All ICR List

Package: Imaging ICR List

IA # Name Type Custodial Package Date Created DBIC Approval Status Status Usage File # General Description Remote Procedure Routine Date Activated
IA # Name Type Custodial Package Date Created DBIC Approval Status Status Usage File # General Description Remote Procedure Routine Date Activated
458 DBIA458 Routine IMAGING 1994/04/25 APPROVED Active Private
MailMan 7.1 is permitted to the make calls to MAGAPI routine in the imaging
package:
MAGAPI
459 DBIA459 File IMAGING 1994/04/25 APPROVED Active Private 2005
This agreement describes data that MailMan can access from the imaging
package.
460 DBIA460 File IMAGING 1994/04/25 APPROVED Active Private 2005.2
MailMan has permission to access file 2005.2 so that it can find where images
are and record their position appropriately.
461 DBIA461 File IMAGING 1994/04/25 APPROVED Active Private 2005.02
Before an image can be displayed, the type of file it is stored in must be
known.
462 DBIA462 Routine IMAGING 1994/05/03 APPROVED Active Private
MailMan has permission to call MAGAPI for 3 purposes.
MAGAPI
463 DBIA463 Routine IMAGING 1994/05/03 APPROVED Active Private
MailMan has permission to call MAGBAPI so that images
that are imported can be moved into a permanent storage location.
MAGBAPI
464 DBIA464 Routine IMAGING 1994/04/25 APPROVED Active Private
MailMan has permission to call MAGOBJ in order to display an image on a screen
while a user is reading a message.
MAGOBJ
466 DBIA466 Routine IMAGING 2003/10/20 Retired Private
The Medicine package has been given permission by the
Imaging package to do the following:
Make calls to the ^MAGMIM routine through the ^MCMAG routine.
MAGMIM
467 DBIA467 Routine IMAGING 2003/10/20 Retired Private
The Medicine package has been given permission by the
Imaging package to do the following:
Make calls to the ^MAGDISP routine through the ^MCMAG routine.
MAGDISP
468 DBIA468 Routine IMAGING 2003/10/20 Retired Private
The Medicine package has been given permission by the
Imaging package to the following:
Make calls to the ^MAGSUM routine through the ^MCMAG routine.
MAGSUM
469 DBIA469 Other IMAGING 2003/10/20 Retired Private
The Medicine package has permission by the Imaging
package to Kill the ^TMP("MAG",$J,"COL") and ^TMP("MAG",$J,"ROW") globals
within the Medicine package upon exiting the Summary of Patient Procedures
options.
470 DBIA470 File IMAGING 2003/10/20 APPROVED Active Private 2005
The Medicine package has been given permission by the
Imaging package to do the following:
Point to the Imaging File (#2005) to reference each Medicine Procedure that
has images.
1196 IMAGING/SURGERY MAGSRIC Routine IMAGING 1995/04/13 APPROVED Active Private
The Surgery Package is given permission to call
IM^MAGSRIC to provide image capture capability to users of the operations
options
MAGSRIC
1202 MAGING/SURGERY CLEANUP Routine IMAGING 1995/04/21 APPROVED Active Private
The Surgery Package is given permission to call
CLEAN^MAGSRIC to kill MAG namespaced local variables on exit from routine(s)
using IM^MAGSRIC for image capture.
MAGSRIC
1324 DBIA1324-A File IMAGING 1995/08/25 APPROVED Active Private 2005
This DBIA documents Radiology/Nuclear Medicine's use of
a global node belonging to the Imaging package to determine whether the
Imaging package has been installed at a given facility.
1325 DBIA1324-B File IMAGING 1995/08/25 APPROVED Active Private 2005
This DBIA documents Radiology/Nuclear Medicine's use of
a global node owned by the Imaging package to determine if images are scanned
in before a reports are entered.
1326 DBIA1324-C Routine IMAGING 1995/08/25 APPROVED Active Private
This DBIA documents a line label reference within the
Radiology/Nuclear Medicine package to a routine in the Imaging package.
MAGSET3
1328 DBIA1324-E Routine IMAGING 1995/08/25 APPROVED Active Private
This DBIA documents a Radiology/Nuclear Medicine
package reference to a line label within the Imaging package.
