^"_DT_"^"_"A31 message to MPI for DFN "_DFN,^XTMP("MPIFA31%"_DFN,"MPI",0)="A"
- +44 QUIT RESLT
- +45 ;
- RT ;
- +1 SET MPI=$$MPILINK^MPIFAPI()
- +2 IF $PIECE($GET(MPI),"^")=-1
- DO START^RGHLLOG()
- DO EXC^RGHLLOG(224,"No logical link defined for the MPI",$GET(DFN))
- DO STOP^RGHLLOG()
- QUIT
- +3 ;**75 - Story - 1260465 (ckn) - Include 200M in HLL links for HAC
- +4 SET HLL("LINKS",1)="MPIF ADT-A24 CLIENT^"_MPI_$SELECT($PIECE($$SITE^VASITE(),"^",3)=741:"^200M",1:"")
- +5 QUIT
- RES ;
- +1 NEW NXT,DFN
- +2 FOR NXT=1:1
- XECUTE HLNEXT
- if HLQUIT'>0
- QUIT
- Begin DoDot:1
- +3 IF $EXTRACT(HLNODE,1,3)="MSA"
- SET DFN=$PIECE($PIECE(HLNODE,HL("FS"),7),"=",2)
- +4 IF $EXTRACT(HLNODE,1,3)="MSA"&($PIECE(HLNODE,HL("FS"),4)'="")
- Begin DoDot:2
- +5 ; ERROR RETURNED IN MSA - LOG EXCEPTION --**44 stopped logging exception as MPI has already logged it.
- +6 ;D START^RGHLLOG(HLMTIEN,"","")
- +7 ;D EXC^RGHLLOG(208,$P(HLNODE,HL("FS"),4)_" for HL msg# "_HLMTIEN,DFN)
- +8 ;D STOP^RGHLLOG(0)
- End DoDot:2
- End DoDot:1
- +9 KILL ^XTMP("MPIFA24%"_DFN)
- +10 ;**61 Story 181213 (elz) let DG know A24 done
- +11 KILL ^XTMP("DPTLK7 A24 IN-PROCESS",DFN)
- +12 QUIT