+---------------------------------------------------------------+ | | | Property of the US Government. | | No permission to copy or redistribute this software is given. | | Use of unreleased versions of this software requires the user | | to execute a written test agreement with the VistA Imaging | | Development Office of the Department of Veterans Affairs, | | telephone (301) 734-0100. | | | | The Food and Drug Administration classifies this software as | | a medical device. As such, it may not be changed in any way. | | Modifications to this software may result in an adulterated | | medical device under 21CFR820, the use of which is considered | | to be a violation of US Federal Statutes. | | | +---------------------------------------------------------------+ The routing software is able to transmit image files from the VistA system where the images are stored permanently to various destinations that may receive temporary copies of images. Files can be transmitted to these destinations using several protocols. Valid destinations for files that are transmitted using the MS-DOS copy protocol are stored in the Network Location table (FileMan file #2005.2). Valid destinations for files that are transmitted using the DICOM C-Store protocol are stored in this file. For each destination, this table contains the identifying information for the destinations, as well as the identifying information for the DICOM Gateways that are allowed to transmit images to these destinations. If multiple DICOM Gateways are allowed to transmit images to a specific destination, this table will contain multiple entries for that destination, one for each source and destination pair.
HELP-PROMPT: Enter the Application Entity Title of the Service Class Provider.
DESCRIPTION:
The value of this field is a string that specifies the Application Entity Title for the equipment being called for the application that is described in the current entry.
INPUT TRANSFORM: K:+X'=X!(X>65535)!(X<1)!(X?.E1"."1N.N) X
LAST EDITED: MAY 14, 2003
HELP-PROMPT: Enter the port number for the Service Class Provider.
DESCRIPTION:
The value of this field is an integer number that identifies the TCP/IP port number to which the equipment connects calls the application that is described in this entry.
HELP-PROMPT: Enter the Application Entity Title of the DICOM Gateway
DESCRIPTION:
The value of this field is a string that specifies the Application Entity Title for the VistA DICOM Gatewat from which the application is called that is described in the current entry.