MAGRIC
1338 DBIA1338 Other IMAGING 1995/09/12 APPROVED Active Private
This DBIA documents that Radiology/Nuclear Medicine
kills two ^TMP( nodes for the Imaging package. The global nodes are:
^TMP("MAG",$J,"ROW")
^TMP("MAG",$J,"COL") This is necessary to reset the abstract display screen
so the next abstract display will begin in the upper left hand corner of the
screen. Only the Radiology/Nuclear Medicine package knows when the current
case processing is finished, which is the point where these nodes must be
killed.
2791 DBIA2791 File IMAGING 1999/03/31 Withdrawn Private 2005
Imaging gives permission to Health Summary to read from
file 2005 for the purpose of displaying image descriptions. [MAGI]
2927 POINTERS TO IMAGE FILE (#2005) File IMAGING 1999/10/14 APPROVED Active Controlled Subscription 2005
To support many-to-many linkages between Images (stored
in file #2005) and other patient-oriented data (e.g., Documents, Orders,
Reports, etc.) the subscribing packages may retain POINTERS to file 2005.
3567 Imaging - MAGGSIUI Routine IMAGING 2002/04/26 APPROVED Active Controlled Subscription
Imaging v3.0 patch MAG*3.0*7 introduces an Image Import
API that can be used to automatically import image files into VistA Imaging.
The image files can be from a medical device (instrument) or a network or
local drive. Once image files are imported, they are available for display
from the VistA Imaging Clinical Display application.
Importing image/report files is a two step process:
Step 1: The calling program initiates the import proces by sending an input
array to the Import API. The import API uses the input array to create an
entry in the Import Queue file and returns a status array to the calling
program.
Step 2: After the entries in the Import Queue file are processed (by the
Background Processor residing on the network), the Import API reports back to
the calling program in a result array.
Note: The Import API, as part of the VistA Imaging software, is regulated as
a medical device. The Import API cannot be used without a written agreement
between the VistA Imaging SD&D group and the party wishing to use the Import
API.
To secure an agreement for the use of the Import API, the following criteria
must be met:
1) Any products built or interfaced using the VistA Imaging Import API
must be tested with VistA Imaging. Testing will be performed by the VistA
Imaging team with assistance from field sites and the calling package. This
testing must demonstrate that there are no adverse interactions affecting the
safety, efficacy or performance of the VistA Imaging software or the devices
interfaced to VistA Imaging.
2) Any changes to packages/product(s) using the VistA Imaging Import API
must be reported to the VistA Imaging Project Office for review and testing
before release. Retesting of VistA Imaging with the product(s) is required
with any change.
3) Documentation that imported reports/objects meet VHA, regulatory, and
quality requirements must be on file with the Vista Imaging Project Office
prior to any clinical use. Sample imported reports/objects shall be provided
initially to the VistA Imaging Project Office by the package using the API.
Sites installing the VistA Imaging API must comply with all VistA Imaging
requirements and are responsible for filing all required documentation with
the VistA Imaging Project Office, including image quality and data forms and
sample reports/objects from any interfaced device.
4) Additional requirements may apply to non-VA software using the Import
API.
MAGGSIUI
4009 File 2005 File IMAGING 2003/03/18 Withdrawn Private 2005
4526 MAG4 REMOTE IMPORT Remote Procedure IMAGING 2004/10/29 APPROVED Active Controlled Subscription
MAG4 REMOTE IMPORT This RPC is used to QUEUE an image
for storage by the VistA Imaging Import API.
MAG4 REMOTE IMPORT
4528 MAG IMPORT CHECK STATUS Remote Procedure IMAGING 2004/10/29 APPROVED Active Controlled Subscription
MAG IMPORT CHECK STATUS This RPC is called to get a
status record from the IMPORT STATUS file (2006.037)
MAG IMPORT CHECK STATUS
4529 IMAGING RPC Remote Procedure IMAGING 2004/10/26 APPROVED Active Controlled Subscription
MAG IMPORT CLEAR STATUS This RPC call will remove a
status record in the IMPORT STATUS file (2006.037).
4530 MAG IMPORT CLEAR STATUS Remote Procedure IMAGING 2004/10/29 APPROVED Active Controlled Subscription
MAG IMPORT CLEAR STATUS This RPC will be used to clear
a status record from the IMPORT STATUS file (2006.037).
