Home   Package List   Routine Alphabetical List   Global Alphabetical List   FileMan Files List   FileMan Sub-Files List   Package Component Lists   Package-Namespace Mapping  
Info |  Details
Print Page as PDF
Sub-Field: 691.921

Package: Medicine

ATRIAL STUDY(#691.9)-->691.921

Sub-Field: 691.921


Information

Parent File Name Number Package
ATRIAL STUDY(#691.9) BYPASS TRACT 691.921 Medicine

Details

Field # Name Loc Type Details
.01 BYPASS TRACT 0;1 SET
  • 'AV' FOR ATRIO-VENTRICULAR CONNECTION;
  • 'AH' FOR ATRIO-HISIAN TRACT;
  • 'AF' FOR ATRIO-FASCICULAR TRACT;
  • 'FV' FOR FASCICULO-VENTRICULAR TRACT;
  • 'NV' FOR NODO-VENTRICULAR TRACT;
  • 'NF' FOR NODO-FASCICULAR TRACT;

  • LAST EDITED:  OCT 07, 1987
  • DESCRIPTION:  
    This field identifies the bypass tract.
1 CONDUCTION 0;2 SET
  • 'A' FOR ANTEGRADE;
  • 'R' FOR RETROGRADE;
  • 'BI' FOR BIDIRECTIONAL;

  • LAST EDITED:  OCT 07, 1987
  • DESCRIPTION:  
    This allows the user to describe the bypass tract conduction.
2 ARRHYTHMIA 1;0 SET Multiple #691.9212 691.9212

  • DESCRIPTION:  
    This allows the user to further describe the type of arrhythmia.
3 SHORTEST PRE-EXCITED R-R A FIB 2;1 NUMBER

  • INPUT TRANSFORM:  K:+X'=X!(X>999)!(X<1)!(X?.E1"."1N.N) X
  • HELP-PROMPT:  Type the Number of Milliseconds between 1 and 999, 0 Decimal Digits
  • DESCRIPTION:  
    This allows the user to enter the shortest pre-excited R to R (atrial fibrillation) interval, measured in milliseconds.
4 SHORTEST R-R POST ISUPREL 2;2 NUMBER

  • INPUT TRANSFORM:  K:+X'=X!(X>999)!(X<0)!(X?.E1"."1N.N) X
  • HELP-PROMPT:  Type the Number of Milliseconds between 0 and 999, 0 Decimal Digits
  • DESCRIPTION:  
    This allows the user to enter the shortest pre-excited post isuprel, measured in milliseconds.
5 LOCATION OF TRACT 2;3 SET

  • LAST EDITED:  JUL 02, 1987
  • DESCRIPTION:  
    This allows the user to describe the location of tract.
6 V-HRA TIME 2;4 NUMBER

  • INPUT TRANSFORM:  K:+X'=X!(X>999)!(X<1)!(X?.E1"."1N.N) X
  • HELP-PROMPT:  Please enter conduction time from ventricle to high right atrium: Whole Number 1 to 999 (milliseconds)
  • DESCRIPTION:  
    This allows the user to enter the conduction time from ventricle to high right atrial.
7 ANTEGRADE ERP, BYPASS TRACT 2;5 NUMBER

  • INPUT TRANSFORM:  K:+X'=X!(X>999)!(X<0)!(X?.E1"."1N.N) X
  • HELP-PROMPT:  Type a Number between 0 and 999, 0 Decimal Digits
  • DESCRIPTION:  
    This allows the user to enter the effective refractory period, measured in milliseconds. This is the longest coupling interval which fails to conduct through the bypass tract, from A1 to A2.
8 ANTEGRADE ERP, BYPASS ISUPREL 2;6 NUMBER

  • INPUT TRANSFORM:  K:+X'=X!(X>999)!(X<0)!(X?.E1"."1N.N) X
  • HELP-PROMPT:  Type a Number between 0 and 999, 0 Decimal Digits
  • DESCRIPTION:  
    This allows the user to enter the effective refractory period, measured in milliseconds. This is the longest coupling interval which fails to conduct through the bypass isuprel, form A1 to A2.
9 RETROGRADE ERP, BYPASS TRACT 2;7 NUMBER

  • INPUT TRANSFORM:  K:+X'=X!(X>999)!(X<0)!(X?.E1"."1N.N) X
  • HELP-PROMPT:  Type a Number between 0 and 999, 0 Decimal Digits
  • DESCRIPTION:  
    This allows the user to enter the longest coupling interval which fails to conduct through the bypass tract.
10 RETROGRADE ERP, BYPASS ISUPREL 2;8 NUMBER

  • INPUT TRANSFORM:  K:+X'=X!(X>999)!(X<0)!(X?.E1"."1N.N) X
  • HELP-PROMPT:  Type a Number between 0 and 999, 0 Decimal Digits
  • DESCRIPTION:  
    This allows the user to enter the longest coupling interval which fails to conduct through the bypass isuprel.
Info |  Details