Sub-Field: 700.018

Package: Medicine

PULMONARY FUNCTION TESTS(#700)-->700.018

Sub-Field: 700.018


Information

Parent File Name Number Package
PULMONARY FUNCTION TESTS(#700) FLOWS STUDY 700.018 Medicine

Details

Field # Name Loc Type Details
.01 FLOWS STUDY 0;1 SET
  • 'S' FOR STANDARD STUDY;
  • 'B' FOR AFTER BRONCHODILATORS;
  • 'I' FOR AFTER INHALATION CHALLENGE;
  • 'X' FOR AFTER EXERCISE;

  • LAST EDITED:  SEP 12, 1991
  • HELP-PROMPT:  Enter the type of Flows Study done: Use 'S' for study without or prior to use of inhaled or administered agent, or before exercise
  • DESCRIPTION:  
    This field identifies the type of Flow Study performed.
  • TECHNICAL DESCR:  
    ORDER ENTRY TYPE: UNKNOWN
  • CROSS-REFERENCE:  700.018^B
    1)= S ^MCAR(700,DA(1),4,"B",$E(X,1,30),DA)=""
    2)= K ^MCAR(700,DA(1),4,"B",$E(X,1,30),DA)
  • CROSS-REFERENCE:  700^AF^MUMPS
    1)= S ^MCAR(700,"AF",$P(^MCAR(700,DA(1),0),U,2),X,9999999.9999-$P(^MCAR(700,DA(1),0),U),DA(1),DA)=""
    2)= K ^MCAR(700,"AF",$P(^MCAR(700,DA(1),0),U,2),X,9999999.9999-$P(^MCAR(700,DA(1),0),U),DA(1),DA)
    This cross-reference indexes the date and time of the most recent flows study of this type for this pulmonary function test.
1 FVC 0;2 NUMBER

  • INPUT TRANSFORM:  K:+X'=X!(X>9.99)!(X<.05)!(X?.E1"."3N.N) X
  • LAST EDITED:  FEB 28, 1990
  • HELP-PROMPT:  Enter the Forced Vital Capacity (FVC) measured for this study in LITERS: .05-9.99
  • DESCRIPTION:  
    This field identifies the measured Forced Vital Capacity.
  • TECHNICAL DESCR:  
    ORDER ENTRY TYPE: UNKNOWN
2 FEV1 0;3 NUMBER

  • INPUT TRANSFORM:  K:+X'=X!(X>99.99)!(X<.05)!(X?.E1"."3N.N) X
  • LAST EDITED:  APR 20, 1990
  • HELP-PROMPT:  Enter the Forced Expired Volume in Liters: .05-99.99, 2 Decimal Digits
  • DESCRIPTION:  
    This field identifies the measured Forced Expired Volume in 1 second
  • TECHNICAL DESCR:  
    ORDER ENTRY TYPE: UNKNOWN
3 PF 0;4 NUMBER

  • INPUT TRANSFORM:  K:+X'=X!(X>20)!(X<0)!(X?.E1"."4N.N) X
  • LAST EDITED:  SEP 12, 1991
  • HELP-PROMPT:  Enter the Peak Expiratory Flow in Liters/Sec: 0-20, 3 decimal places.
  • DESCRIPTION:  
    This field identifies the measured Peak Flow.
4 FEF25-75 0;5 NUMBER

  • INPUT TRANSFORM:  K:+X'=X!(X>25)!(X<0)!(X?.E1"."4N.N) X
  • LAST EDITED:  SEP 12, 1991
  • HELP-PROMPT:  Enter the Forced Expiratory Flow from 25 to 75 percent in Liters/Sec: 0-25, 3 Decimal Digits
  • DESCRIPTION:  
    This field identifies the measured Forced Expired Flow from 25 to 75 percent.
5 FEV1/FVC COMPUTED

  • MUMPS CODE:  S Y(700.018,5,1)=$S($D(^MCAR(700,D0,4,D1,0)):^(0),1:"") S X=$P(Y(700.018,5,1),U,3),X=$S($P(Y(700.018,5,1),U,2):X/$P(Y(700.018,5,1),U,2),1:"*******")*100 S X=$J(X,0,0)
  • ALGORITHM:  FEV1/FVC*100 (ALWAYS 0 DECIMAL DIGITS)
  • DESCRIPTION:  
    This computed field is the Forced Expired Volume divided by the Forced Vital capacity.
5.5 MVV 0;7 NUMBER

  • INPUT TRANSFORM:  K:+X'=X!(X>200)!(X<0)!(X?.E1"."1N.N) X
  • LAST EDITED:  SEP 17, 1991
  • HELP-PROMPT:  Enter the Maximum Voluntary Ventilation in Liters/Minute: 0-200
  • DESCRIPTION:  
    This field identifies the Maximum Voluntary Ventilation in Liters/Minute
  • TECHNICAL DESCR:  
    ORDER ENTRY TYPE: UNKNOWN
6 NOTES 0;6 FREE TEXT

  • INPUT TRANSFORM:  K:$L(X)>60!($L(X)<2) X
  • LAST EDITED:  FEB 28, 1990
  • HELP-PROMPT:  Enter notes on this study.
  • DESCRIPTION:  
    This field identifies allows the entering of a note (up to 60 characters) on this Flow Study.
Info |  Details