MAG IMPORT CLEAR STATUS
4588 Imaging's API for CP Routine IMAGING 2005/01/11 APPROVED Active Private
Imaging grants Clinical Procedures permission to call
routine MAGMC2CP.
MAGMC2CP
4838 4838 MAGDTR01 Routine IMAGING 2006/03/31 APPROVED Active Controlled Subscription
Imaging has requested Consults to add a call,
ORRIN^MAGDTR01 to the routine GMRCIMSG for use with patch MAG*3.0*46. This
will allow Imaging to process Consult HL7 messages.
MAGDTR01
4845 Return NEW PERSON file phone number(s) Routine IMAGING 2006/04/12 APPROVED Active Private
The Vista Radiology/Nuclear Medicine application would
like to utilize the existing VistA Imaging utility (NPFON^MAG7UFO) to return
all phone number related information for a specific record in the NEW PERSON
(#200) file.
MAG7UFO
4973 Creation of a HL7 PID & PV1 segments (V2.4) Routine IMAGING 2007/04/23 Withdrawn Private
The VistA Imaging development team will provide a
function that creates both PID & PV1 segments that are backwards compatible to
version 2.4 of Health Level Seven (HL7). The PID & PV1 segments are fixed
segments; the Imaging development team will determine the fields to be defined
for these segments in accordance with the 'Integrating the Healthcare
Enterprise Radiology Technical Framework' specifications for order (ORM)
transactions.
MAGDHLS
4977 Creation of a HL7 PID segment (V2.4) Routine IMAGING 2007/02/15 Withdrawn Private
The VistA Imaging development team will provide a
function that creates a PID segment that is backwards compatible to version
2.4 of Health Level Seven (HL7). The PID segment is a fixed segment; the
Imaging development team will determine the fields to be defined for this
segment in accordance with the 'Integrating the Healthcare Enterprise
Radiology Technical Framework' specifications for order (ORM) transactions.
MAGDHLS
5021 Populate NEW PERSON phone(s) into a local array Routine IMAGING 2007/08/01 Active Private
This function return the following NEW PERSON (#200)
file fields into a local array: PHONE (HOME) (#.131), OFFICE PHONE (#.132),
PHONE #3 (#.133), PHONE #4 (#.134), COMMERCIAL PHONE (#.135), FAX NUMBER
(#.136), VOICE PAGER (#.137), and DIGITAL PAGER (#.138).
MAG7UFO
5022 Build the HL7 ZDS segment for Study Instance UID Routine IMAGING 2007/08/01 Active Private
This function creates a DICOM Study Instance UID from
three Radiology/Nuclear Medicine package variables: RADTI, RACNI, and RADTE.
MAGDRAHL
5023 Build the HL7 PID and PV1 segments Routine IMAGING 2007/08/01 Active Private MAGDHLS
5291 DSIV IMAGING ACCESS File IMAGING 2008/11/23 APPROVED Active Private 2005
The DSIV package is requsting use of the "ATRKID" cross
reference to get the image IEN in the Image file (#2005) of an image that is
has imported using the Import API. The IEN is stored in an SQL database and
also verifies that the scanned document, or other image, was successfully
uploaded to imaging. The DocManager piece of DSIV has been tested by VistA
Imaging.
Note: DSIV also uses ICR 4526 (MAG4 REMOTE IMPORT) RPC from Imaging. The use
of the MAG4 REMOTE IMPORT RPC and access to the "ATRKID" cross reference is
limited to the DSS DocManager application only. Any other DSIV application
will need approval before using the RPC or cross reference.
2009/06/11
5450 KERNEL BSE LOOKUP IN NETWORK LOCATION FILE File IMAGING 2009/05/12 APPROVED Active Private 2005.2
Kernel Broker Security Enhancement (BSE) requests the
ability to do a lookup within the NETWORK LOCATION file (#2005.2) using
FileManager and the command
D FIND^DIC(2005.2,,"1","MO","VISTASITESERVICE",,,,,"XUSBSE")
2010/06/16
5556 MAG4 DATA FROM IMPORT QUEUE Remote Procedure IMAGING 2010/08/27 Pending Controlled Subscription
This call returns the Array of Data from the Import
Queue, given a QUEUE Number. Can be called from Delphi and 'M'.
