Home   Package List   Routine Alphabetical List   Global Alphabetical List   FileMan Files List   FileMan Sub-Files List   Package Component Lists   Package-Namespace Mapping  
Info |  Details
Print Page as PDF
Sub-Field: 853.013

Package: VA Point of Service

VPS CONFIG HISTORY(#853)-->853.01-->853.013

Sub-Field: 853.013


Information

Parent File Name Number Package
853.01 MR INCOMPLETE REASON TYPE 853.013 VA Point of Service

Details

Field # Name Loc Type Details
.01 MR INCOMPLETE REASON TYPE 0;1 SET

  • INPUT TRANSFORM:  S DINUM=X Q
  • LAST EDITED:  MAY 10, 2013
  • HELP-PROMPT:  Choose MR Incomplete Reason Type.
  • DESCRIPTION:  This field contains description of reason why MR module couldn't be completed.
    The MR Incomplete Reason Type is one of the following: 1. The MR module could not be started because patient arrived TOO EARLY, TOO LATE, or NOT EARLY ENOUGH at the device. 2. Either the patient walked away in the
    middle of the Medication Review or the TIME LIMIT AR COMPLETE time expired. 3. The patient selected to exit the Medication Review. 4. The patient selected to bypass the Medication Review. 5. Service failure of
    VetLink at the site.
    See TIME LIMIT TOO LATE ARRIVAL, TIME LIMIT TOO EARLY ARRIVAL, and TIME LIMIT NOT EARLY ENOUGH fields for definition of TOO LATE, TOO EARLY, and NOT EARLY ENOUGH.
  • NOTES:  XXXX--CAN'T BE ALTERED EXCEPT BY PROGRAMMER
  • CROSS-REFERENCE:  853.013^B
    1)= S ^VPS(853,DA(2),"PARAM",DA(1),"MRREASON","B",$E(X,1,30),DA)=""
    2)= K ^VPS(853,DA(2),"PARAM",DA(1),"MRREASON","B",$E(X,1,30),DA)
    This cross reference is for VPS CONFIG History MR INCOMPLETE REASON TYPE look up.
1 LOW USE THRESHOLD MR 0;2 NUMBER

  • INPUT TRANSFORM:  K:+X'=X!(X>100)!(X<0)!(X?.E1"."3N.N) X
  • LAST EDITED:  JAN 08, 2015
  • HELP-PROMPT:  Type a number between 0 and 100, 2 decimal digits.
  • DESCRIPTION:  This is the percentage number that the system will use to monitor an acceptable level of MR non-completion. The acceptable level is determined by measuring this number against the mean number of MR non-completions
    for an MR incomplete reason type. e.g., out of 100 patient MR non-completions, 15 patients decide to bypass the review thus the mean number for this reason type is 15% and if the Low Use Threshold MR is set to 10%,
    the system will detect an unacceptable level of MR non-completions when too many patients are by-passing review.
Info |  Details