MAG4 DATA FROM IMPORT QUEUE
5557 MAG4 INDEX GET EVENT Remote Procedure IMAGING 2010/08/27 Pending Controlled Subscription
This call will return an array of entries from the
IMAGE INDEX FOR PROCEDURE/EVENT (#2005.85) file based on the input parameters
CLS (Class) and SPEC (Specialty/subspecialty). When images are displayed, it
is desirable to limit the list of presented images to only those that are
likely to be relevant in the current context.
This procedure accepts an "image category" (either an IEN or the name of a
category) and returns all "image events" that belong to that category.
5558 MAG4 INDEX GET ORIGIN Remote Procedure IMAGING 2010/08/27 Pending Controlled Subscription
This call will return an array of the ORIGIN INDEX
(field #45) from the IMAGE (#2005) file. The result array includes all ORIGIN
codes and abbreviations.
5559 MAG4 INDEX GET SPECIALTY Remote Procedure IMAGING 2010/08/27 Pending Controlled Subscription
This call will return an array of entries from the
IMAGE INDEX FOR SPECIALTY/SUBSPECIALTY (#2005.84) file based on the input
parameters CLS (Class) and EVENT (Procedure/Event). When images are displayed,
it is desirable to limit the list of presented images to only those that are
likely to be relevant in the current context.
This procedure accepts an "image category" (either an IEN or the name of a
category) and returns all "(sub)specialties" that generate images in that
category.
5560 MAG4 INDEX GET TYPE Remote Procedure IMAGING 2010/08/27 Pending Controlled Subscription
Used to filter out those image types that belong to a
given image category (Class). When images are displayed, it is desirable to
limit the list of presented images to only those that are likely to be
relevant in the current context.
This procedure accepts an "image class" (either an IEN or the name of a class)
and returns all "image types" that belong to that class.
5561 MAGN PATIENT HAS PHOTO Remote Procedure IMAGING 2010/08/27 Pending Controlled Subscription
Checks if photo image exists for a patient. Returns 0
if no photo or the date/time (Fileman format) of the most recent photo.
5562 MAG4 GET SUPPORTED EXTENSIONS Remote Procedure IMAGING 2010/08/27 Pending Controlled Subscription
Returns a list of supported file extensions used in
Imaging from the IMAGE FILE TYPES (#2005.021) file.
MAG4 GET SUPPORTED EXTENSIONS
5563 MAG3 CPRS TIU NOTE Remote Procedure IMAGING 2010/08/27 Pending Controlled Subscription
Returns a list of all images for a TIU document.
MAG3 CPRS TIU NOTE
5564 MAGG CAPTURE USERS Remote Procedure IMAGING 2010/08/27 Pending Controlled Subscription
This call will find users that have captured images in
a date range. The list of users can be filtered by the FLAGS parameter. The
Flags Parameter can contain 'C' for images captured on the Capture Workstation
and/or 'I' for images captured throught the Import API. If the parameter is
null it defaults to 'CI'.
5565 IMAGING QUEUE STATUS Routine IMAGING 2010/08/27 Pending Controlled Subscription
This API will return the imaging queue status based on
a Queue Number or Tracking ID.
S X=$$STATUS^MAGQBUT3(Queue Number)
S X=$$STATUS^MAGQBUT3(Tracking ID)
MAGQBUT3
5568 IMAGE INDEX FOR CLASS file 2005.82 File IMAGING 2010/09/08 Pending Controlled Subscription 2005.82
The MAG4 INDEX GET TYPE remote procedure requires a
Class parameter. The IMAGE INDEX FOR CLASS file (#2005.82) contains the list
of available class types for imaging and will be read using FileMan.
^MAG(2005.82,D0,0)
.01 NAME 0;1 Read with Fileman
5628 CHECK FOR MAGDISP CLIN KEY File IMAGING 2011/04/15 APPROVED Active Private
This ICR allows the subscribing package(s) to check for
the MAGDISP CLIN key using the ^XUSEC global. Reference ICR 10076 for more
information on the XUSEC global.
2011/05/03
5730 MAG RESCIND IMAGES Routine IMAGING 2011/10/05 APPROVED Active Private
This ICR will allow the TIU Package to set a Queue so
that Images attached to a Rescinded Advance Directive will be Watermarked with
the word 'RESCINDED'.
MAGGSIU4 2011/10/14
5994 DBIA5994 Routine IMAGING 2013/07/29 APPROVED Active Private
VistA Imaging gives permission to Laboratory Package to
call CANCEL^MAGT7MA, EDIT^MAGT7MA, NEW^MAGT7MA, REPORT^MAGT7MA . These calls
create VistA Imaging HL7 DICOM PACS messages pertain to Anatomic Pathology
order updates. The messages are stored in PACS MESSAGE file (#2006.5) and are
processed by VistA Imaging DICOM Text gateway.
MAGT7MA 2013/09/27
5997 DBA5997 Routine IMAGING 2013/07/30 APPROVED Active Private
VistA Imaging gives permission to Laboratory Package to
call ADD^MAGTP005
MAGTP005 2013/09/20
6000 MAGV GET IRRADIATION DOSE Routine IMAGING 2013/07/31 APPROVED Active Private
The TAG^ROUTINE documented will return the attributes
for the irradiation instance related to the patient and the procedure.
MAGVRD03 2013/08/14
6159 MAG4 ADD IMAGE Remote Procedure IMAGING 2015/02/18 Withdrawn Controlled Subscription MAG4 ADD IMAGE
6160 MAG3 TIU IMAGE Remote Procedure IMAGING 2015/02/18 Withdrawn Controlled Subscription MAG3 TIU IMAGE
6161 MAG4 IMAGE LIST Remote Procedure IMAGING 2015/02/18 Withdrawn Controlled Subscription
6162 MAGBAPIP Routine IMAGING 2015/02/18 APPROVED Active Controlled Subscription MAGBAPIP 2015/04/03
6163 MAGBAPI Routine IMAGING 2015/02/18 APPROVED Active Controlled Subscription MAGBAPI 2015/04/03
6192 MAG 2005 READ File IMAGING 2015/04/17 APPROVED Active Controlled Subscription 2005
This ICR provides for the FileMan read of the
^MAG(2005, "ATRKID" index in the IMAGE FILE (#2005) and the PATIENT field #5
in the IMAGE FILE (#2005).
These fields provide the ability to associate an image to a patient when a
callback is execued by the Imaging Background Processor which passes only the
Tracking ID and Queue ID to the callback routine. Once the IEN of the image
entry in found using "ATRKID", the patient can be identified by reading fieled
# in ^MAG(2005,D0,0).
2015/04/21
6353 SCHEDULING BSE LOOKUP IN NETWORK LOCATION FILE File IMAGING 2016/02/08 APPROVED Active Private 2005.2
VistA Scheduling GUI Enhancement (VS GUI) patch
SD*5.3*642 requests the ability to do a lookup of the PHYSICAL REFERENCE field
#1 within the NETWORK LOCATION file (#2005.2) using FileManager. This value
will be passed back to VS GUI in order to obtain values to support Single Sign
On (SSO) using the Broker Security Enhancement (BSE) lookup.
2016/03/07
6379 VA Community Care Access to Imaging Other IMAGING 2016/03/01 Withdrawn Private
Responsibility for processing VA Community Care (VACC)
claims has changed from the VISNs/VAMCs to the Chief Business Office for
Purchased Care (CBOPC). As a national program, staff members often require
access to multiple VistA systems in order to perform their duties. Four new
menus are being created for use as a primary menu in accessing remote VistA
systems via CAPRI. VACC staff need to be able to access Imaging in support of
processing claims.
6732 VISTA IMAGING RAD DOSE DATABASE ACCESS File IMAGING 2017/02/07 APPROVED Active Private 2005.632
VistA Radiology/Nuclear Medicine requires VA FileMan
(FM) read/with FM and direct global read access to the CT DOSE (#2005.632)
file.
The direct global read will be used to determine the presence of data in file
2005.632.
2017/07/11
6733 VISTA IMAGING RAD DOSE DATABASE ACCESS (2) File IMAGING 2017/02/07 APPROVED Active Private 2005.633
VistA Radiology/Nuclear Medicine requires VA FileMan
(FM) read/with FM and direct global read access to the PROJECTION X-RAY DOSE
(#2005.633) file.
The direct global read will be used to determine the presence of data in file
2005.633.
2017/07/11
6761 Update patient demographics via HL7 w/VI Routine IMAGING 2017/05/18 APPROVED Active Private
VistA Imaging provides a routine type entry point that
will build and broadcast HL7 ADT A08 Patient Information Update messages to
subscribers of ADT messages.
A HL7 ADT A47 Change Patient Identifier List message will also be built and
broadcast for each SSN change.
MAGDHLE 2017/09/14
6860 MAG IHE SWITCH FOR HL7 ADT MESSAGES File IMAGING 2017/12/19 Under Revision Private 2006.1
Radiology requests access to the IMAGING SITE
PARAMETERS file (#2006.1), field IHE PACS HL7 INTERFACE ACTIVE (#3.01) to
determine if the broadcast of ADT messages are permitted at a facility. ADT
messages can be broadcast by running the new RA ADT menu option that will be
available with patch RA*5.0*137.
2017/12/21
6910 BUILD VI HL7 ORM MESSAGE FOR CP CHECK-IN OR CANCELLATION Routine IMAGING 2018/04/30 Pending Private
VistA Imaging's (MAG) CLINPROC^MAGDHOWP is called by
MDHL7BH to build and broadcast VistA Imaging HL7 ORM (order) messages for a
check-in or cancellation events in the Clinical Procedure (MD) application.
MAGDHOWP
6911 SWAP CP INSTRUMENT ORDER # w/ IMAGING CONSULT ACCESSION # Routine IMAGING 2018/04/30 Pending Private
VistA Imaging software has been enhanced to replace the
CP Instrument Order Number with the VistA Imaging consults Accession Number.
This greatly improves interoperability between Clinical Procedures and VistA
Imaging CPRS Consult Request Tracking.
MAGDFCNV
6931 CP DICOM INTEROPERABILITY RETURN SSAN FOR CLIN SPEC Routine IMAGING 2018/06/15 APPROVED Active Private
This extrinsic function will return a site-specific
accession number for clinical specialties. GMRCIEN is the CPRS Consult Request
Tracking GMRC IEN from the REQUEST/CONSULTATION file (#123).
MAGDFCNV 2018/06/15
6932 CP DICOM INTEROPERABILITY BUILD HL7 MESSAGE Routine IMAGING 2018/06/15 APPROVED Active Private
This API builds the VistA Imaging procedure HL7 ORM
(order) message using the VistA Imaging formatted accession number. The API
may conditionally return the HL7 ORM message body for Clinical Procedures'
use.
MAGDHOWP 2018/06/15
6959 CP CONVERSION UTILITY File IMAGING 2018/09/07 APPROVED Active Private 2006.5831
Clinical Procedures requires read access to the
CLINICAL SPECIALTY DICOM & HL7 file (#2006.5831) to screen for consults or
procedures setup in DICOM. The screen is on the interactive lookup for
consults or procedures that are being selected to convert to Clinical
Procedures.
2018/12/03
7253 OEHRM Imaging Migration - Access to file #2006.5839 File IMAGING 2021/05/04 Pending Private 2006.5839
OEHRM is creating Imaging Migration software to
facilitate the transfer of images from VistA to Millennium. The software will
build a central accession number database that identifies all image-holding
entities - consults and Radiology procedures - and will maintain that file
throughout the conversion period.
7254 OEHRM Imaging Migration - Access to file #2005 File IMAGING 2021/05/04 APPROVED Active Private 2005
OEHRM is creating Imaging Migration software to
facilitate the transfer of images from VistA to Millennium. The software will
build a central accession number database that identifies all image-holding
entities - consults and Radiology procedures - and will maintain that file
throughout the conversion period.
Note: The patch - EHM*1*2 - will not be installed nationally. It will be
installed only at sites that are being converted to Cerner.
2021/06/15
7255 OEHRM Imaging Migration - Access to file #2005.61 File IMAGING 2021/05/04 Pending Private 2005.61
OEHRM is creating Imaging Migration software to
facilitate the transfer of images from VistA to Millennium. The software will
build a central accession number database that identifies all image-holding
entities - consults and Radiology procedures - and will maintain that file
throughout the conversion period.
7267 OEHRM Imaging Migration - Access to file #2005.62 File IMAGING 2021/06/01 Pending Private 2005.62
OEHRM is creating Imaging Migration software to
facilitate the transfer of images from VistA to Millennium. The software will
build a central accession number database that identifies all image-holding
entities - consults and Radiology procedures - and will maintain that file
throughout the conversion period.
Note: The patch - EHM*1*2 - will not be installed nationally. It will be
installed on at sites that are being converted to Cerner.
7270 OEHRM Imaging Migration - Access to file #2005.63 File IMAGING 2021/06/15 Pending Private 2005.63
OEHRM is creating Imaging Migration software to
facilitate the transfer of images from VistA to Millennium. The software will
build a central accession number database that identifies all image-holding
entities - consults and Radiology procedures - and will maintain that file
throughout the conversion period.
7408 MAG RAD LIST DATA ELEMENTS (#2006.63) File IMAGING 2023/01/05 APPROVED Active Private 2006.63
The ISI Rad CLIENT application is a plug-in replacement
for VistA Imaging's VistARad client. ISI Rad uses all of the existing VistA
Imaging SERVER software (RPC calls, routines, files, etc.) in the same way as
VistARad. In some cases, to support new features that VistARad does not have,
new ISI SERVER software uses many of the same subroutines and files in the
same manner as VistARad: session initialization; fetching Exam info and Image
info; Exam Locking; Exam List data management; etc.
VistA Imaging gives permission to ISI Rad to read and update file MAG RAD LIST
DATA ELEMENTS (#2006.63), which contains data necessary for the exam list
subsystem used by VistARad.
2023/03/07
7409 MAG RAD LISTS DEFINITION (#2006.631) File IMAGING 2023/01/05 APPROVED Active Private 2006.631
The ISI Rad CLIENT application is a plug-in replacement
for VistA Imaging's VistARad client. ISI Rad uses all of the existing VistA
Imaging SERVER software (RPC calls, routines, files, etc.) in the same way as
VistARad. In some cases, to support new features that VistARad does not have,
new ISI SERVER software uses many of the same subroutines and files in the
same manner as VistARad: session initialization; fetching Exam info and Image
info; Exam Locking; Exam List data management; etc.
VistA Imaging gives permission to ISI Imaging to read and update file MAG RAD
LISTS DEFINITION (#2006.631), which contains Exams List specification data for
the exam list subsystem used by VistARad.
2023/03/07
7410 MAG VISTARAD SITE PARAMETERS (#2006.69) File IMAGING 2023/01/05 APPROVED Active Private 2006.69
The ISI Rad CLIENT application is a plug-in replacement
for VistA Imaging's VistARad client. ISI Rad uses all of the existing VistA
Imaging SERVER software (RPC calls, routines, files, etc.) in the same way as
VistARad. In some cases, to support new features that VistARad does not have,
new ISI SERVER software uses many of the same subroutines and files in the
same manner as VistARad: session initialization; fetching Exam info and Image
info; Exam Locking; Exam List data management; etc.
VistA Imaging gives permission to ISI Imaging to read and update file MAG
VISTARAD SITE PARAMETERS (#2006.69), which contains control data for managing
various logic switches in VistARad (e.g., enable/disable a feature).
2023/03/07
7497 Call MAGT7MA For LAB Data From File 63 Routine IMAGING 2024/09/27 Active Controlled Subscription
MEDICOM TECHNOLOGIES requests to call $$GETFILE^MAGT7MA
to get LABORATORY TEST file (#60) data, determine the error status of the lab
and return FILE("FIELD") fields for the LAB DATA file (#63).
MAGT7MA
7501 Get Lab Test Data Routine IMAGING 2024/10/10 Active Controlled Subscription
The routine creates the OBR segment for HL7 message to
DPS and provides a lookup for Lab Test
MAGT7SB
7504 DICOM Patient Lookup Routine IMAGING 2024/10/22 Active Controlled Subscription
API's and RPC'S for VistA PATIENT lookup routine
MAGDSTA3
7505 Setup Rad/Nuc Med HL7 Output Array Separators Routine IMAGING 2024/11/04 Active Controlled Subscription
Patch MECH*1.0*1 gathers patient cases to send to the
ImageX Application via HL7 messages. This patch calls $$OUTSEP^MAGVIM01 and
$$STATSEP^MAGVIM01 to get the correct separators for the HL7 messages.
MAGVIM01